Payment Terms | T/T, L/C, D/A, D/P, Western Union |
Supply Ability | 2000 sets per month |
Delivery Time | 10-15 days |
Packaging Details | carton / wooden case |
Power supply | 24VDC, 100-240VAC, 12-36VDC |
Accuracy | 0.5% linear, 0.25%FS to 0.5%FS |
Product name | Electromagnetic flowmeter |
Type | Integral converter |
Liquid media | conductive liquid, water |
Output | 4-20 mA, Pulse |
Communication | Modbus RS485 |
Connection | Flange, thread, insert |
Brand Name | Runpaq |
Model Number | YE-E50 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Flange Thermal Mass Electromagnetic Water Flow Meter PN16 15m/S
Electromagnetic 316L Electrode Thermal Mass Flow Meter RS485 Communication
Seawater Electromagnetic Water Flow Meter With Rubber Liner
316L Electrode PTFE Liner Wastewater Flow Meter With Flanges Port
Product Specification
Payment Terms | T/T, L/C, D/A, D/P, Western Union | Supply Ability | 2000 sets per month |
Delivery Time | 10-15 days | Packaging Details | carton / wooden case |
Power supply | 24VDC, 100-240VAC, 12-36VDC | Accuracy | 0.5% linear, 0.25%FS to 0.5%FS |
Product name | Electromagnetic flowmeter | Type | Integral converter |
Liquid media | conductive liquid, water | Output | 4-20 mA, Pulse |
Communication | Modbus RS485 | Connection | Flange, thread, insert |
Brand Name | Runpaq | Model Number | YE-E50 |
Certification | CE | Place of Origin | China |
High Light | 24VDC electromagnetic water meter ,flanged electromagnetic water meter ,Electromagnetic Flowmeter |
Industrial Electromagnetic flow meter/ wastewater flow meter liner hard rubber
Description
The flanged electromagnetic flowmeter for use in volumetric measurement of conductive fluid, like municipal or industrial water and waste water applications in which propeller meters have typically been used in the past.
Features
Details demonstration
Inhouse PCB production Silicon steel transformer Calibration line
Technical data
Product name | Electromagnetic flowmeter | ||
Product type | Local|compact display | Remote display | Signal converter |
Model | IYF-E | IYF-F | IRT |
Pipe Diameter (mm) | DN10-DN2000 | ||
Power supply | 100-240 VAC / 18-36 VDC | ||
Accuracy | + 0.5% | + 0.5% | + 0.5% |
Power consumption | <6w | <6w | <6w |
Enclosure rating | IP65 | IP68 | IP65 |
Liquid temperature | -25-120℃ | -25-120℃ | -25-120℃ |
Ambient temperature | -25-50℃ | -25-50℃ | -25-50℃ |
Relative humidity | 10-90% | 10-90% | 10-90% |
Meter ratio | 1:100 | 1:100 | 1:100 |
Flow direction | Bi-direction flow | Bi-direction flow | Bi-direction flow |
Communication | RS485 / Bacnet | RS485 / Bacnet | RS485 / Bacnet |
Signal Output | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency |
Accuracy
Pipe Dia (mm) | Velocity (m/s) | Accuracy |
3-20 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout | |
25-600 | 0.1-0.3 | + 0.25% FS |
0.3-1 | + 0.5% Readout | |
1-15 | + 0.3% Readout | |
700-3000 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout |
Model selection
Notice on the selection of local type and remote type:
Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
remote type in the following conditions:
No | Model | ||||||||
YF | Electromagnetic flowmeter | ||||||||
TF | Turbine | ||||||||
VF | Votex | ||||||||
LX | Vane wheel | ||||||||
T | Ultrasonic | ||||||||
E/F display mode | E: compact/local display, F: remote display | ||||||||
Pipe Dia | Type (mm) | ||||||||
xxxx | 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1000 | ||||||||
Code | Accuracy | ||||||||
1 | + 0.5% FS | ||||||||
2 | + 1.0% FS | ||||||||
3 | + 0.2% FS | ||||||||
Code | Type | ||||||||
N | Converter: 12 / 24 VDC, pulse output | ||||||||
A | Transmitter: 24VDC, 4-20mA outpt | ||||||||
B | Intelligent, Lion battery, no local display | ||||||||
G | Smart, local display, 4-20mA output | ||||||||
C1 | Smart, local display, RS485 | ||||||||
C2 | Smart, local display, HART | ||||||||
Code | Type | ||||||||
S | Carbon steel housing | ||||||||
L | Stainless steel housing | ||||||||
G | High pressure housing | ||||||||
HL | 316L electrode | ||||||||
HTi | Titanium electrode | ||||||||
HTa | Tantlum electrode | ||||||||
HC | Hastelloy-C electrode | ||||||||
L1 | Liquid media | ||||||||
L2 | Gas media | ||||||||
P | Pressure compensation | ||||||||
T | Temperature compensation | ||||||||
PT | Pressure&Temp. Compensation | ||||||||
F | PTFE liner | ||||||||
X | Rubber liner | ||||||||
Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner |
Applicable metering liquid:
Non-applicable metering medial
Pipe Diameter, flow volume and product dimension
Dia | Flow volume (m3/h) | Product dimension (mm) | |||||
(mm) | Normal | Min | Max | L | D | H | H1 |
15 | 1.5 | 0.06 | 9.5 | 150 | 95 | 272 | 254 |
20 | 2.5 | 0.11 | 16.9 | 105 | 277 | 254 | |
25 | 3.5 | 0.18 | 26.5 | 115 | 283 | 254 | |
32 | 6 | 0.29 | 43.6 | 140 | 297 | 270 | |
40 | 10 | 0.45 | 67.8 | 150 | 307 | 280 | |
50 | 15 | 0.71 | 106.0 | 200 | 165 | 318 | 294 |
65 | 25 | 1.19 | 179.1 | 185 | 337 | 313 | |
80 | 40 | 1.81 | 271.4 | 200 | 352 | 326 | |
100 | 60 | 2.83 | 424.1 | 250 | 220 | 371 | 344 |
125 | 100 | 4.42 | 665 | 250 | 401 | 372 | |
150 | 135 | 6.36 | 954 | 300 | 285 | 431 | 403 |
200 | 250 | 11.3 | 1696 | 350 | 340 | 486 | 460 |
250 | 375 | 17.66 | 2650 | 400 | 395 | 547 | 511 |
300 | 540 | 25.43 | 3817 | 450 | 445 | 597 | 565 |
350 | 735 | 34.62 | 5195 | 505 | 657 | 620 | |
400 | 960 | 45.22 | 6785 | 500 | 565 | 717 | 675 |
450 | 1200 | 57.23 | 8588 | 550 | 615 | 757 | 727 |
500 | 1500 | 70 | 10602 | 600 | 670 | 817 | 782 |
600 | 2160 | 100 | 15268 | 780 | 917 | 782 | |
700 | 2950 | 138 | 20781 | 700 | 895 | 1027 | 1068 |
800 | 3850 | 180 | 27100 | 800 | 1015 | 1137 | 1157 |
Industrial applications
Chemical | Food & beverage | Paper mill |
Metallurgy | Environment protection | Hydraulic |
Mining | Stainless | Petroleum |
Pharmacy | Air conditioner | Effluent treatment plant |
Seawater desalination | Pharmacy | Water treatment |
Competitive advantage
Company Details
Business Type:
Manufacturer,Agent
Year Established:
2009
Total Annual:
30000000-50000000
Employee Number:
100~200
Ecer Certification:
Active Member
We're a national key high-tech enterprise serving in fields of new energy management system and equipment, main services include: HVAC central air-conditioning and cold storage, solar distributed energy & regional energy, flow & energy management. We have integrative certification of ... We're a national key high-tech enterprise serving in fields of new energy management system and equipment, main services include: HVAC central air-conditioning and cold storage, solar distributed energy & regional energy, flow & energy management. We have integrative certification of ...
Get in touch with us
Leave a Message, we will call you back quickly!