China factories

China factory - Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

  • China,Beijing ,Beijing
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China 10KV Electrical Industrial Current Transformers -25°C - 55°C Operating Temp
China 10KV Electrical Industrial Current Transformers -25°C - 55°C Operating Temp

  1. China 10KV Electrical Industrial Current Transformers -25°C - 55°C Operating Temp

10KV Electrical Industrial Current Transformers -25°C - 55°C Operating Temp

  1. MOQ: 3 PCS
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 10000 PCS/MONTH
Delivery Time 2-3 weeks
Packaging Details Standard Export Carton Box
Name Mid Voltage 10KV Instrument Current Transformer Cast Resin Dry Type
Rated primary current 5-1000A
Rated load ≤15VA
Rated insulation level 12/42/75KV
FS ≤10
Weight 22Kg
Brand Name GFUVE
Model Number GFLZZ0944-10
Certification CE, UL, KEMA, ISO9001
Place of Origin BEIJING CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 10000 PCS/MONTH
Delivery Time 2-3 weeks Packaging Details Standard Export Carton Box
Name Mid Voltage 10KV Instrument Current Transformer Cast Resin Dry Type Rated primary current 5-1000A
Rated load ≤15VA Rated insulation level 12/42/75KV
FS ≤10 Weight 22Kg
Brand Name GFUVE Model Number GFLZZ0944-10
Certification CE, UL, KEMA, ISO9001 Place of Origin BEIJING CHINA
High Light electromagnetic potential transformerpower potential transformer

 

Mid Voltage 10KV Instrument Current Transformer Cast Resin Dry Type

 

 

Introduction

 

Instrument transformers are high accuracy class electrical devices used to isolate or transform voltage or current levels. The most common usage of instrument transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. The primary winding of the transformer is connected to the high voltage or high current circuit, and the meter or relay is connected to the secondary circuit.
Instrument transformers may also be used as an isolation transformer so that secondary quantities may be used in phase shifting without affecting other primary connected devices.
Current transformers (CT) are a series connected type of instrument transformer. They are designed to present negligible load to the supply being measured and have an accurate current ratio and phase relationship to enable accurate secondary connected metering.
Current transformers are often constructed by passing a single primary turn (either an insulated cable or an uninsulated bus bar) through a well-insulated toroidal core wrapped with many turns of wire. This affords easy implementation on high voltage bushings of grid transformers and other devices by installing the secondary turn core inside high-voltage bushing insulators and using the pass-through conductor as a single turn primary.


 

PARAMETERS

 

Technical parameters  
Standards IEC60044; IEC 61869; ANSI/IEEE C57.13
Rated primary current 5-1000A
Rated load ≤15VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 63kA, 1S
Rated dynamic current 130kA
Rated insulation level 12/42/75KV
FS ≤10
Mechanical parameters  
Material Epoxy resin
Weight (kg) 22
Operating conditions  
Operating temperature -25°C to +55°C
Daily average temp <+40°C
Storage temperature -40°C to +70°C
Altitude <1000 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.


 

 

TECHNICAL PARAMETERS

 

Ratied Primary Current(A) Class Combination Accuracy class and Rated output
(VA)
Short-time thermal current
(kA/S)
Rated dynamic current
(kA)
0.2(S) 0.5 10P10
5-50 0.2(S)/10P10
0.5/10P10
10 10 15 400I1n 1000I1n
75 32 100
100-500 45 100
600-1000 63 130
1250-1500 80 160
500-1000 0.2(S)/0.5/10P10 63 130

 

 

 

 

Overall Dimensions

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    $100,000,000-$150,000,000

  • Employee Number:

    300~350

  • Ecer Certification:

    Active Member

Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core... Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
  • Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
  • https://www.zerosequencecurrenttransformer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement