China factories

China factory - Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

  • China,Beijing ,Beijing
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Harmonics Measurement Portable Meter Test Equipment 380V
China Harmonics Measurement Portable Meter Test Equipment 380V

  1. China Harmonics Measurement Portable Meter Test Equipment 380V
  2. China Harmonics Measurement Portable Meter Test Equipment 380V

Harmonics Measurement Portable Meter Test Equipment 380V

  1. MOQ: 1SET
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 200sets/month
Delivery Time 2weeks
Packaging Details Standard Export Wooden Box
Name Portable Meter Three Phase Test Equipment
Application energy meter & power meter calibrator
Usage lab and factory
Accuracy 0.05%
Function 0.05% voltage source & current source
Current Output 0-120A
Voltage Output 0-380V
Frequency 45-65Hz
Phase Angle 0-360.00
LCD 7 inch touch TFT color LCD
Harmonics 2-51nd
Weight 25KG
Brand Name GFUVE
Model Number GF302D1-100A
Certification CE, ISO9001
Place of Origin BEIJING CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 200sets/month
Delivery Time 2weeks Packaging Details Standard Export Wooden Box
Name Portable Meter Three Phase Test Equipment Application energy meter & power meter calibrator
Usage lab and factory Accuracy 0.05%
Function 0.05% voltage source & current source Current Output 0-120A
Voltage Output 0-380V Frequency 45-65Hz
Phase Angle 0-360.00 LCD 7 inch touch TFT color LCD
Harmonics 2-51nd Weight 25KG
Brand Name GFUVE Model Number GF302D1-100A
Certification CE, ISO9001 Place of Origin BEIJING CHINA
High Light 120A Portable Meter Test Equipment380V Portable Meter Test Equipment65Hz Portable Meter Test Equipment

 
GF302D1 100A 380V Portable Three Phase Meter Test Equipment With Scanning head and harmonics measurement
 
GFUVE is a leading manufacturer of three phase portable meter test equipment for electricity meters and energy meter testing and calibration in China, we supply stationary or portable test equipment, power sources, reference standards, calibrators.
 
The GF302D1 three phase portable kWh meter test equipment consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7” touch LCD-display.
 
GF302D1 portable test equipment adopts mature signal synthetic and advance power amplifier technology, wide voltage and current output with high efficiency and high stability, to be widely used in lab and field.

APPLICATION

 
It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and the production of enterprise etc.

Nation-level utility companies
Governmental bureaus of metrology
Energy meter manufacturer

FEATURES

 

  • To set up and take the load regulation of voltage, current, phase angle ,frequency and power factor etc; as a large current source, voltage source and power source
  • To set 2 ~ 51 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output
  • Voltage, current output a wide range, big power, high stability, waveform distortion degree is small
  • Strong with load ability, but it can take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01%
  • To apply the 32 bit MPU + DSP + CPLD, powerful flexible
  • To use hardware PID, fast response, the change of load will not cause output volatility
  • Industrial frequency waves as high as 5000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small
  • Range switching automatically
  • To use software calibration, simple operation, stable and reliable
  • Display of vector diagram, adjustable to IEC387 OR DIN410, IEC60736
  • Big touch screen, 7-inch TFT color LCD display, English interface, operating simply
  • To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, failure detection automatically
  • With RS232 interface, and PC connection
  • To take place machine software, it can be output through the PC software program

 

PARAMETERS

 

Electrical parameters 
Accuracy class 0.02%, 0.05%, 0.1%
Power supply Single phase AC 85-265 V, frequency 50/60 Hz
AC Voltage output 
Range (U1, U2, U3 phase) 57.7V/100V/220V/380V; range switch automatically(Max 500V)
Adjust fineness 0.01% RG
Accuracy 0.05% RG, 0.02% RG
Stability <0.01% RG/120s
Distortion degree <0.3% (not capacitive load)
Output power 25VA
Full load regulation rate 0.01% RG
Full load regulation time Less than 1mS
Long-term stability ± 60 PPM/year
AC Current output 
Range (I1, I2, I3 phase) 0.2A, 1A, 5A, 20A, 100A; range switch automatically
Adjustment range (0-120)%RG
Adjust fineness 0.01% RG
Accuracy 0.05% RG, 0.02% RG
Stability <0.01% RG/120s
Distortion degree <0.3% (not capacitive load)
Output power 45VA
Full load regulation rate 0.01% RG
Full load regulation time Less than 1mS
Long-term stability ± 60 PPM/year
Power output 
Accuracy 0.05% RG, 0.02% RG
Stability 0.01% RG/120s
Phase angle 
Adjusting range 0°-359.99°
Resolution 0.001°
Accuracy 0.05°, 0.02°
Power factor  
Adjusting range -1 ~ 0 ~ +1
Resolution 0.0001
Accuracy 0.0005
Frequency 
Adjusting range 40-65 Hz
Resolution 0.001 Hz
Accuracy 0.005 Hz, 0.001 Hz
Temperature drift ± 0.5 PPM/°C
Long-term stability ± 4 PPM/year
Harmonic accuracy 
Harmonic phase 0°-359.99°
Harmonic phase accuracy < 0.01°
Harmonic set accuracy 0.1% (relative to the base wave ratings)
Mechanical parameters 
Dimensions (W×D×H) (mm) 500x600x175
Weight (kg) 25
Environmental conditions 
Working temperature 0°C to 40°C
Storage condition -30°C to -60°C
Relative humidity ≤ 85%

 

SELECTION GUIDE

 

NO. Accuracy Voltage range Current Range Weight
302D1201 0.10% 0-500V 0-120A 27KG
302D12005 0.05% 0-500V 0-120A 27KG
302D1201 0.10% 0-380V 0-12A 18KG
302D1205 0.05% 0-380V 0-12A 18KG
302D2401 0.10% 0-500V 0-24A 20KG
302D2405 0.05% 0-500V 0-24A 20KG

Photo

0.05°

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    $100,000,000-$150,000,000

  • Employee Number:

    300~350

  • Ecer Certification:

    Active Member

Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core... Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
  • Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
  • https://www.zerosequencecurrenttransformer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement