China ABB Schneider Siemens Protection Relay Test Equipment
China ABB Schneider Siemens Protection Relay Test Equipment

  1. China ABB Schneider Siemens Protection Relay Test Equipment
  2. China ABB Schneider Siemens Protection Relay Test Equipment

ABB Schneider Siemens Protection Relay Test Equipment

  1. MOQ: 1SET
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 200SETS/MONTH
Delivery Time 3 DAYS
Packaging Details STANDARD EXPORT WOODEN BOX
PRODUCT NAME auto six phase protective relay test equipment
ACCURACY 0.1%
Application ABB, Schneider & Siemens protection relay device
FUNCTION1 overload & overvoltage relay test
FUNCTION2 Distance protection
U/I RANGE 0-60A/0-300V AC/DC
LCD color 8.4 inch
WEIGHT 16.6KG
Test method Auto
Brand Name GFUVE
Model Number TEST-630 60a/300v
Certification CNAS, CE, ISO9001
Place of Origin BEIJING CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 200SETS/MONTH
Delivery Time 3 DAYS Packaging Details STANDARD EXPORT WOODEN BOX
PRODUCT NAME auto six phase protective relay test equipment ACCURACY 0.1%
Application ABB, Schneider & Siemens protection relay device FUNCTION1 overload & overvoltage relay test
FUNCTION2 Distance protection U/I RANGE 0-60A/0-300V AC/DC
LCD color 8.4 inch WEIGHT 16.6KG
Test method Auto Brand Name GFUVE
Model Number TEST-630 60a/300v Certification CNAS, CE, ISO9001
Place of Origin BEIJING CHINA
High Light Siemens Protection Relay Test EquipmentABB Protection Relay Test EquipmentSchneider Protection Relay Test Equipment

TEST-630 portable auto six phase protective relay test equipment for ABB, Schneider & Siemens protection relay device

 

 

The proper operation of the protective relays is critical in the reliability and safety of power systems, protecting other devices from damage and helping to the system security. Accordingly, the testing of relays is required during the installation and commissioning process, and as part of the maintenance programs throughout its service life.
Protection testing. Protection systems play a key role for the safe and reliable operation of today’s electricity power systems. Properly working protection devices help to maintain the safety of the system and to safeguard assets from damage. In order to ensure reliable operation, protective relays as well as recloser controls must be tested throughout their life-cycle, from their initial development through
Protection systems play a key role for the safe and reliable operation of today’s electricity power systems. Properly working protection devices help to maintain the safety of the system and to safeguard assets from damage. In order to ensure reliable operation, protective relays as well as recloser controls must be tested throughout their life-cycle, from their initial development through production and commissioning to periodical maintenance during operation.
Our test equipment is ideal for each of these life-cycle phases and for any environment. As a reliable long-term partner, we offer state-of-the-art testing solutions which are continuously being developed and maintained to help you to keep pace with the increasingly complex requirements of your systems.
Relays testing may range from a simple check of some points of the relay characteristic to a complete verification of the protection scheme logic, even including the response to transient waveforms, harmonics, etc
TEST-630 is designed with fuse on the mains supply and electronic protection for overload on the current (open circuit) or voltage outputs(short circuit), with immediate isolation of the output and alarm indication. Also diagnostic message for the setting of wrong data, mistakes on the input etc. There's also electronic protection in case of counter-feed of voltage output, if any incorrectness happen, the alarm light shall flash. And Overheat LED indicator shall flash for Protection against over-temperature, on all outputs.Universal testing system TEST-630 (6×35A, 6×300V) can test all types of protective relays, including modern IEC61850 based relays. Other test works, such as transducer, energy meter, indication meter, etc., can also be done easily. It's the ideal test
device for all power utilities, power plants, relay manufactures, panel manufactures, research institutes, Universalities, testing
companies, etc.
 
Differential
is suitable for use the 6 output current channels' relay tester, which is applied on transformer, generator and bus bar etc. differential protection equipment test. Because of adopting the 6 currents output, it realizes the two sides three phases test between relay tester and relay equipment.
Inverse time overcurrent
This module realizes the directional over-current test and non-directional over-current test. This module also include: testing positive sequence, negative sequence and zero sequence instantaneous time over-current,
over-heat protection inverse time over-current or the customized “Current/Time” operation characteristic.

TEST ITEM

  • U/I test
  • DC test
  • Impedance characteristics
  • Power direction test
  • I-T test
  • Differential relay
  • Harmonic test
  • Differential protection
  • Distance protection
  • Zero sequence protection
  • Setting group test
  • State sequence
  • Synchronization test
  • Special test
  • Oscillation test
  • Metering instrument
  • Hardware checkout
  • Low Voltage protection
  • Fault Recurrence

 

 

PARAMETERS

Electrical parameters
Power voltage AC220V±10% or AC110V±10%, 50/60Hz±10%
Time measurement 0.1ms-999999.999s
AC current output 
Phase current output (effective value) 6 x 0-30A
Maximum power output 260VA/phase
Maximum parallel current output (effective value) 0-180A
Long-term allowable working value of phase current
(effective value)
>10A
Allowable working time of maximum current >11s
Accuracy class <±0.1%
AC voltage output 
Phase voltage output (effective value) 6 x 0-130V
Line voltage output (effective value) 0-260V
Maximum power output 70VA/phase
Accuracy class <±0.1%
DC current output 
Output range -10 to 10A or 3 x 0 to ±10A
Maximum power output 200VA
Accuracy class <±0.1%
DC voltage output 
Output range 0-300V or 5 x 0 to ±130V
Maximum output power 130VA
Accuracy class <±0.1%
Binary input 
Idle contact 1-20mA, 24V (DC)
Electric potential contact 250V/0.5A (DC)
Binary output 
Idle contact 250V/0.5A (DC)
Rated output 
Frequency error <±0.01Hz
Phase error <±0.1°
Waveform distortion <±0.3% (fundamental wave)
Time error <40µs
Output frequency 0-1050Hz
Superposed harmonic wave 0-21times

PHOTO

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    $100,000,000-$150,000,000

  • Employee Number:

    300~350

  • Ecer Certification:

    Active Member

Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core... Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
  • Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
  • https://www.zerosequencecurrenttransformer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement