China factories

China factory - Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

  • China,Beijing ,Beijing
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Single Power Source Electrical Test Equipment Clamp Type Multimeter Calibrator
China Single Power Source Electrical Test Equipment Clamp Type Multimeter Calibrator

  1. China Single Power Source Electrical Test Equipment Clamp Type Multimeter Calibrator
  2. China Single Power Source Electrical Test Equipment Clamp Type Multimeter Calibrator
  3. China Single Power Source Electrical Test Equipment Clamp Type Multimeter Calibrator
  4. China Single Power Source Electrical Test Equipment Clamp Type Multimeter Calibrator

Single Power Source Electrical Test Equipment Clamp Type Multimeter Calibrator

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 500
Delivery Time 1-2Week
Packaging Details Standard Wooden Case
Power supply Single phase AC 220V±10% or 110V±10%, 50/60HzAC
AC Current range 200mV, 400mV, 2000mV, 4000mV, 20V, 100V, 200V, 500V, 1000V
AC Voltage Range 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A
Range 45-65Hz
Fineness 0.001Hz
Times 2-31
Extent 0-20%
Brand Name GFUVE
Model Number GF6018A
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 500
Delivery Time 1-2Week Packaging Details Standard Wooden Case
Power supply Single phase AC 220V±10% or 110V±10%, 50/60HzAC AC Current range 200mV, 400mV, 2000mV, 4000mV, 20V, 100V, 200V, 500V, 1000V
AC Voltage Range 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A Range 45-65Hz
Fineness 0.001Hz Times 2-31
Extent 0-20% Brand Name GFUVE
Model Number GF6018A Place of Origin China
High Light electronic test instrumentselectronic measurement equipment

Clamp Type Multimeter Calibrator GF6018A

 

The equipment is compliance with national verification regulation: JJG124-2005 “Ammeter, voltmeter, power meter and resistance meter verification rules” and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.

 

 

FEATURES

  • It can be semi-automatic or manual inspection of analog multi meter, clamp type current meter, all kinds of electric meter, (voltmeter, ammeter, frequency meters, resistance meter) basic error
  • The equipment can be generated with 2-31 harmonic wave, harmonic number, order, amplitude and harmonic phase of fundamental wave can be programmed
  • Power amplifier working frequency range is 40Hz-1KHZ, has a good linear. Current amplifier is constant current source; voltage amplifier is constant voltage source. Because of light weight, this device is more suitable for field use
  • With RS-232 interface, this device is controlled by PC through the PC software (optional), can be automatic or manual inspection, and the results are processing and management
  • Has a non-volatile memory, it can store 500 pieces of the raw data of tested meter, for access and upload
    Electrical parameters  
    Power supply Single phase AC 220V±10% or 110V±10%, 50/60HzAC
    AC Voltage output  
    range 200mV, 400mV, 2000mV, 4000mV,
    20V, 100V, 200V, 500V, 1000V
    Range 20V-1000V Accuracy ±(0.03%RD+0.02%FS)
    Stability ≤0.01% FS /60s
    Range 200mV-4000mV Accuracy ±(0.3%RD+0.2%FS)
    Stability ≤0.04% FS /60s
    Load capacity 20VA
    Waveform distortion ≤0.3%
    Adjustable Range 0-120% FS (1000V not included)
    Fineness 5×10-5
    AC Current Output  
    Range 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A
    Range 0.2A-20A Accuracy ±(0.03%RD+0.02%FS)
    Stability ≤0.01% FS /60s
    Range 2mA-40mA Accuracy ±(0.3%RD+0.2%FS)
    Stability ≤0.04% FS /60s
    Load capacity 20VA
    Waveform distortion ≤0.3%
    Adjustable Range 0-120% FS
    Fineness 5×10-5
    Frequency Output  
    Range 45-65Hz
    Fineness 0.001Hz
    Accuracy 0.01Hz
    Harmonic Wave  
    Times 2-31
    Extent 0-20%
    Each harmonic phase fineness 0.01·N (N is harmonic order)
    DC voltage output  
    Range 200mV, 400mV, 2000mV, 4000mV,
    20V, 40V, 100V, 200V, 400V, 1000V
    Load capacity 20W
    Adjustable range 0-110% FS (1000V not included)
    Adjustable fineness 5×10-5
    Stability ≤0.01% FS /60s (peak-peak value)
    Accuracy ±(0.03%RD+0.02%FS)
    Ripple wave ≤1% FS
    DC current output  
    Range 20uA, 40uA, 200uA, 400uA, 2mA, 4mA,
    20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A
    Load capacity 20W
    Adjustable Range 0-110% FS (1000V not included)
    Adjustable Fineness 5×10-5
    Stability ≤0.01% FS /60s (peak-peak value)
    Accuracy ±(0.06%RD+0.04%FS)
    Ripple wave ≤1% FS
    Resistance box  
    Range 0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ,
    0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ
    Fineness 0.02%
    Range 0-2kΩ, 0-20kΩ, 0-200kΩ  
    Range 0-2kΩ Adjustable Range 0-100%FS
    Accuracy ±(0.12%RD+0.08%FS)
    Range 0-200Ω,0-2MΩ Adjustable Range 0-100% FS
    Accuracy ±(0.3%RD+0.2%FS)
    Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ  
    Range 2kΩ-4kΩ Adjustable Range 5%-100%FS
    Accuracy ±(0.12%RD+0.08%FS)
    Range 200-400Ω,
    2MΩ-4MΩ
    Adjustable Range 5%-100% FS
    Accuracy ±(0.3%RD+0.2%FS)
    Clamp meter range  
    200A Accuracy ±0.2%
    600A Accuracy ±0.5%
    1000A Accuracy ±1%
    Dot frequency square wave output 
    Range 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz
    Square wave amplitude 4.5V
    Setting accuracy 5×10-5
    Mechanical parameters  
    Dimension (L×W×H) (mm) 440x360x160
    Weight (kg) 12
    Environmental conditions 
    Operating temperature 20°C±10°C
    Relative humidity ≤85%RH

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    $100,000,000-$150,000,000

  • Employee Number:

    300~350

  • Ecer Certification:

    Active Member

Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core... Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
  • Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
  • https://www.zerosequencecurrenttransformer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!