Payment Terms | T/T, Western Union, MoneyGram |
Supply Ability | 1500SETS/MONTH |
Delivery Time | 1-2WEEKS |
Packaging Details | CARTON |
accuracy | 0.05%, 0.1% |
display | 6”TFT (640×480) |
power supply | 220V±10%, 50/60Hz |
communication port | RS232 |
voltage test range | Phase to Netural 0-480V (Phase to Phase 0-830V) |
harmonic | 2nd-64st |
current test range | 0-12A |
frequency | 40-70Hz |
dimension | 245×162×60mm |
weight | 1.8kg |
Brand Name | GFUVE |
Model Number | GF312D1 |
Place of Origin | BEIJING,CHINA |
View Detail Information
Explore similar products
Handheld 480V Energy Meter Tester 45Hz Kwh Meter Test Equipment
1P2W Harmonic 40Hz Kwh Meter Test Equipment Self Checking
500V Manual Keyboard Electric Meter Calibration 70Hz Overload Protection
Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter
Product Specification
Payment Terms | T/T, Western Union, MoneyGram | Supply Ability | 1500SETS/MONTH |
Delivery Time | 1-2WEEKS | Packaging Details | CARTON |
accuracy | 0.05%, 0.1% | display | 6”TFT (640×480) |
power supply | 220V±10%, 50/60Hz | communication port | RS232 |
voltage test range | Phase to Netural 0-480V (Phase to Phase 0-830V) | harmonic | 2nd-64st |
current test range | 0-12A | frequency | 40-70Hz |
dimension | 245×162×60mm | weight | 1.8kg |
Brand Name | GFUVE | Model Number | GF312D1 |
Place of Origin | BEIJING,CHINA | ||
High Light | 2nd Harmonic Electricity Meter Calibrator ,RS232 TFT Electric Meter Calibration ,70Hz Harmonic Electricity Meter Calibrator |
FEATURES
TECHNICAL PARAMETERS
1.Electrical parameters | |
---|---|
Accuracy class | 0.05%, 0.1% |
Display | 6”TFT (640×480) |
Power supply | 220V±10%, 50/60Hz Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh) Power line supply (U1, UN), 85V-265V 50/60Hz |
Communication port | RS232 |
Test voltage | |
Range | Phase to Netural 0-480V (Phase to Phase 0-830V) |
Error | ±0.05% (30V-480V) ±0.1% (5V-30V) |
Voltage measurement temperature drift | < 8 x 10 E-6/K |
Voltage measurement relative humidity drift | < 8 x 10 E-6/RH |
Voltage measurement stability | < 50 x10 E-6 |
Voltage measurement long term stability | < 80 x 10 E-6/Year |
Harmonic | 2nd-64st |
Test current | |
Range (direct connection) | 0-12A |
Error (direct connection) | ±0.05% (100mA-12A) ±0.1% (10mA-100mA) |
Range (clamp CT) | 10mA-120A |
Power & Energy measure error | ||
---|---|---|
Active power (direct connection) | ±0.05% (0.1A-12A) ±0.1% (0.01A-0.1A) |
|
Reactive power (direct connection) | ±0.1% (0.1A-12A) | |
Energy measure error | ||
Active energy (direct connection) | ±0.05% (0.1A-12A) ±0.1% (0.01A-0.1A) |
|
Reactive energy (direct connection) | ±0.1% (0.1A-12A) | |
Power/energy measurement temperature drift | < 15 x 10 E-6/K | |
Power/energy measurement relative humidity drift | < 12 x 10 E-6/RH@ 10mA-120A | |
Power/energy measurement stability | < 100 x10 E-6 | |
Power/energy measurement long term stability | < 160 x 10 E-6/Year | |
Error display | 5 digits with minimum three decimal places XX.XXX% | |
Phase angle | ||
Range | 0°-360° | |
Resolution | 0.01o | |
Error | ±0.05° | |
Frequency | ||
Range | 40-70Hz | |
Resolution | 0.001Hz | |
Error | 0.002Hz | |
Pulse input | ||
Input channel | 2 | |
Input level | 5-24V | |
Input frequency | Max. 2MHz | |
Pulse output | ||
Energy constant | 180000imp/kWh, 1800imp/kWh, 180imp/kWh | |
Pulse ratio | 1:1 | |
Output level | 5V | |
Pulse frequency | Standard 400Hz-1KHz, customized max 10KHz |
Function | ||
---|---|---|
Vector diagram | Yes | |
Waveform | Yes | |
Energy accumulation | Yes | |
Communication with PC | Yes | |
Overload protection | Yes | |
2.Cable and Accessories | ||
Test Cable | Voltage test cable 1SET Cable Length:2m (R,Y,B,Black) Current test calbe 1SET Cable Length:2m (R,Y,B,Black) |
|
Plug | Pin type 1SET (4black,2Red,2Yellow,2Green) 'U' type 1SET (4black,2Red,2Yellow,2Green) 'Ω' type 1SET (4black,2Red,2Yellow,2Green) Crocodile type 1SET (1Black,1Red,1Yellow,1Green) |
|
Accessories Bag | Yes | |
3.Mechanical parameters | ||
Instrument dimensions (W×H×D) (mm) | 245×162×60 | |
Instrument Weight (kg) | 1.8 | |
Carry case dimensions (W×H×D) (mm) | 450×320×185 | |
Carry case (kg) | 10.6 | |
4.Environmental conditions | ||
Ambient temperature | -10°C to 55°C | |
Relative humidity | 15%-95% | |
Environmental protection level | IP51 | |
5.Standard | ||
lsolation protection | IEC 61010-1:2001 | |
Energy measurement | IEC 60736 | |
Reference standard | IEC 62052-11 IEC62053-21 IEC62053-22 & IEC62053-23 IEC61010-1:2001 |
|
6.Calibration and maintenance | ||
Warranty | 5 years | |
Calibration | Lifelong free calibration service | |
Recommended calibration interval | Every two years |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
$100,000,000-$150,000,000
Employee Number:
300~350
Ecer Certification:
Active Member
Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core... Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core...
Get in touch with us
Leave a Message, we will call you back quickly!