Model No. | YF070 |
Brand | YUKA |
Origin | China |
HS Code | 8421399090 |
Clapboard | Without Clapboard |
Medium Material | Fiberglass |
Type | Cartridge Filter |
Material | Aluminum Alloy |
Housing Serve Lige | 15 Years |
Filtration Performance | From 5 μm To 0.01μm |
Maxi. Operate Pressure | 1.0mpa |
Operate Temperature | 1.5~80ºc |
Resistance Corrosion | Inside And Outside |
Parts | Dp Indicator, Auto Drain, Sight Glass |
Transport Package | Brown Inner Box & Cardboard |
Efficiency | F9 |
Element Serve Life | 2000~3000 Hours |
Filtration Grade | Medium Filter |
Connection | Rc1" |
Element Top Cap Design | Colorful To Distinguish |
Diversion Fin Design On Element Top Cap | Less Pressure Loss |
Flow Rate | 5.0 M³/Min |
Specification | Dimension: 138 X 111x 503mm |
Packaging Details | Box Package |
Delivery Time | 3-7working days |
Payment Terms | L/C,T/T |
Supply Ability | 300,000pcs/month |
Place of Origin | China |
Brand Name | Yuka |
View Detail Information
Explore similar products
1/2 Inch coalescing air filter 1.8m3/min
Compressed air filtration with 0.01 micron
Active Carbon Air Filter Cartridge Replacement
Coalescant Air Filter Precision Filter Industry Gas Filter
Product Specification
Model No. | YF070 | Brand | YUKA |
Origin | China | HS Code | 8421399090 |
Clapboard | Without Clapboard | Medium Material | Fiberglass |
Type | Cartridge Filter | Material | Aluminum Alloy |
Housing Serve Lige | 15 Years | Filtration Performance | From 5 μm To 0.01μm |
Maxi. Operate Pressure | 1.0mpa | Operate Temperature | 1.5~80ºc |
Resistance Corrosion | Inside And Outside | Parts | Dp Indicator, Auto Drain, Sight Glass |
Transport Package | Brown Inner Box & Cardboard | Efficiency | F9 |
Element Serve Life | 2000~3000 Hours | Filtration Grade | Medium Filter |
Connection | Rc1" | Element Top Cap Design | Colorful To Distinguish |
Diversion Fin Design On Element Top Cap | Less Pressure Loss | Flow Rate | 5.0 M³/Min |
Specification | Dimension: 138 X 111x 503mm | Packaging Details | Box Package |
Delivery Time | 3-7working days | Payment Terms | L/C,T/T |
Supply Ability | 300,000pcs/month | Place of Origin | China |
Brand Name | Yuka |
Coalescing Filters
Coalescing Filters are probably the most important items of purification requirements in a compressed air system,which are designed not only to filter oil vapor and water, but also to filter solid particulates to an acceptable level assmall as 0.01micron in size. Usually, in the installation system, the first filter's purpose is to pre-filter, protect the highefficiency filters from bulk contamination so as to provide high quality
compressed air. If the Air Filters worked under damp or full of water adsorption condition, it would prevent the compressed air from getting through the filter element and the air low would force the liquid to get through from the pores of the element media. thus increase working pressure drop and reduce filtration performance.
Activated Carbon Filters
Oil vapor can easily get through the coalescing filters in a state of gaseous, so the adsorptive filter must provide large activated carbon adsorption bed. Because the damp air will reduce the adsorptive ability of the activated carbon, the adsorptive filter usually installed after the adsorptive dryer, in order to guarantee effective removal of oil vapor and peculiar odor. it's not used to remove the liquid oil or aerosols, thus poor maintenance and lack of pre-filter will accelerate its invalidation.
Feature& Benefit
1. Aluminum Alloy material, 15 years serve life for filter housing under working condition from temperature 1.5ºC~80ºC.PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m3/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
YF010 | RC1/2" | 16.7 | 1.0 | 35.3 | 96 | 79 | 261 | 29 | 198 | 118 |
YF020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 261 | 29 | 198 | 118 |
YF030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 295 | 29 | 233 | 153 |
YF040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 295 | 29 | 233 | 153 |
YF060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 403 | 37 | 296 | 208 |
YF070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 503 | 37 | 396 | 303 |
YF080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 503 | 37 | 396 | 303 |
YF090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 736 | 58 | 607 | 469 |
YF100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 736 | 58 | 607 | 469 |
YF110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
YF120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
YF130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 793 | 74 | 649 | 514 |
YF140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 793 | 74 | 649 | 514 |
YF150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
YF160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
Technical requirements | Maximum operating pressure: 10 barg Operating temperature: 1.5°C~80°C. |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 |
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
10000000-50000000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
Hongrijia Depurate Facility Science & Technology Co.,Ltd. was found in China Shenzhen since 1998. YUKA is our brand, we dedicated in Compressed Air Treatment,New Delhi, South American and Middle-est has subsidiary and sales center. With 12000 square meter in Huizhou for Compressed air dryer work... Hongrijia Depurate Facility Science & Technology Co.,Ltd. was found in China Shenzhen since 1998. YUKA is our brand, we dedicated in Compressed Air Treatment,New Delhi, South American and Middle-est has subsidiary and sales center. With 12000 square meter in Huizhou for Compressed air dryer work...
Get in touch with us