China 400/5A 600/5A 800/5A resin material type class 0.5 Current Transformer
China 400/5A 600/5A 800/5A resin material type class 0.5 Current Transformer

  1. China 400/5A 600/5A 800/5A resin material type class 0.5 Current Transformer
  2. China 400/5A 600/5A 800/5A resin material type class 0.5 Current Transformer
  3. China 400/5A 600/5A 800/5A resin material type class 0.5 Current Transformer
  4. China 400/5A 600/5A 800/5A resin material type class 0.5 Current Transformer
  5. China 400/5A 600/5A 800/5A resin material type class 0.5 Current Transformer
  6. China 400/5A 600/5A 800/5A resin material type class 0.5 Current Transformer

400/5A 600/5A 800/5A resin material type class 0.5 Current Transformer

  1. MOQ: 2 Pieces
  2. Price: $2.08 - $7.50/Pieces
  3. Get Latest Price
Usage Current
Phase Single
Coil Structure TOROIDAL
Coil Number 80
Current Ratio 400/5A
Accuracy Class 0.5
Max System Voltage 720V AC
Frequency 50/60Hz
Continuous Overload 1.2 x In.
Test Voltage 3kV AC (1min)
Security Factor FS<5
Index of Casing Insulation Class B
Working Temperature -25℃ ~ +50℃
Standards IEC60044-1, VDE0414-44-1, BS3938, BS7626
Packaging Details 1. Standard Export Carton for certain inner packaging.
2. Inner Protective Foam Packaging providing Mounting Accessories.
3. Quality poly bags for each products.
Port Ningbo or Shanghai
Supply Ability 100000 Piece/Pieces per Month
Place of Origin Zhejiang, China
Brand Name YOMIN
Model Number YMLZ-0.5S

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Usage Current Phase Single
Coil Structure TOROIDAL Coil Number 80
Current Ratio 400/5A Accuracy Class 0.5
Max System Voltage 720V AC Frequency 50/60Hz
Continuous Overload 1.2 x In. Test Voltage 3kV AC (1min)
Security Factor FS<5 Index of Casing Insulation Class B
Working Temperature -25℃ ~ +50℃ Standards IEC60044-1, VDE0414-44-1, BS3938, BS7626
Packaging Details 1. Standard Export Carton for certain inner packaging.
2. Inner Protective Foam Packaging providing Mounting Accessories.
3. Quality poly bags for each products.
Port Ningbo or Shanghai
Supply Ability 100000 Piece/Pieces per Month Place of Origin Zhejiang, China
Brand Name YOMIN Model Number YMLZ-0.5S

400/5A resin type class 0.5 Current Transformer 

Model: YMLZ-0.5S

 

 

 

Product Overview

 

Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They're connected with the Panel Meter or Relay and they can help to measure the current or protect the equipments. Low voltage current transformers are manufactured as of two types for measuring CT.

 


 

 

  • Measuring CT: Measuring current transformers are constructed to feed on other low voltage apparatus such as measuring instruments, relays, watt-hour meter (KW meter) and these type of current transformers are mainly used 0.5 and 1.0 class to transfer the current from highest rated current to rated secondary current.

 

 

 

  • Protection CT: Protection current transformers are constructed to feed the protection relay. These type of current transformers are mainly used 5P.  

 

 

 

 

Selection of the Current Transformer

 

To select the current transformer correctly, the following points should be clarified:

  • -The application (for measuring or protection).
  • -The features of the working environment (Indoor or outdoor, operating temperature, air humidity etc….).
  • -Operation voltage and frequency.
  • -Range of the primary current (maximum and minimum of the current to be measured).
  • -Dimension of the cable or Bus bar.
  • -Data of the overload.
  • -Short circuit current.
  • -Specification of the measuring device associated with the current transformer (Accuracy, rated current, consumption etc…).
  • -The diameter and length of the cable, the cable which is used to connect the current transformer and associated measuring device.

 

  

 

 

 

 

 

 

 

 

 

Accuracy of A Current Transformer

 

The percentage of error, produced in a transformer, is established by IEC60044-1. In measurement transformer: 25% and 100% of nominal power. In protection transformers: 100% of nominal power.

 

Note: with…/1A transformers losses are reduced 25 times.

 

 

 

 

 

 

Saturated Condition of CT

 

The current transformer is saturated if the primary current, passing through the CT, is greater than the nominal rating of the CT.

 

The linearity of CT, between the primary and secondary sides decreases, so error increases. The saturation of the CT is inversely proportional to the load (FIG. 1).

 

The difference between measuring and protection current transformers is their behavior when an overload occurs on the primary side. Measuring CT is saturated when there is a primary current overload. In order to protect the equipment. On the secondary side, protection CT will not saturated until there is a very high current on the primary side, A class 5P15 protection transformer indicates that it has an accuracy rating of ±1% that it does not become saturated until the primary current reaches 15 times the nominal current rating of the CT.

In measuring transformers, the SAFETY FACTOR “FS” parameter indicates the excessive amperage on the primary side current in relation to the current sent to the measuring device on the secondary side.

 

 

 

 

Application Note

 

If the primary current is too small, to keep the same accuracy and output, we can add primary winding, but the rated turns ration should be the same, For example, if the primary current is 50A, we can use 100/5A current transformer with the primary current be turned twice which help to keep the same rated turns ratio (1:50 = 2:100).

 

 

 

Construction

 

 

 

CT consist of primary winding, secondary winding, magnetic core and insulated body. The high-grade silicon steel core is annealed, varnished then insulated with polycarbonate core caps. The secondary winding is toroidally wound by high precision semi-automatic machinery. For the tape wound ring type current transformer, the PEW coated windings are then covered with elephantite paper, varnished and double-tapped with PVS tapes. For the encapsulated type current transformer, the windings are enclosed in a compact and heat resistant split cap.

 

 

 

Specifications
 

 

 

 

  • Current Ratio..................................................................................400/5A
  • Accuracy.........................................................................................Class 0.5
  • Burden.............................................................................................See Selection Form.
  • Security Factor................................................................................FS<5
  • Max System Voltage.......................................................................720V AC
  • Test Voltage.....................................................................................3kV AC. (1 min.)
  • Frequency........................................................................................50/60Hz
  • Rated Short-time Thermal Current (Ith)........................................Ith = 60 X In
  • Rated Dynamic Current (Idyn).......................................................Idyn = 2.5 X Ith
  • Continuous Overload.....................................................................1.2 X In
  • Working Temperature....................................................................-25°C ~ +50°C
  • insulation Rating.............................................................................Class B
  • Housing Self-extinguishing Class.................................................VO.
  • Bus-bar Support Mounting.............................................................Provided.
  • Panel Mounting................................................................................Provided.
  • Hinged Sealable Terminal Cover....................................................No Provided.
  • Standards.........................................................................................IEC/EN60044-1, VDE0414-44-1, BS3938, BS7626
  • Item Condition..................................................................................Brand New.
  • Quality Assurance...........................................................................24 Months.
  • Sample Service................................................................................Provided.

 

 

 

 

 

Selection Form

 

ItemCurrent RatioRated Burden (VA)Case Qty.
Model(A)Class: 0.5Class: 1.0(Pcs)
DP-23200/5-1.520
250/5-2.520
300/51.52.520
400/52.53.7520

 

 

 

 

Company Information



Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Ecer Certification:

    Active Member

Yueqing Yomin Electric Co., Ltd (Before called Yueqing Yomin Electric Factory, found in 1996) is a manufacturer of electric appliances with well-equipped testing equipment and strong technical force.With a wide range, good quality, reasonable prices and stylish designs, our products are extensively ... Yueqing Yomin Electric Co., Ltd (Before called Yueqing Yomin Electric Factory, found in 1996) is a manufacturer of electric appliances with well-equipped testing equipment and strong technical force.With a wide range, good quality, reasonable prices and stylish designs, our products are extensively ...

+ Read More

Get in touch with us

  • Reach Us
  • Yueqing Yomin Electric Co., Ltd
  • https://yominsun-com.ecer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement