Usage | Potential |
Phase | Single |
Coil Structure | TOROIDAL, Toroidal |
Coil Number | AUTOTRANSFORMER, Autotransformer |
Product name | LV Current Transformer |
Max System Voltage | 720V AC |
Test Voltage | 3kv AC (1min) |
Current Ratio | 800/5A |
Frequency | 50/60Hz |
Primary Current | 5-100A |
Type | Window |
Accuracy | class 0.5 |
Packaging Details | 1.Standard export carton for certain inner packaging.
2.Inner packaging providing mounting accessories. 3.Quality poly bags for each products. |
Port | Ningbo or shanghai |
Supply Ability | 500000 Unit/Units per Month LMZ Current Transformer |
Place of Origin | Zhejiang, China |
Brand Name | YOMIN |
Model Number | LMZ |
View Detail Information
Explore similar products
TDGC2 10KVA 40 Amp Ac Variac 230V Transformer
TDGC2 5KVA Voltage Regulator Single Phase 20 Amp 220 Volt Variac Price
Manufacturer TDGC2-3 Single Phase Voltage Variac 220v Electric 5kva Variac
TDGC2 Voltage Regulator 220V Variac 0.2KVA 0.8 Amp Cheap Low Voltage Variac 200W
Product Specification
Usage | Potential | Phase | Single |
Coil Structure | TOROIDAL, Toroidal | Coil Number | AUTOTRANSFORMER, Autotransformer |
Product name | LV Current Transformer | Max System Voltage | 720V AC |
Test Voltage | 3kv AC (1min) | Current Ratio | 800/5A |
Frequency | 50/60Hz | Primary Current | 5-100A |
Type | Window | Accuracy | class 0.5 |
Packaging Details | 1.Standard export carton for certain inner packaging.
2.Inner packaging providing mounting accessories. 3.Quality poly bags for each products. |
Port | Ningbo or shanghai |
Supply Ability | 500000 Unit/Units per Month LMZ Current Transformer | Place of Origin | Zhejiang, China |
Brand Name | YOMIN | Model Number | LMZ |
Mini Ring Red Epoxy Resin Current Transformer CT 1/1a
Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They're connected with the Panel Meter or Relay and they can help to measure the current or protect the equipments. Low voltage current transformers are manufactured as of two types for measuring CT.
Selection of the Current Transformer
To select the current transformer correctly, the following points should be clarified:
Power Losses of the CT
In the practical application, the power generated by the primary current should be equal or bigger than the power requirement of the associated measuring device plus the consumption of the connecting line.
Losses in the line, PL:
This is the power loss, through heat, generated by current through the resistance RL in the cable, in the transformer’s secondary circuit.
Factors to be taken into account:
Secondary current: PL = RL / 2
Cable diameter: RL is inversely proportional to the square of the diameter cable length: RL is proportional to the length of cabling (there and back).
Power: The nominal apparent power (VA) with a specified power factor, which was supplied by the Current Transformer, to the secondary current with the assigned current when it is connected to its nominal load. Sc (VA) = Zc (/sn)2 According to Standards, for apparent power greater than or equal to 5VA, the power factor is 0.8 inductive. For apparent power less than 5VA the power factor is considered to be one (unity).
Accuracy of A Current Transformer
The percentage of error, produced in a transformer, is established by IEC60044-1. In measurement transformer: 25% and 100% of nominal power. In protection transformers: 100% of nominal power.
Note: with…/1A transformers losses are reduced 25 times.
Saturated Condition of CT
The current transformer is saturated if the primary current, passing through the CT, is greater than the nominal rating of the CT.
The linearity of CT, between the primary and secondary sides decreases, so error increases. The saturation of the CT is inversely proportional to the load (FIG. 1).
The difference between measuring and protection current transformers is their behavior when an overload occurs on the primary side. Measuring CT is saturated when there is a primary current overload. In order to protect the equipment. On the secondary side, protection CT will not saturated until there is a very high current on the primary side, A class 5P15 protection transformer indicates that it has an accuracy rating of ±1% that it does not become saturated until the primary current reaches 15 times the nominal current rating of the CT.
In measuring transformers, the SAFETY FACTOR “FS” parameter indicates the excessive amperage on the primary side current in relation to the current sent to the measuring device on the secondary side.
Application Note
If the primary current is too small, to keep the same accuracy and output, we can add primary winding, but the rated turns ration should be the same, For example, if the primary current is 50A, we can use 100/5A current transformer with the primary current be turned twice which help to keep the same rated turns ratio (1:50 = 2:100).
Construction
CT consist of primary winding, secondary winding, magnetic core and insulated body. The high-grade silicon steel core is annealed, varnished then insulated with polycarbonate core caps. The secondary winding is toroidally wound by high precision semi-automatic machinery. For the tape wound ring type current transformer, the PEW coated windings are then covered with elephantite paper, varnished and double-tapped with PVS tapes. For the encapsulated type current transformer, the windings are enclosed in a compact and heat resistant split cap.
Item | Current Ratio | Rated Burden (VA) | Case Qty. | |
Model | (A) | Class: 0.5 | Class: 1.0 | (Pcs) |
MSQ-100 | 800/5 | 5 | 5 | 16 |
MSQ-100 | 1000/5 | 10 | 10 | 16 |
MSQ-100 | 1200/5 | 10 | 15 | 16 |
MSQ-100 | 1250/5 | 10 | 15 | 16 |
MSQ-100 | 1500/5 | 10 | 15 | 16 |
MSQ-100 | 1600/5 | 10 | 15 | 16 |
MSQ-100 | 2000/5 | 10 | 15 | 16 |
MSQ-100 | 2500/5 | 10 | 15 | 16 |
MSQ-100 | 3000/5 | 10 | 15 | 16 |
Note:
Class and VA rating must be mentioned when ordering.
Thank you for viewing this listing.
Please take a moment to review our other items.
Add us to your favourite sellers list, many thanks!
1 Where is your factory?
Our factory is located in Qiaoqian Industry Area, Liushi Town, Yueqing City, Zhejiang Province, 325603 China.
2 Are you manufacturer or business?
We are manufacturer established in 2002, and have over 16 years production experience.
3. Can I ask for samples?
Yes
4. What's the warranty of your products?
18 months
5. What's the lead time?
Depend on the quantity and model of the order, normally it takes around 2-3 days, but the exact lead time should be discussed with our sales.
6. How about the MOQ, Payment term, Delivery port, and shipping date?
1)MOQ: 100 pcs/item based on existing packing.
2)T/T-30% deposit and 70% against copy of BL
3)L/C is also acceptable
4)Ningbo/Shanghai
Company Details
Ecer Certification:
Active Member
Yueqing Yomin Electric Co., Ltd (Before called Yueqing Yomin Electric Factory, found in 1996) is a manufacturer of electric appliances with well-equipped testing equipment and strong technical force.With a wide range, good quality, reasonable prices and stylish designs, our products are extensively ... Yueqing Yomin Electric Co., Ltd (Before called Yueqing Yomin Electric Factory, found in 1996) is a manufacturer of electric appliances with well-equipped testing equipment and strong technical force.With a wide range, good quality, reasonable prices and stylish designs, our products are extensively ...
Get in touch with us
Leave a Message, we will call you back quickly!