Payment Terms | T/T, Western Union |
Supply Ability | 10000PCS/Month |
Delivery Time | 3 Working days |
Packaging Details | 100pcs/carton |
Product Type | Heat Detector |
Certificaiton | EN54 |
Apaitplicon | Fire Safety System |
Wired | 2 wire |
Specification | D103mm, H55mm |
Weight | 155g |
Brand Name | XHA |
Model Number | YT105 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
2 Wire Conventional Fire Alarm System Wall Mount With Sound And Light Alarm
AC90-270V Fire Alarm Control Panel 4 Zone 8 Zone 16 Zone With Conventional Smoke
Wall / Ceiling Mount Conventional Fire Alarm System With Smoke / Heat Detector
4 Zone 8 Zone 16 Zone Conventional Fire Alarm System For Industrial Buildings
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 10000PCS/Month |
Delivery Time | 3 Working days | Packaging Details | 100pcs/carton |
Product Type | Heat Detector | Certificaiton | EN54 |
Apaitplicon | Fire Safety System | Wired | 2 wire |
Specification | D103mm, H55mm | Weight | 155g |
Brand Name | XHA | Model Number | YT105 |
Certification | CE | Place of Origin | China |
High Light | Conventional Rate Of Rise Heat Detector ROR ,Fixed Rate Of Rise Heat Detector ,Rate Of Rise And Fixed Temperature Heat Detectors |
2 Wire Fixed Rate-of-Rise Heat Detector for Conventional Fire Safety Fire Alarm System
Product Name | Conventional heat detector | Rated operational voltage | 15 to 28VDC Volts Non-polarized |
Fixed Temperature Rating: | 135°F (57°C) | Static current | ≤40µA @ 24 VDC |
Alarm current | ≤30mA @ 24 VDC | Work temperature | -10°C~+50°C |
Certification | EN54 | Humidity | ≤95%. |
Size | 103*103*55mm | Weight | 155 g |
Installation
IMPORTANT: The detector must be tested and maintained regularly following NFPA 72 requirements. The detector should be cleaned at least once a year.
INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.
Remove power from initiating-device circuits before installing detectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.
Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.
Terminals functions description:
Terminal 2: IN+( Zone Input+)
Terminal 5: IN- (Zone Input- )
Terminal 6: IN+( Zone Output+)
Terminal 5: IN- (Zone Output- )
Terminal 6: Remote Indicator+
Terminal 3: Remote Indicator
Product range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.
Company Details
Year Established:
2001
Total Annual:
4300000-7140000
Employee Number:
40~50
Ecer Certification:
Verified Supplier
We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...
Get in touch with us
Leave a Message, we will call you back quickly!