China TX7130 Reflective Optical Beam Smoke Detector LPCB Certification
China TX7130 Reflective Optical Beam Smoke Detector LPCB Certification

  1. China TX7130 Reflective Optical Beam Smoke Detector LPCB Certification
  2. China TX7130 Reflective Optical Beam Smoke Detector LPCB Certification

TX7130 Reflective Optical Beam Smoke Detector LPCB Certification

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, Western Union,
Supply Ability 1000PCS/Month
Delivery Time 7 Working days
Packaging Details 61*54*31CM
Detector Type Reflective Beam Smoke Detector
Applicaiton conventional/addressable fire alarm system
Power Supply DC24V
Path Length 5-100m
Transport Package Carton
Output Realy output: 1A DC24V
Certifications LPCB
Brand Name TANDA
Model Number TX7130
Certification LPCB
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, Supply Ability 1000PCS/Month
Delivery Time 7 Working days Packaging Details 61*54*31CM
Detector Type Reflective Beam Smoke Detector Applicaiton conventional/addressable fire alarm system
Power Supply DC24V Path Length 5-100m
Transport Package Carton Output Realy output: 1A DC24V
Certifications LPCB Brand Name TANDA
Model Number TX7130 Certification LPCB
Place of Origin China
High Light Reflective Beam Smoke DetectorOptical Beam Smoke DetectorTX7130 Beam Smoke Detector

LPCB Certification TX7130 Reflective Optical Beam Smoke Detector For High-Performance Fire Detection

 

 




Introduction


The TX7130 reflective optical beam smoke detector incorporates a light transmitter and the detector on the same unit. The light path is created by reflecting light emitted from the transmitter off a retro- reflector, meaning it is reflecting light back to its source with a minimum of scattering, which is placed opposite the detector.

In a fire, when smoke falls within the path of the beam detector, some of the light is absorbed or scattered by the smoke particles. This creates a decrease in the received signal, leading to an increase in optical obscuration. This unit decodes or analysts received signals and compare to the pre-programmed algorithm stored on the processor. Through this algorithm the detector will decide whether fire is defined or not and lead to enablement the corresponding relays and LED indicators. The unit on the operating mode maintaining continually emitting light, care should be taken that the activities in the space do not obstruct the beam or move the device to avoid false operation of the detector


 

Specifications
 

Operating Voltage 20 V to 28 V DC

Current Parameters Standby: 23mA Commission: 56mA Alarm: 33mA

Beam Sensor Sensitivity [via Encoder] Level 1: 2.6 dB High Sensitivity

   Level 2: 3.8 dB Medium Sensitivity

                                                               Level 3: 5.8 dB Low Sensitivity

Beam Pathway Length [via Encoder] Span 1: 8 to 20 meters Limited Path

Span 2: 20 to 40 meters Short Path

Span 3: 40 to 70 meters Normal Path

Span 4: 70 to 100 meters Long Path

Beam Path Angle ±0.4º Directional (This data takes the average of the left and right deflection angles.)

Alignment Guide Laser Beam Pointer

Digital Display Guide Nixie Tube

LED Indicator Guide Red: Fire ; Yellow: Fault ; Green: Alignment

Reset Time Less than 2 Second

Relay Capacity [Fire & Fault] Normally Open & Close/ 2.0 A; 30 VDC

Material / Colour ABS / White

Dimension / Weight L:190.87 x W:126.87 x H:91.96 mm / 440 gm

Weight 0.130 Kg with base

Operating Temperature -10°C to +50°C

Ingress Protection Rating IP30 [IP66 glue seal-For permanent fixing

Humidity 0 to 95% Relative Humidity, Non condensing

 

 
Product Range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.


 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Year Established:

    2001

  • Total Annual:

    4300000-7140000

  • Employee Number:

    40~50

  • Ecer Certification:

    Verified Supplier

We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Xinhe'an Technology Co., Ltd.
  • 406,Jude Building,Zhengfeng South Road,Fuyong Street,Bao'An District, Shenzhen City, Guangdong Province. China,518103
  • https://www.xhafiresafety.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement