China factories

China factory - Shenzhen Xinhe'an Technology Co., Ltd.

Shenzhen Xinhe'an Technology Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Addressable Monitor Module Wall Mounting For Intelligent Fire Alarm System
China Addressable Monitor Module Wall Mounting For Intelligent Fire Alarm System

  1. China Addressable Monitor Module Wall Mounting For Intelligent Fire Alarm System
  2. China Addressable Monitor Module Wall Mounting For Intelligent Fire Alarm System

Addressable Monitor Module Wall Mounting For Intelligent Fire Alarm System

  1. MOQ: 1PCS
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 100000PCS/Month
Delivery Time 3 Working days
Packaging Details 100pcs/carton
Types of Smoke Detectors Monitor Module
Input Voltage 17-33VDC
Wire Type Non-Polarity 2-Wired
Installation Wall mounting
Connected loop bus
Operating Temperature -10°C to 50°C
Type Addressable
Humidity Range 10% to 95% RH
Brand Name XHA
Model Number CA9007
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 100000PCS/Month
Delivery Time 3 Working days Packaging Details 100pcs/carton
Types of Smoke Detectors Monitor Module Input Voltage 17-33VDC
Wire Type Non-Polarity 2-Wired Installation Wall mounting
Connected loop bus Operating Temperature -10°C to 50°C
Type Addressable Humidity Range 10% to 95% RH
Brand Name XHA Model Number CA9007
Certification CE Place of Origin China
High Light Fire Alarm System Addressable Monitor ModuleWall Mounting Addressable Monitor Module

 



Introduction
 

A monitor module is a device used in addressable fire alarm systems to interface with and monitor the status of other connected devices or systems.

The key functions of an input module include:

 

Monitoring Inputs:
The input module is connected to various system components, such as sprinkler flow switches, tamper switches, or other auxiliary devices.
It monitors the status of these connected inputs and relays that information to the fire alarm control panel.


Reporting Status:
When the input module detects a change in the status of a connected device (e.g., a sprinkler flow switch activating), it communicates this information to the fire alarm control panel.
This allows the control panel to accurately track the status of various fire protection and life safety systems.


Addressability:
Like other addressable devices, each input module has a unique digital address recognized by the fire alarm control panel.
This enables the control panel to identify the specific location and source of any reported alarm or supervisory signals.


Supervised Monitoring:
Input modules are typically configured to monitor their connected inputs for both normal and abnormal conditions, such as open circuits or short circuits.
This supervisory monitoring helps ensure the integrity of the overall fire alarm system.


Integration with Other Systems:
Input modules can be used to interface the fire alarm system with other building systems, like HVAC controls or elevator recall, allowing for coordinated emergency response.


So in summary, the terms "input module" and "monitor module" are used interchangeably to refer to these addressable devices that provide input monitoring and status reporting capabilities within a fire alarm system.



Parameters
 
Product name Input  Module Type Addressable
Loop Bus wired 2-wire Non-polarized Monitor Current ≤350uA
Alarm Currrent ≤2mA Dimension Φ85*40 mm
Work voltage DC17V~DC33V Operating Environment Temperature -10°C~+50°C
 Humidity ≤95%.
Weight Weight:60g(with base) Certification CE


 

 

Connection between Input Module

 

 

 

 

Connection Diagram of Fire Alarm System

 

 

 

 



Product range
 

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Year Established:

    2001

  • Total Annual:

    4300000-7140000

  • Employee Number:

    40~50

  • Ecer Certification:

    Verified Supplier

We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Xinhe'an Technology Co., Ltd.
  • 406,Jude Building,Zhengfeng South Road,Fuyong Street,Bao'An District, Shenzhen City, Guangdong Province. China,518103
  • https://www.xhafiresafety.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement