China factories

China factory - Shenzhen Xinhe'an Technology Co., Ltd.

Shenzhen Xinhe'an Technology Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China High Performance Convenional 2 Wire Smoke Detector For Fire Alarm Fire Security
China High Performance Convenional 2 Wire Smoke Detector For Fire Alarm Fire Security

  1. China High Performance Convenional 2 Wire Smoke Detector For Fire Alarm Fire Security
  2. China High Performance Convenional 2 Wire Smoke Detector For Fire Alarm Fire Security

High Performance Convenional 2 Wire Smoke Detector For Fire Alarm Fire Security

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 10000PCS/Month
Delivery Time 3 Working days
Packaging Details 100pcs/carton
Product Type Conventional Fire Alarm System
Wired 2 wire.Non-polarized
Adjustable Sensitivity 1.06±.26%FT
Humidity Range 10% to 95% non-condensing
Specification D103mm, H55mm
Operating Temperature -10°C to +50°C
Brand Name XHA
Model Number YT102
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 10000PCS/Month
Delivery Time 3 Working days Packaging Details 100pcs/carton
Product Type Conventional Fire Alarm System Wired 2 wire.Non-polarized
Adjustable Sensitivity 1.06±.26%FT Humidity Range 10% to 95% non-condensing
Specification D103mm, H55mm Operating Temperature -10°C to +50°C
Brand Name XHA Model Number YT102
Certification CE Place of Origin China
High Light High Performance 2 Wire Smoke DetectorConvenional 2 Wire Smoke Detector

Introduction
 

By quickly and reliably detecting the presence of smoke and activating an alarm, conventional smoke detectors play a critical role in fire safety, providing early warning of potential fires and allowing building occupants to evacuate the premises in a timely manner.

 

The primary function of a conventional smoke detector is to detect the presence of smoke, which is an early indicator of a fire, and to activate an alarm to alert building occupants of the potential fire hazard.

Here are the key functions of a conventional smoke detector:

 

Smoke Detection:
Conventional smoke detectors use either ionization or photoelectric (optical) smoke detection technology to sense the presence of smoke particles in the air.
The detector's sensor continuously monitors the surrounding environment for changes in the concentration of smoke particles.
When the smoke density reaches a pre-determined threshold, the detector recognizes the presence of smoke.


Alarm Activation:
Upon detecting smoke, the conventional smoke detector will activate an alarm to notify building occupants of the potential fire emergency.
The alarm can take the form of an audible signal, such as a buzzer or siren, and/or a visual signal, such as a flashing light.
The alarm is designed to be loud and attention-grabbing to ensure that occupants are aware of the need to evacuate the building.

Monitoring and Reporting:
Some conventional smoke detectors may be connected to a centralized fire alarm control panel or system.
This allows the status of the smoke detector, including any alarm conditions, to be monitored and reported to a central location, such as a fire station or security office.


Self-Monitoring and Testing:
Many conventional smoke detectors incorporate self-monitoring and testing capabilities to ensure they remain in good working order.
This may include periodic self-checks of the sensor, power supply, and internal components, as well as the ability to perform manual testing by the building occupants or maintenance personnel.



Parameters

Product Name  Smoke Alarm Rated operational voltage 9 to 28VDC Volts Non-polarized
Adjustable Sensitivity 1.06±.26%FT Static current 40µA @ 24 VDC
Alarm current 30mA @ 24 VDC Work temperature -10°C~+50°C
Certification EN54 Humidity ≤95%.
Size  103*103*55mm Weight 155 g

 

 

Feature

 

Conventional Smoke Detector, Operates by Advanced MCU Expert Algorithm Software.
Key Specifications/Special Features
They work perfectly with all conventional intelligent fire control panels
Dual LEDs for 360-degree visibility
Advanced MCU Expert Algorithm Software.
Easy installation and maintenance
Durable sensor head, no need for replacement
SMD circuit board design-satisfactory quality and reliability guaranteed

 

 

Installation

 

IMPORTANT: The detector must be tested and maintained regularly following NFPA 72 requirements. The detector should be cleaned at least once a year.
INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

Remove power from initiating-device circuits before installing detectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.

      Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.

      

 


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector

 

 



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.




 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Year Established:

    2001

  • Total Annual:

    4300000-7140000

  • Employee Number:

    40~50

  • Ecer Certification:

    Verified Supplier

We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Xinhe'an Technology Co., Ltd.
  • 406,Jude Building,Zhengfeng South Road,Fuyong Street,Bao'An District, Shenzhen City, Guangdong Province. China,518103
  • https://www.xhafiresafety.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement