China factories

China factory - WUHU WANYI INDUSTRY CO.,LTD

WUHU WANYI INDUSTRY CO.,LTD

  • China,Wuhu ,Anhui
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China molbloc-L Laminar Flow Element MOLBLOC-S SONIC NOZZLE MOLBOX1+FLOW Terminal
China molbloc-L Laminar Flow Element MOLBLOC-S SONIC NOZZLE MOLBOX1+FLOW Terminal

  1. China molbloc-L Laminar Flow Element MOLBLOC-S SONIC NOZZLE MOLBOX1+FLOW Terminal

molbloc-L Laminar Flow Element MOLBLOC-S SONIC NOZZLE MOLBOX1+FLOW Terminal

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union
Supply Ability 1000pcs
Delivery Time 15-20days
Packaging Details Carton
Brand Name Fluke
Model Number molbloc-L Laminar Flow Element MOLBLOC-S SONIC NOZZLE MOLBOX1+FLOW Terminal
Certification CCCI
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union Supply Ability 1000pcs
Delivery Time 15-20days Packaging Details Carton
Brand Name Fluke Model Number molbloc-L Laminar Flow Element MOLBLOC-S SONIC NOZZLE MOLBOX1+FLOW Terminal
Certification CCCI Place of Origin China

Product overview: molbloc-L Laminar Flow Element

Features at a glance

  • Useable with existing molbox1+ and molbox RFM mass flow terminals and COMPASS software
  • Integrated filter to protect against contamination
  • Integral gas temperature conditioning and measurement
  • Continuous, real-time reading
  • Can be fully automated
  • No moving parts

molbloc-L Ranges
molblocs sizes are designated by a number relative to their nominal flow impedance. The nominal impedance results in nominal flow ranges when flowing nitrogen gas with 250 kPa absolute (36 psia) upstream pressure and 50 kPa (7.5 psid) differential pressure across the molbloc. In practice, the molbloc flow range may be quite different from the nominal flow range. The difference comes from differences in density and viscosity between gases and from different molbloc operating pressure calibration options.

Specifications: molbloc-L Laminar Flow Element

Specifications - Standard molbloc-L Calibrations - Used with molbox1+ terminal
Measurement Update Rate 1 second
Range 0 to molbloc full scale depending on gas and molbloc pressure
dependent calibration type (see Section 1.2.5.1.3)
Resolution 0.0015 % FS
Linearity ± 0.05 % of reading from 10 to 100 % FS,
± 0.005 % FS under 10 % FS
Repeatability ± 0.05 % of reading from 10 to 100 % FS,
± 0.005 % FS under 10 % FS
Precision1 ± 0.07 % of reading from 10 to 100 % FS,
± 0.007 % FS under 10 % FS
Stability2
(1 year)
± 0.09 % of reading from 10 to 100 % FS,
± 0.009 % FS under 10 % FS
Measurement Uncertainty3 ± 0.2 % of reading from 10 to 100 % FS,
± 0.02 % FS under 10 % FS
(N2 and any molbox1+ supported gas for which the molbloc in use is calibrated) 1E5 molbloc
± 0.5% of reading from 25 to 100 % FS,
± 0.125 % FS under 25 % FS
1 Precision: Combined linearity, hysteresis, repeatability.
2 Stability: Maximum change in zero and span over specified time period for typical molbox1+ and molbloc used under typical conditions. As stability can only be predicted, stability for a specific molbloc and molbox1+ should be established from experience.
3 Measurement uncertainty (accuracy): Maximum deviation of the molbox1+ flow indication from the true value of the flow through the molbloc including precision, stability and Fluke calibration standard measurement uncertainty.
Specifications - Premium molbloc-L Calibrations - Used with molbox1+ terminal
Measurement Update Rate 1 second
Range 0 to molbloc full scale depending on gas and molbloc pressure dependent calibration type (see Section 1.2.5.1.2)
Resolution 0.0015 % FS
Linearity ± 0.05 % of reading from 10 to 100 % FS,
± 0.005 % FS under 10 % FS
Repeatability ± 0.05 % of reading from 10 to 100 % FS,
± 0.005 % FS under 10 % FS
Precision1 ± 0.07 % of reading from 10 to 100 % FS,
± 0.007 % FS under 10 % FS
Stability2
(1 year)
± 0.03 % of reading from 10 to 100 % FS,
± 0.003 % FS under 10 % FS
Measurement Uncertainty3 ± 0.125 % of reading from 10 to 100 % FS,
± 0.0125 % FS under 10 % FS
(N2 and any molbox1+ supported gas for which the molbloc in use is calibrated) 1E5 molbloc-L Premium calibration not available
1 Precision: Combined linearity, hysteresis, repeatability.
2 Stability: Maximum change in zero and span over specified time period for typical molbox1+ and molbloc used under typical conditions. As stability can only be predicted, stability for a specific molbloc and molbox1+ should be established from experience.
3 Measurement uncertainty (accuracy): Maximum deviation of the molbox1+ flow indication from the true value of the flow through the molbloc including precision, stability and Fluke calibration standard measurement uncertainty.
Specifications - Standard molbloc-L Calibrations - Used with molbox RFM terminal
  molbloc-L (ranges 1E1-L thru 3E4-L)
Measurement update rate 1 second
Range 0 to molbloc full scale depending on gas and molbloc pressure dependent calibration type (see molbloc-L range sheet tables)
Resolution 0.01 % FS
Linearity ± 0.23 % of reading from 10 % to 100 % FS, ± 0.023 % FS under 10 % FS
Repeatability ± 0.1% of reading from 10 % to 100 % FS, ± 0.01% FS under 10 % FS
Precision1 ± 0.25 % of reading from 10 % to 100 % FS, ± 0.025 % FS under 10 % FS
Predicted stability2
(one year)
± 0.15 % of reading from 10 % to 100 % FS, ± 0.015 % FS under 10 % FS
Measurement uncertainty3 ± 0.5 % of reading from 10 % to 100 % FS, ± 0.05 % FS under 10 % FS
molbox RFM with Microrange option
  molbloc-L (ranges 1E1-L thru 3E4-L) molbloc-L (ranges 1E5 only)
Measurement update rate 1 second 1 second
Range 0 to molbloc full scale depending on gas and molbloc pressure dependent calibration type (see molbloc-L tables) 0 to molbloc full scale depending on gas and molbloc pressure dependent calibration type (see molbloc-L tables)
Resolution 0.01 % FS, 0.001 % FS under 0.001 % FS under 10% FS 0.01 % FS
Linearity ± 0.23 % of reading from 1 % to 100 % FS,
± 0.0023 % FS under 1 % FS
± 0.25 % of reading from 5 % to 100 % FS, ± 0.0125 % FS under 5 % FS
Repeatability ± 0.1 % of reading from 1 % to 100 % FS, ± 0.001 % FS under 1 % FS ± 0.2 % of reading from 5 % to 100 % FS, ± 0.01 % FS under 5% FS
Precision1 ± 0.25 % of reading from 1 % to 100 % FS, ± 0.0025 % FS under 1% FS ± 0.32 % of reading from 5 % to 100 % FS, ± 0.016 % FS under 5 % FS
Predicted stability2
(one year)
± 0.15 % of reading from 1 % to 100 % FS, ± 0.0015 % FS under 1 % FS ± 0.2 % of reading from 5 % to 100 % FS, ± 0.01 % FS under 5 % FS
Measurement uncertainty3 ± 0.5 % of reading from 1 % to 100 % FS, ± 0.005 % FS under 1 % FS ± 0.5 % of reading from 5 % to 100 % FS, ± 0.025 % FS under 5 % FS

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter

  • Year Established:

    2011

  • Total Annual:

    100000-1000000

  • Employee Number:

    15~50

  • Ecer Certification:

    Site Member

Our company produces and sells various stainless steel products, and supports customized production of various non-standard products. Stainless steel products are mainly used in fields such as medicine and universities.     Our company also can export kinds of stainless steel prod... Our company produces and sells various stainless steel products, and supports customized production of various non-standard products. Stainless steel products are mainly used in fields such as medicine and universities.     Our company also can export kinds of stainless steel prod...

+ Read More

Get in touch with us

  • Reach Us
  • WUHU WANYI INDUSTRY CO.,LTD
  • No7 .Baizhuangkuajie zhanghe road, Yijiang zone, Wuhu City,Anhui Province,China 241000
  • https://www.wuhuwanyi.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement