China Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit F414D/62
China Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit F414D/62

  1. China Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit F414D/62

Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit F414D/62

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union
Supply Ability 1000pcs
Delivery Time 15-20days
Packaging Details Carton
Brand Name Fluke
Model Number Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit F414D/62 MAX+
Certification CCCI
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union Supply Ability 1000pcs
Delivery Time 15-20days Packaging Details Carton
Brand Name Fluke Model Number Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit F414D/62 MAX+
Certification CCCI Place of Origin China

Product overview: Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

The most rugged Fluke 62 MAX+ IR thermometer teamed with the easy to use 414D Laser Distance Meter has everything you need to configure layout and to troubleshoot electrical/hvac problems quickly. Use the IR thermometer to test for overheating in electrical devices and HVAC components, and use the laser distance meter to determine distance, area, and volume for space configuration.

Specifications: Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

Fluke 414D Laser Distance Meter

Distance Measurement
Typical Measuring Tolerance ¹ ±2.0 mm ³
Maximum Measuring Tolerance ² ±3.0 mm ³
Range At Leica Target Plate GZM26 50 m / 165 ft
Typical Range ¹ 40 m / 130 ft
Range At Unfavorable Condition 4 35 m / 115 ft
Smallest Unit Displayed 1 mm / 1/16 in
Ø Laser Point At Distances 6 / 30 / 60 mm
(10 / 50 / 100 m)
Tilt Measurement
Measuring Tolerance To Laser Beam 5 No
Measuring Tolerance To Housing 5 No
Range No
General
Laser Class 2
Laser Type 635 nm, < 1 mW
Protection Class IP40
Automatic Laser Off After 90 seconds
Automatic Power Off After 180 seconds
Battery Life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000 measurements
Size (L x W x D) 116 x 53 x 33 mm
Weight (with batteries) 113 g
Temperature Range:
Storage Operation
-25 °C to +70 °C (-13 °F to +158 °F)
0 °C to +40 °C (32 °F to +104 °F)
Calibration Cycle Not applicable
Maximum Altitude 3000 m
Maximum Relative Humidity 85% at 20 °F to 120 °F (-7 °C to 50 °C)
Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25 °C.
2. Applies for 10 to 500% target reflectivity, high background illumination, -10 °C to +50 °C.
3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.
5. After user calibration. Additional angle related deviation of ±0.01 ° per degree up to ±45 ° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1 °

Fluke 62 MAX+ Infrared Thermometer

Specifications
Temperature Range -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62 MAX+ < 300 ms (95% of reading)
Spectral response 8 to 14 microns
Emissivity 0.10 to 1.00
Optical Resolution 12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability Of Readings ±0.5% of reading or < ±0.5 °C (1 °F), whichever is greater
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications
Weight 255 g (8.99 oz)
Size (L x W x D) 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature (Without Battery) -20 °C to 60 °C (-4 °F to 140 °F)
Operating Humidity 10% to 90% RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration And Shock IEC 68-2-6 2.5 g, 10 to 200 Hz
IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006
EN 61326-2:2006
Standards And Agency Approval
Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter

  • Year Established:

    2011

  • Total Annual:

    100000-1000000

  • Employee Number:

    15~50

  • Ecer Certification:

    Site Member

Our company produces and sells various stainless steel products, and supports customized production of various non-standard products. Stainless steel products are mainly used in fields such as medicine and universities.     Our company also can export kinds of stainless steel prod... Our company produces and sells various stainless steel products, and supports customized production of various non-standard products. Stainless steel products are mainly used in fields such as medicine and universities.     Our company also can export kinds of stainless steel prod...

+ Read More

Get in touch with us

  • Reach Us
  • WUHU WANYI INDUSTRY CO.,LTD
  • No7 .Baizhuangkuajie zhanghe road, Yijiang zone, Wuhu City,Anhui Province,China 241000
  • https://www.wuhuwanyi.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement