Payment Terms | T/T, Western Union |
Supply Ability | 6000pcs/month |
Delivery Time | 2-7 days |
Packaging Details | standard carton |
Frequency | 433/868/915MHz |
Power output | 1W |
Distance | 203km LOS |
Input | 8 digital inputs |
Output | 8 relay outputs |
Protocol | Modbus RTU |
Brand Name | Lensen |
Model Number | LS-RDIO0808 |
Place of Origin | China |
View Detail Information
Explore similar products
433MHz Wireless Tank Level Monitoring System HMI wireless control pump ON OFF
2km Modbus RTU Module I O Wireless ON OFF Control One Master To 8 Slaves
Pump ON-OFF Control System According the Float Switch High Or Low Level
2DI2DO PLC Wireless Pump Control / Relay / Valve 433MHz Wireless ON OFF Control
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 6000pcs/month |
Delivery Time | 2-7 days | Packaging Details | standard carton |
Frequency | 433/868/915MHz | Power output | 1W |
Distance | 203km LOS | Input | 8 digital inputs |
Output | 8 relay outputs | Protocol | Modbus RTU |
Brand Name | Lensen | Model Number | LS-RDIO0808 |
Place of Origin | China | ||
High Light | modbus rtu module ,pump on off control |
8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure
1. LS-RDIO series module general introduction
LS-RDIO Modbus RTU is an industrial controller designed by Lensen Technology. It supports point to point, point to multi-points wireless DI, DO, AI, AO collection and control. This transceiver has the advantage of easy installation, no program required, no communication fee. It is reliable and cost-effective substitution for rail signal cable, slip ring signal wire.
This series we have 2DI/2DO module, 4DI/4DO module, 8DI/8DO module. Power output we have 2 versions, one is 100mW for 600m LOS control distance, and another one is 1W for 3km LOS control distance.
2. Application Field
LS-RDIO series I/O module is widely used in industry automation like factory central data process, pump control, oil monitoring, mining machinery, environment monitoring equipments, lifting devices, robots control, filling machine, mixing equipments, logistic line, AGV etc.
3. Parameter
Parameter | |
Power output: | 1W or 100mW version |
Power supply: | 9V-30V (usually choose 24V DC or 12V DC) |
Control distance: | 3km or (1km version) |
Baud rate: | 1200bps |
Receiving sensibility: | -123dBm@1200bps, -118dbm(9600bps) |
Networking | |
Networking: | Point to point and point to multipoint |
Port Description | |
Input: | 8 active DI (passive customized) |
Output: | 8 relay passive outputs, |
Communication port | RS485 (wireless RS485 customize) |
Current | |
Transmit current: | <600mA (or 100mA version) |
Receiving current: | <50mA (or 20mA version) |
General | |
Frequency: | 433MHz, 400, 450, 470 or other band |
Channel No: | 16 channels,can change via DIP switch |
Physical Properties | |
Dimension: | 145×90×40(mm) |
Antenna Connector: | SMA,vehicle antenna with 1.5m cable |
Temperature: | -35℃~+75℃( industrial) |
Mounting method: | Standard 3.5 inch industrial guild rail |
4. How to use wireless I/O
5. Application diagram examples
1) Point to point control
Remarks:
Module A | Module B | Input and Output Correspondence |
A(DI1-DI8) | B(DO1-DO8) | DI1-DI8 of A to control DO1-DO8 of B respectively |
A(DO1-DO8) | B(DI1-DI8) | DO1-DO8 of A is controlled by DI1-DI8 of B respectively |
Notes: A and B should use the same channel |
2) One master to control 2 slaves
Remarks:
Master Module | Slave Module | Input and Output Correspondence |
A(DI1-DI4) | B1(DO1-DO4) | DI1-DI4 of A control DO1-DO4 of B1 respectively |
A(DI5-DI8) | B2(DO1-DO4) | DI5-DI8 of A control DO1-DO4 of B2 respectively |
A(DO1-DO4) | B1(DI1-DI4) | DO1-DO4 of A is controlled by DI1-DI4 of B1 |
A(DO5-DO8) | B2(DI1-DI4) | DO5-DO8 of A is controlled by DI1-DI4 of B2 |
Notes: A and B should use the same channel |
3) One master to control 4 slaves
Remarks:
Master | Slave | Input and Output Correspondence |
A(DI1-DI2) | B1(DO1-DO2) | DI1-DI2 of A control DO1-DO2 of B1 |
A(DI3-DI4) | B2(DO1-DO2) | DI3-DI4 of A control DO1-DO2 of B2 |
A(DI5-DI6) | B3(DO1-DO2) | DI5-DI6 of A control DO1-DO2 of B3 |
A(DI7-DI8) | B4(DO1-DO2) | DI7-DI8 of A control DO1-DO2 of B4 |
A(DO1-DO2) | B1(DI1-DI2) | DO1-DO2 of A controlled by DI1-DI2 of B |
A(DO3-DO4) | B2(DI1-DI2) | DO3-DO4 of A controlled by DI1-DI2 of B2 |
A(DO5-DO6) | B3(DI1-DI2) | DO5-DO6 of A controlled by DI1-DI2 of B3 |
A(DO7-DO8) | B4(DI1-DI2) | DO7-DO8 of A controlled by DI1-DI2 of B4 |
Notes: A and B should use the same channel |
4) One master to 8 salves
Remarks:
Master | Salve | Input and control correspondence |
A(DI1) | B1(DO1) | DI1 of A control DO1 of B1 |
A(DI2) | B2(DO1) | DI2 of A control DO1 of B2 |
A(DI3) | B3(DO1) | DI3 of A control DO1 of B3 |
A(DI4) | B4(DO1) | DI4of A control DO1 of B4 |
A(DI5) | B5(DO1) | DI5 of A control DO1 of B5 |
A(DI6) | B6(DO1) | DI6 of A control DO1 of B6 |
A(DI7) | B7(DO1) | DI7 of A control DO1 of B7 |
A(DI8) | B8(DO1) | DI8 of A control DO1 of B8 |
A(DO1) | B1(DI1) | DO1 of A is controlled by DI1 of B1 |
A(DO8) | B8(DI1) | DO8 of A is controlled by DI1 of B8 |
Note: module A and B should use the same channel; |
5) To communicate with PC/PLC
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Seller
Year Established:
2014
Total Annual:
1000000-10000000
Employee Number:
100~120
Ecer Certification:
Verified Supplier
Shenzhen Qianhai Lensen Technology Co., Ltd mainly designs and produces industrial wireless data communication products including RF module, radio modem, DI, DO, AI, AO module and kinds of RF based remote control, telemetry systems and IOT products. Our products are widely used in oil, gas, wat... Shenzhen Qianhai Lensen Technology Co., Ltd mainly designs and produces industrial wireless data communication products including RF module, radio modem, DI, DO, AI, AO module and kinds of RF based remote control, telemetry systems and IOT products. Our products are widely used in oil, gas, wat...
Get in touch with us
Leave a Message, we will call you back quickly!