Payment Terms | T/T |
Supply Ability | 2000 per day (based on the number of the order) |
Delivery Time | 30 days |
Packaging Details | Carton Packaging |
Color | Grey |
Measuring Range | 10V~700V |
Power Consumption | < 0.05VA |
Accuracy | RMS 0.2 % |
Resolution | 0.01V |
Working Voltage | 220V |
Working Current | 5(60)A |
Communication Interface No. | 1 |
Brand Name | Willfar Information Techonology Co., Ltd. |
Model Number | DDS3102-P2 |
Certification | CPA/CMC/CE |
Place of Origin | Changsha, Hunan |
View Detail Information
Explore similar products
Grey Energy Efficiency Management High Performance Easy Installation DDS3102-3N
Multiple Interface Energy Efficiency Management Power Distribution Monitor
Grey Energy Efficiency Management High Performance Easy Installation DDS3102-3N
Multiple Interface Energy Efficiency Management Power Distribution Monitor
Product Specification
Payment Terms | T/T | Supply Ability | 2000 per day (based on the number of the order) |
Delivery Time | 30 days | Packaging Details | Carton Packaging |
Color | Grey | Measuring Range | 10V~700V |
Power Consumption | < 0.05VA | Accuracy | RMS 0.2 % |
Resolution | 0.01V | Working Voltage | 220V |
Working Current | 5(60)A | Communication Interface No. | 1 |
Brand Name | Willfar Information Techonology Co., Ltd. | Model Number | DDS3102-P2 |
Certification | CPA/CMC/CE | Place of Origin | Changsha, Hunan |
High Light | power monitoring device ,smart energy monitor |
Single-phase Energy Efficiency Management Monitor Device DDS3102-P2
Company Profile
Willfar Information Technology Co., Ltd.
- Established in 2004;
- Listed on the STAR Market of the Shanghai Stock Exchange in December 2019;
- Leading supplier of meter reading (AMI) equipment and operation service;
- The first company to develop "One DCU Reading Multi-meter" solution in China;
- The first company to have large-scale application of technologies and systems like "CPU smart-card Charge and Control", "One DCU Reading Multi-meter", LoRa-based RF Communication and "District Metering Area (DMA)”
Technical Parameters
Item | Parameters | |
Wiring Mode | Three Phase 3 wires, Three Phase 4 wires, Single Phase | |
Measurement |
Voltage | Reference Voltage: Un:AC380V,AC220V,AC100V,AC57.7V |
Range: 10V~700V | ||
Power Consumption: < 0.05VA(Single Phase) | ||
Accuracy: RMS 0.2 % | ||
Resolution: 0.01V | ||
Current | Nominal Current In: 0.3A,1A,1.5A,5A | |
Range: 0.001In ~ 10A | ||
Power Consumption: < 0.05VA (single line nominal current) | ||
Accuracy: RMS 0.2 % | ||
Resolution: 0.001A | ||
Power (active/reactive/apparent) |
Accuracy: 0.5%或0.2% | |
Resolution: 0.001kW/kVar/kVA | ||
Line Frequency | Range: 45 Hz~65 Hz | |
Accuracy: 0.2% | ||
Resolution: 0.01 Hz | ||
Harmonic Wave | Time: 2~50 times | |
Accuracy: Class A | ||
Resolution: 0.01 % | ||
Metering | Active Electrical Energy | Level of Accuracy: 0.5S/0.2S |
Resolution: 0.01 kWh | ||
Reactive Electrical Energy | Level of Accuracy: Class II | |
Resolution: 0.01 kvarh | ||
Digital Signal | Power Pulse Output | 2-line electric energy (active/reactive) Pulse Output |
Opto-isolator,4000VRMS | ||
Switch Output (Optional) |
2-line electromagnetic relay output | |
Normally Open Type | ||
Contact Rating: AC 250V /3A;DC 30V /3A | ||
Switch Intput (Optional) |
4-line dry contact input | |
Opto-isolator,4000VRMS | ||
Analog Signal | Transducing (analog) Output (Optional) |
4-line transducing output |
Current Output Type (4~20mA/0~20mA/0~24mA) | ||
Voltage Output Type (0~5V/0~10V) | ||
Accuracy: 0.5% | ||
Communication | RS-485 Communication Interface (Optional) |
Interface: 2-wire half duplex |
Communication Rate: 600bps~38400bps | ||
Protocol: Modbus-RTU, DL/T645 | ||
Environment | Working Temperature | -25℃~+60℃ |
Limit Working Temperature | -35℃~+70℃ | |
Relative Humidity | ≤ 95% (non-condensing) | |
Other | Power Supply | Power Supply |
Maximum Input Range: 40V~420V | ||
Power Consumption: ≤1W,2VA | ||
Dimension | Boundary Dimension (mm):96×96×95 | |
Hole size (mm):92×92 | ||
Weight | around 450g |
Feature
- High precision: comprehensively measure power parameters, active power accuracy is level 0.5s or level 1, reactive power accuracy is level 2.
- High intelligence: double rate electric energy, monitor peak or valley point rate electric energy.
- Easy reading: large screen, high brightness liquid crystal display.
- Easy installation: 35mm standardized rail type installation. Sample voltage power supply, no need for a separate auxiliary power supply.
- Multi-communication: 1-way 485 communication interface, 1-way far-IR communication, supporting MODBUS-RTU and DL/T645-2007 protocols.
- High performance: dustproof and waterproof, nationally standardized double insulation, level 4 EMC anti-disturbance test, Class B level RF electromagnetic field interference.
Certificate
CPA/CMC/CE
Situation
Suitable for electrical transforming and distribution automatic systems, industrial control and industrial automation systems, energy management systems and community power monitoring occasions etc.
Company Details
Business Type:
Manufacturer,Exporter,Seller,Other
Year Established:
2004
Total Annual:
170-180 million
Employee Number:
700~705
Ecer Certification:
Active Member
Introduction As the first company in Hunan Province to be listed on SSE STAR Market, Willfar is the pioneer manufacturer in China that can simultaneously provide related industries with all kinds of advanced electricity, water, gas and heat metering products and meters for power distribution... Introduction As the first company in Hunan Province to be listed on SSE STAR Market, Willfar is the pioneer manufacturer in China that can simultaneously provide related industries with all kinds of advanced electricity, water, gas and heat metering products and meters for power distribution...
Get in touch with us
Leave a Message, we will call you back quickly!