Product Name | Closed Cooling Tower |
Casing Material | special Mg-Al-Zn alloy coated steel or stainless steel |
Capacity | 6 to 305 nominal tons |
Feature | high efficiency |
Application | induction furnace cooling/casting cooling |
Type | induced draft fan |
Model Number | GTM Series |
Place of Origin | Jiangsu, China |
View Detail Information
Explore similar products
CCCT Crossflow Closed Cooling Tower Induced Draft Crossflow
30 To 366 Nominal Tons Induced Draft Crossflow Closed Loop Cooling Tower
High Efficiency Induced Draft Counter Flow Closed System Cooling Tower
Product Specification
Product Name | Closed Cooling Tower | Casing Material | special Mg-Al-Zn alloy coated steel or stainless steel |
Capacity | 6 to 305 nominal tons | Feature | high efficiency |
Application | induction furnace cooling/casting cooling | Type | induced draft fan |
Model Number | GTM Series | Place of Origin | Jiangsu, China |
High Light | 6 Tons Closed Circuit Cooling Tower ,Induced Draft Closed Circuit Cooling Tower ,305 ton closed loop cooling tower |
6 To 305 Nominal Tons Induced Draft Counter Flow Cooling Tower Closed Circuit Cooling Tower
Product Description:
GTM Series are of regular capacities from 6 to 305 nominal tons. Casing made in special Mg-Al-Zn alloy coated steel or stainless steel, Heat exchange coils made in stainless steel or red copper.
GTM Towers tend to be more compact, taking less installation space, working without any wet deck fill, more suitable to cool hot fluid of higher inlet temperature. The towers dimensions can be customized to suit standard containers orparticular project conditions.
Product Specification:
Model No |
Nominal Flow Rate (Ton) |
Fan |
Circulating Pump |
Connectig Pipe (mm) |
Overall Dimensions (mm) |
Weight |
|||||||||||||
Power (kw) |
Air volumn (m3/s) |
Power (kw) |
Air volumn (m3/h) |
inlet/outlet |
make up |
drainage |
L |
W |
H |
NET (kg) |
Running (kg) |
||||||||
GTM-15 |
6 |
0.55 |
2.4 |
0.75 |
20 |
DN50 |
DN25 |
DN40 |
2200 |
1000 |
1830 |
450 |
700 |
||||||
GTM-110 |
12 |
0.55 |
2.4 |
0.75 |
20 |
DN50 |
DN25 |
DN40 |
2400 |
1000 |
1900 |
490 |
800 |
||||||
GTM-115 |
18 |
0.55×2 |
2.4×2 |
0.75 |
20 |
DN65 |
DN25 |
DN40 |
2300 |
1020 |
1830 |
460 |
1000 |
||||||
GTM-120 |
24 |
0.55×2 |
2.4×2 |
0.75 |
20 |
DN65 |
DN25 |
DN40 |
2300 |
1020 |
1900 |
500 |
1050 |
||||||
GTM-225 |
30 |
0.55×2 |
2.4×2 |
1.5 |
45 |
DN80 |
DN25 |
DN40 |
2860 |
1240 |
2050 |
730 |
1650 |
||||||
GTM-230 |
37 |
1.1×2 |
3.7×2 |
1.5 |
45 |
DN80 |
DN25 |
DN40 |
2860 |
1240 |
2180 |
830 |
1760 |
||||||
GTM-235 |
43 |
1.1×2 |
3.7×2 |
1.5 |
45 |
DN65×2 |
DN25 |
DN40 |
2860 |
1240 |
2420 |
1050 |
2030 |
||||||
GTM-340 |
49 |
1.5×2 |
5.1×2 |
2.2 |
60 |
DN65×2 |
DN25 |
DN40 |
2860 |
1520 |
2440 |
1280 |
2500 |
||||||
GTM-350 |
61 |
1.5×2 |
5.1×2 |
2.2 |
60 |
DN80×2 |
DN25 |
DN40 |
2860 |
1520 |
2630 |
1370 |
2660 |
||||||
GTM-365 |
79 |
1.1×4 |
3.7×4 |
2.2 |
60 |
DN80×2 |
DN25 |
DN40 |
3200 |
1760 |
2630 |
1820 |
3460 |
||||||
GTM-370 |
85 |
1.1×4 |
3.7×4 |
2.2 |
114 |
DN80×2 |
DN25 |
DN40 |
3200 |
2120 |
2750 |
1930 |
3970 |
||||||
GTM-380 |
98 |
1.5×4 |
5.1×4 |
2.2 |
114 |
DN80×2 |
DN25 |
DN40 |
3200 |
2120 |
2750 |
2050 |
4000 |
||||||
GTM-390 |
110 |
1.5×4 |
5.1×4 |
2.2 |
114 |
DN80×2 |
DN25 |
DN40 |
3200 |
2120 |
2750 |
2150 |
4050 |
||||||
GTM-3100 |
122 |
1.5×4 |
5.1×4 |
2.2 |
114 |
DN80×2 |
DN25 |
DN40 |
3550 |
2120 |
2750 |
2330 |
4710 |
||||||
GTM-3110 |
134 |
1.5×6 |
5.1×6 |
2.2 |
114 |
DN80×2 |
DN25 |
DN40 |
4150 |
2120 |
2870 |
2650 |
5550 |
||||||
GTM-5125 |
152 |
1.5×8 |
5.1×8 |
3.7 |
140 |
DN100×2 |
DN40 |
DN40 |
4750 |
2120 |
2970 |
3100 |
6500 |
||||||
GTM-5150 |
183 |
1.5×8 |
5.1×8 |
3.7 |
140 |
DN100×2 |
DN40 |
DN40 |
5050 |
2120 |
3120 |
3500 |
7480 |
||||||
GTM-7175 |
213 |
1.5×8 |
5.1×8 |
5.5 |
160 |
DN125×2 |
DN40 |
DN40 |
5480 |
2120 |
3120 |
3800 |
8240 |
||||||
GTM-7200 |
244 |
1.5×8 |
5.1×8 |
5.5 |
160 |
DN125×2 |
DN40 |
DN40 |
5080 |
2620 |
3120 |
4800 |
9170 |
||||||
GTM-7225 |
274 |
1.5×8 |
5.1×8 |
5.5 |
160 |
DN125×2 |
DN40 |
DN40 |
5480 |
2620 |
3220 |
5600 |
11300 |
||||||
GTM-10250 |
305 |
1.5×10 |
5.1×10 |
7.5 |
240 |
DN150×2 |
DN40 |
DN40 |
6230 |
2620 |
3220 |
6000 |
12560 |
Product Workng Theory:
As counter flow towers,the dry cool air is inlet through louvers on both sides of the tower from the bottom,and drawn upwards passing a large heat exchange surface of the coils section under the induced fans,against the spraying water in the opposite way,becoming hot wet air,induced draught out of the tower into the atmosphere by the fans on the top.During this process,a part of the heat from the fluids inside the closed loop is transferred effientiy,and removed to the outside environment.
Company Details
Business Type:
Exporter,Trading Company,Seller
Year Established:
2015
Total Annual:
1000000-1200000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
Wuxi Weishi Industrial Complete Equipment Co., Ltd. was established in May 2015. The company is mainly engaged in environmental protection EPC general contracting (bulk material transportation/flue gas treatment/water treatment) and heavy industrial equipment trading have formed the "two wings ... Wuxi Weishi Industrial Complete Equipment Co., Ltd. was established in May 2015. The company is mainly engaged in environmental protection EPC general contracting (bulk material transportation/flue gas treatment/water treatment) and heavy industrial equipment trading have formed the "two wings ...
Get in touch with us
Leave a Message, we will call you back quickly!