Payment Terms | T/T, Western Union |
Supply Ability | 1000pcs/month |
Delivery Time | 3-10 working days |
Packaging Details | 1pcs/box |
Installation | Panel Mounted |
power | DC24V |
DI | 3 |
AO | 4-20Ma |
Loadcell connect | 8 Loadcells |
Brand Name | Supmeter |
Model Number | BST100-E21 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Dustproof Running Belt Weight Feeder Controller With Span Calibration
Weigh Belt Feeder Feeding Flow Indicator Controller AC220v CE Certified, Weigh
Digital Weighing Meter Belt Scale Controller BST100- D52 Belt Weighing Machine
Weighfeeder Scale Digital Weighing Instrument Indicator With Signal Junction Box
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 1000pcs/month |
Delivery Time | 3-10 working days | Packaging Details | 1pcs/box |
Installation | Panel Mounted | power | DC24V |
DI | 3 | AO | 4-20Ma |
Loadcell connect | 8 Loadcells | Brand Name | Supmeter |
Model Number | BST100-E21 | Certification | CE |
Place of Origin | China | ||
High Light | belt weigher indicator ,digital indicator with remote display |
DC24V High Accuracy Of flow control Loadcell Belt Scale Weighing Indicator With 3 DI and 4 DO
Main Features:
1 ‘Flow Set’ Analog Input [AI]: 4~20mA, 0.05%FS.
2. COM1: Optional RS232/RS485/RS422/Profibus-DP/Ethernet.
3. COM2: RS232.
4. Connect Host IPC, Remote Display, Printer&Wireless Module.
5. Outline Size [W×H×D]: 164 × 86 × 193 mm.
6. Panel Cut-out Size [W×H]: 153 × 77 mm.
7. Accuracy of Flow Control: 0.5%~1.0%.
Main Menu | Second Menu | Description |
F1 Setting | 1 Scale[Basic] | Basic scale parameters setting. |
1+Scale[Extra] | Extra scale parameters setting. | |
2 Control[Basic] | Basic feeding control parameters setting. | |
2+Control[Extra] | Extra feeding and batching control parameters setting. | |
3 Flow | Flow parameters setting. | |
4 Speed | Speed parameters setting. | |
5 Load | Load parameters setting. | |
6 Save/Print | Weight record parameters setting. | |
7 Comm. Port | Communication port parameters setting. | |
8 I/O | Input&output parameters setting. | |
9 Display | Display and operation interface parameters setting. | |
10 Date/Time | Date/Time parameters setting. | |
F2 Calibration | 1 Zero Cal. | Zero Calibration without loading for correcting Zero Value. |
2 Span Cal. Dyn. | Dynamic Span Calibration with loading measured materials or Poise Weights for correcting Span Coefficient. | |
3 Span Cal.Stat1 | Static Span Calibration with a measured chain weight as a continuous and steady load on the running belt weigher for correcting Span Coefficient. | |
4 Span Cal.Stat2 | Static Span Calibration with a measured Hanging Weight as a steady load on the running belt weigher for correcting Span Coefficient. | |
5 Span Cor. Seg. | Segmenting Span Correction. After doing Dynamic or Static Span Calibration, further corrections for 3 [AD Value: 0~60000] linear segments are optional for correcting Correction Coefficient 1~3. | |
6 Speed Cal. | Speed Coefficient Calibration. Keep the belt weigher running at a constant speed. After the running time of a revolution being measured with using a stopwatch, do this operation for correcting Speed Coefficient. | |
7 Length Cal. | Belt Length Calibration. Keep the belt weigher running at a constant speed. After the running time of a revolution being measured with using a stopwatch, do this operation for correcting Belt Length. |
Main Menu | Second Menu | Description |
F3 Weight Record | Query and print Weight Records. | |
F4 Data Clearing | 1 Clear Screen | Clear Totalized Weight and Totalized Weight Pulse Count. But Totalized Weight of Current Shift will not be cleared, so this operation has no effect on recording of weight per shift. |
2 Clear Weight | Clear Totalized Weight, Totalized Weight Pulse Count and Totalized Weight of Current Shift. The cleared value of Totalized Weight of Current Shift will not be recorded. | |
3 Clear Records | Clear History Records of Totalized Weight. But Current Totalized Weight, Totalized Weight Pulse Count and Totalized Weight of Current Shift will not be cleared. | |
F5 Security | 1 Auto-locking | If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 Calibration’ & ‘F6 Factory Adj.’, the controller will lock the keypad and return to ‘Main Display Interface’ automatically. |
2 Key-locking | Locking keypad. | |
3 Key-unlocking | Unlocking keypad. | |
4 Password Set | Exfactory Password: 000001. | |
5 RAM Reset | Restore to factory defaults. | |
F6 Factory Adj. | Special for manufacturer. | |
F7 Product Info. | Only for query. | |
1 Version No. | Version No. | |
2 Serial No. | Serial No. | |
3 Exfactory Date | Exfactory Date. | |
4 Audit Counter | Audit Trail Counter [0~99999999] for Scale parameter’s modification. | |
5 Auth. Code | Authorization Code. |
Delivery
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2005
Ecer Certification:
Site Member
Changsha SUPMETER Technological Co., Ltd., as a council member of China Weighing Instrument Association (CWIA), is a high-tech enterprise which specializes in designing and manufacturing weighing/batching controller, force measuring controller, explosion-proof controller and related system software.... Changsha SUPMETER Technological Co., Ltd., as a council member of China Weighing Instrument Association (CWIA), is a high-tech enterprise which specializes in designing and manufacturing weighing/batching controller, force measuring controller, explosion-proof controller and related system software....
Get in touch with us
Leave a Message, we will call you back quickly!