Payment Terms | L/C, T/T |
Supply Ability | 30 Pieces Per Month |
Delivery Time | 30 days |
Packaging Details | Wooden Case |
Product Name | Binary pump HPLC Chromatography Instrument |
Power consumption | 220V,50HZ |
Environment Temperature | 4 ℃ ~ 85 ℃ |
Temperature stability | ≤±0.02 ℃ |
Sampling Volume | 0.1-20.0μL |
Sample Position | 120 |
Brand Name | Wayeal |
Model Number | LC3200 |
Certification | ISO, CE |
Place of Origin | Anhui, China |
View Detail Information
Explore similar products
Wayeal Hplc High Performance Liquid Chromatography Instrument for Laboratory
OEM Hplc Liquid Chromatography Machine 150MPa For Medicine Analysis
High Efficiency HPLC Liquid Chromatography Machine In Pharmaceutical 220V 50Hz
ELSD HPLC Lab Equipment Ultra High Performance Liquid Chromatography System
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 30 Pieces Per Month |
Delivery Time | 30 days | Packaging Details | Wooden Case |
Product Name | Binary pump HPLC Chromatography Instrument | Power consumption | 220V,50HZ |
Environment Temperature | 4 ℃ ~ 85 ℃ | Temperature stability | ≤±0.02 ℃ |
Sampling Volume | 0.1-20.0μL | Sample Position | 120 |
Brand Name | Wayeal | Model Number | LC3200 |
Certification | ISO, CE | Place of Origin | Anhui, China |
High Light | DAD Detector HPLC Liquid Chromatography ,Binary Pump HPLC Liquid Chromatography ,Binary Pump HPLC Chromatography |
Binary Pump HPLC High Performance Liquid Chromatography With UV ELSD DAD Detetcor
Description of High Performance Liquid Chromatography Instrument
The high performance liquid chromatography is used to analyze less-volatile and thermal-unstable organic compounds with high boiling point and large molecular weight. It consists of reservoir, pump, sample injector, chromatographic column, detector and recorder.
Techncial Data of High Performance Liquid Chroamtogaphy Instrument
Brand: | Wayeal |
Product Name: | Liquid Chromatography Instrument |
Working Power Supply | 220V, 50Hz |
Ambient Temperature | 10~40°C |
Relative Humidity | 20~85% |
Qualitative Repeatability | ≤0.2% |
Quantitative Repeatability | ≤0.4% |
High Pressure Constant Flow Pump | |
Flow Rate Range | 0.001~10.000mL/min |
Setting Step | 0.001mL/min |
Pressure Range | 0~42MPa |
Pressure Pulsation | 0.1MPa |
Flow Rate Set Error | ±0.2% |
Flow Rate Stability | RSD≤0.06% |
Gradient Error | ±1% |
Column Oven | |
Temperature Control Range | 4~85°C |
Temperature Stability | ±0.02°C |
Temperature Setting Resolution | 0.1°C |
Autosampler | |
Injection Volume Repeatability | <0.5%RSD |
Linearity | >0.9999 |
Cross Contamination | <0.002% |
Injection Volume Accuracy Error | ±1% |
Sample Positions | 120 |
Injection Volume | 1~100μL |
UV Detector | |
Baseline Noise | ≤2.0*10-6Au |
Baseline Drift | ≤1*10-5Au/h |
Mini Detection Concentration | ≤3.0*10-9g/mL (naphthalene/methanol) |
Spectral Range | 188~900nm |
Wavelength Error | ≤±0.1nm |
Wavelength Repeatability | ≤±0.1nm |
Linearity Range | ≥103 |
DA Detector | |
Baseline Noise | ≤4*10-5Au |
Baseline Drift | ≤3*10-5Au/h |
Mini Detection Concentration | ≤2*10-8g/mL |
Spectral Range | 190~800nm |
Wavelength Error | ≤±0.1nm |
Wavelength Repeatability | ≤±0.1nm |
Linearity Range | ≥ 104 |
ELS Detector | |
Baseline Noise | ≤ 0.0037mV |
Baseline Drift | ≤ 0.0026mV/30min |
Evaporation Gas Flow Range | (0 ~ 3) SLM |
Atomization Temperature Range | Room temperature ~ 90℃ |
Evaporation Temperature Range | Room temperature~110℃ |
Detection Chamber Temperature Range | Room temperature~60℃ |
Input Air Pressure | (4 ~ 7) bar |
FL Detector | |
Baseline Noise | ≤ 5×10-6 FU |
Baseline Drift | ≤ 2 × 10-5 FU/30min |
Spectral Range | (200 ~ 650) nm |
Wavelength Error | ± 0.1 nm |
Linearity Range | ≥ 104 |
RI Detector | |
Detection Range | 0.25 ~ 512 μRIU |
Linearity Range | ≥ 600 μRIU |
Response Time | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 sec; |
Cell Volume | 8μL |
Performance of High Performance Liquid Chromatography Instrument
1. High pressure pump with electronic pulse suppression and solvent compression compensation, combined with a two-stage suspended power transmission mechanism to ensure high precision flow output and long service life
2. Two optional gradient modes: binary high pressure and quaternary low pressure.
3. The column oven adopts air bath circulation mode to ensure constant temperature.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2003
Total Annual:
50 Million-100 Million
Employee Number:
1300~1500
Ecer Certification:
Verified Supplier
Anhui Wanyi Science and Technology Cooperated Limited Company founded in 2003, is a professional manufacturer and supplier of analytical instruments with an international vision and operational standards, whose leading products cover chromatography, spectroscopy, mass spectrometry and varieties of i... Anhui Wanyi Science and Technology Cooperated Limited Company founded in 2003, is a professional manufacturer and supplier of analytical instruments with an international vision and operational standards, whose leading products cover chromatography, spectroscopy, mass spectrometry and varieties of i...
Get in touch with us
Leave a Message, we will call you back quickly!