China factories

China factory - Anhui Wanyi Science and Technology Co., Ltd.

Anhui Wanyi Science and Technology Co., Ltd.

  • China,Hefei ,Anhui
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China DAD Detector HPLC Liquid Chromatography Instrument In Quantitative Analysis
China DAD Detector HPLC Liquid Chromatography Instrument In Quantitative Analysis

  1. China DAD Detector HPLC Liquid Chromatography Instrument In Quantitative Analysis
  2. China DAD Detector HPLC Liquid Chromatography Instrument In Quantitative Analysis
  3. China DAD Detector HPLC Liquid Chromatography Instrument In Quantitative Analysis
  4. China DAD Detector HPLC Liquid Chromatography Instrument In Quantitative Analysis
  5. China DAD Detector HPLC Liquid Chromatography Instrument In Quantitative Analysis

DAD Detector HPLC Liquid Chromatography Instrument In Quantitative Analysis

  1. MOQ: 1
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 30 Pieces Per Month
Delivery Time 30 days
Packaging Details Wooden Case
Product Name HPLC Liquid Chromatography Instrument
Detector DAD/UVD/ELSD/FLD/RID
Linearity ≥1.0×104
Wavelength Accuracy 250μL( Standard, with 500μL,1000μL, 2500μL optionals)
Wavelength Range 190-800nm
LOD 5.0×10-9g/mL (naphthalene/methanol)
Brand Name Wayeal
Model Number LC3200
Certification ISO, CE
Place of Origin Anhui, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 30 Pieces Per Month
Delivery Time 30 days Packaging Details Wooden Case
Product Name HPLC Liquid Chromatography Instrument Detector DAD/UVD/ELSD/FLD/RID
Linearity ≥1.0×104 Wavelength Accuracy 250μL( Standard, with 500μL,1000μL, 2500μL optionals)
Wavelength Range 190-800nm LOD 5.0×10-9g/mL (naphthalene/methanol)
Brand Name Wayeal Model Number LC3200
Certification ISO, CE Place of Origin Anhui, China
High Light High Performance Liquid Chromatography Instrument 42MPaDAD Detector Liquid Chromatography InstrumentDAD Detector HPLC Instrument

DAD Detector Quaternary PumpHigh Performance Liquid Chromatography Instruments in Qualitative and Quantitative Analysis
 
Description of Liquid Chromatography Instrument

 

High performance liquid chromatography (HPLC) can be used to separate and identify different large biomolecules such as protein and peptides in a sample. It is based on the pumping of a sample with a solvent (mobile phase) through a column packed with sorbent material (stationary phase) at a high pressure. HPLCinstruments consist of a reservoir of mobilephase, a pump, an injector, a separation column, and adetector. Compounds are separated by injecting a sample mixtureonto the column. The different component in the mixture pass through thecolumn atdifferentiates due to differencesintheirpartition behavior between the mobile phase and thestationary phase. The mobile phase must be degassed to eliminate theformation of air bubbles.

 

Parameters of Liquid Chromatography Instrument

 

DAD Detector Quaternary PumpHigh Performance Liquid Chromatography Instruments in Quantitative Analysis
Physical Specification  
Power Requirements 220V,50HZ
Ambient Temperature 4-40℃
Ambient Humidity 20-85% relative humidity(non-condensing)
System  
Qualitative repeatability(Retention time) RSD≤0.3%
Quantitative repeatability(Area) RSD≤0.6%
Pump  
Flow Rate Range 0.0001-10.000mL/min( increments :0.0001 mL/min)
Max Operating Pressure 42MPa
Pressure Pulsation <0.1MPa( Test condition: 10MPa , at 1.0ml/min methanol)
Flow Accuracy ±0.2%( Test condition: 10MPa , at 1.0ml/min methanol)
Flow Precision RSD≤0.06%( Test condition: 10MPa , at 1.0ml/min methanol)
Gradient Accuracy ±1%
Column Oven  
Temperature Setting Range 5 °C ~ 85 °C
Temperature Stability ≤0.2°C/h
Temperature Controlling Precision ±0.1 °C
Autosampler  
Injection Volume Precision

<0.25%RSD( full loop) ;

<0.5%RSD( partial loop) ;

<1%RSD( no waste)

Linearity >0.999
Cross Contamination(Carry Over) <0.01%
Sample Capacity 120 Samples( 1.5ml vials)
Syringe 250 μL( Standard, with 500μL,1000μL, 2500μL optionals)
Sample Loop 20μL( Standard, with 50μL, 100μL, 200μL optional)

DAD Detector

 
Noise 1.5×10-5Au
Drift ≤1×10-3Au/h
LOD 5.0×10-9g/mL (naphthalene/methanol)
Wavelength Range 190-800nm
Wavelength Reproducibility ≤±0.1 nm
Linearity ≥1.0×104

 

 
 

 

 
 
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2003

  • Total Annual:

    50 Million-100 Million

  • Employee Number:

    1300~1500

  • Ecer Certification:

    Verified Supplier

Anhui Wanyi Science and Technology Cooperated Limited Company founded in 2003, is a professional manufacturer and supplier of analytical instruments with an international vision and operational standards, whose leading products cover chromatography, spectroscopy, mass spectrometry and varieties of i... Anhui Wanyi Science and Technology Cooperated Limited Company founded in 2003, is a professional manufacturer and supplier of analytical instruments with an international vision and operational standards, whose leading products cover chromatography, spectroscopy, mass spectrometry and varieties of i...

+ Read More

Get in touch with us

  • Reach Us
  • Anhui Wanyi Science and Technology Co., Ltd.
  • No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
  • https://www.wayeal-instrument.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement