Packaging Details One piece per wooden case
Name Gas Chromatgraphy Analyzer
Supply voltage 220V±10%
Temperature 18-28℃
Detector ECD
Humidity 40-70%
Qualitative repeatability ≤0.1%
Brand Name Wayeal
Model Number GC6100
Certification ISO, CE
Place of Origin Anhui, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 15 Pieces per month
Delivery Time 30 days Packaging Details One piece per wooden case
Name Gas Chromatgraphy Analyzer Supply voltage 220V±10%
Temperature 18-28℃ Detector ECD
Humidity 40-70% Qualitative repeatability ≤0.1%
Brand Name Wayeal Model Number GC6100
Certification ISO, CE Place of Origin Anhui, China
High Light Liquid Injection Gas Chromatography AnalyzerFID ECD Gas Chromatography AnalyzerLab Analysis Gas Chromatography Analyzer

450 ℃Maximum operating temperatureLiquid Injection Laboratory Analysis FID ECD Gas Chromatography Analyzer

 

 

Product Introduction

 

The GC6000 series gas chromatographs achieve high automation, high efficiency and high precision. A wide range of detectors (FID, FPD, ECD, TCD, RID) are available as options. Three independent circuits, a gas system and three signal outputs are available simultaneously.

 

Product Parameter

 

Liquid Injection Laboratory Analysis FID ECD Gas Chromatography Analyzer
Laboratory Environment  
Supply Voltage 220V±10%
Temperature 18-28℃
Humidity 40-70%
Whole Machine Parameters  
Qualitative Repeatability ≤0.1%
Quantitative Repeatability ≤1.5%
Baseline Noise 0.01pA
Baseline Drift 0.1pA/30min
Inlet Port  
Maximum Operating Temperature 400℃
Flow Control Mode EFC
Control Accuracy 0.001psi
Maximum Shunt Ratio 999:1
Optional Carrier Gas Types N2, H2, He, Ar
Sampler  
Linearity 0.999
Cross-contamination 0.01%
Number of Injection Bits 16 bits
Number of Reagent Bits 3 bits
Column Oven  
Above Room Temperature +4℃- 450℃
Programmed Temperature Rise Rate 40℃/min
Program temperature rise repeatability <0.5%
Minimum Adjustment Amount ≦0.01℃
Temperature Control Accuracy ±0.05℃
Maximum run time 999.9min
Detector (hydrogen flame (FID) detector)  
Maximum operating temperature 450 ℃
Minimum detection limit 2.5pg / s
Linear range ≥ 106


Software

 

1. Self-developed, with software copyright
2. Workstation interface is simple, intuitive, convenient operation process, with a comprehensive audit trail and rights management functions
3. Graphical full counter-control interface, providing suitable real-time analysis of the parameters and analysis results, online modification and acquisition of the working parameters of the components, automatic and rapid data acquisition and post-processing, with instrument-related data and operating conditions traceability function, convenient troubleshooting.
4. Realize the effective integration and control of system components, provide chromatographic detectors, autosampler and other upgrade components for the company's products can be seamlessly added

 

Product Application

 

Application of gas chromatography in health inspection

Air, polycyclic aromatic hydrocarbons, benzene, toluene, benzo(a)ratio, etc.
Residual organochlorine and organophosphorus pesticides in crops, etc.
Food additives such as benzoic acid.
Analysis of biological materials such as body fluids and tissues e.g. amino acids, fatty acids, vitamins, etc.

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2003

  • Total Annual:

    50 Million-100 Million

  • Employee Number:

    1300~1500

  • Ecer Certification:

    Verified Supplier

Anhui Wanyi Science and Technology Cooperated Limited Company founded in 2003, is a professional manufacturer and supplier of analytical instruments with an international vision and operational standards, whose leading products cover chromatography, spectroscopy, mass spectrometry and varieties of i... Anhui Wanyi Science and Technology Cooperated Limited Company founded in 2003, is a professional manufacturer and supplier of analytical instruments with an international vision and operational standards, whose leading products cover chromatography, spectroscopy, mass spectrometry and varieties of i...

+ Read More

Get in touch with us

  • Reach Us
  • Anhui Wanyi Science and Technology Co., Ltd.
  • No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
  • https://www.wayeal-instrument.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement