Payment Terms | T/T |
Supply Ability | 100 units per month |
Delivery Time | 20 days |
Packaging Details | Plywood wooden box |
Product Name | Water Cooled Screw Chiller |
Cooling Temperature | 5℃-35℃ |
Compressor Type | Screw Compressor |
Compressor Brand | Hanbell |
Cooling Capacity | 100-1000kW |
Control System | PLC |
Controller | Microprocessor Control |
Evaporator | Shell and Tube |
Condenser | Shell and Tube |
Noise Level | ≤65dB(A) |
Protection | Compressor Overload, High/Low Pressure, Water Flow, Phase Sequence, Anti-freezing |
Refrigerant | R22/R407C/R134A/R410A |
Voltage | 380V/415V-3N-50Hz/60Hz |
Warranty | 1 Year |
Brand Name | JIALIS |
Model Number | JLSW-140D |
Certification | CE/ISO9001 |
Place of Origin | Dongguan China |
View Detail Information
Explore similar products
JLSW-120D Stable Water Cooled Water Chiller With PLC Microprocessor Control
JLSW-160D 380V 50Hz Water Cooled Screw Chiller With Overheat Protection
JLSW-170D Water Cooled Industrial Chiller Machine 415V 50Hz 60Hz
JLSW-30D Water Cooled Screw Chiller For Agriculture Greenhouse Hydroponics
Product Specification
Payment Terms | T/T | Supply Ability | 100 units per month |
Delivery Time | 20 days | Packaging Details | Plywood wooden box |
Product Name | Water Cooled Screw Chiller | Cooling Temperature | 5℃-35℃ |
Compressor Type | Screw Compressor | Compressor Brand | Hanbell |
Cooling Capacity | 100-1000kW | Control System | PLC |
Controller | Microprocessor Control | Evaporator | Shell and Tube |
Condenser | Shell and Tube | Noise Level | ≤65dB(A) |
Protection | Compressor Overload, High/Low Pressure, Water Flow, Phase Sequence, Anti-freezing | Refrigerant | R22/R407C/R134A/R410A |
Voltage | 380V/415V-3N-50Hz/60Hz | Warranty | 1 Year |
Brand Name | JIALIS | Model Number | JLSW-140D |
Certification | CE/ISO9001 | Place of Origin | Dongguan China |
High Light | 380V Water Cooled Screw Chiller ,415V Water Cooled Screw Chiller ,Multifunction water screw chiller |
JLSW-140D Water Cooled Screw Chiller Beverage Filling Machines, Packaging Machines, Filling Lines, Cooling Equipment
Product Description:
Chillers are widely used in the beverage industry, mainly for refrigeration, cooling and heat preservation. The following are some applications of chillers in the beverage industry:
1. Refrigeration: Chillers can provide cooling water for refrigeration equipment for refrigeration, refrigeration and preservation. In the beverage industry, chillers are often used in refrigeration equipment, such as refrigeration systems for beverage machines, freezers, and cold drink machines.
2. Cooling: The chiller can provide cooling water for the production equipment in the beverage production line, such as beverage filling machines, coolers, etc. Through the circulating flow of cooling water, the heat generated in the equipment can be quickly dissipated to ensure the normal operation of the equipment.
3. Heat preservation: The chiller can provide hot water for the production equipment in the beverage production line, such as heat preservation tanks, water heaters, etc. Through the circulating flow of hot water, the temperature inside the device can be kept stable to ensure the quality and taste of the beverage.
4. Bottle washing: In the beverage production line, bottles need to go through cleaning, disinfection and other processes. The chiller can provide cooling water and cleaning water for the bottle washing machine, ensuring that the bottles can be cooled and cleaned quickly.
In short, the chiller plays an important role in the beverage industry, which can provide the necessary water source for refrigeration, cooling, heat preservation and cleaning, etc., to ensure the normal operation and production efficiency of the beverage production line.
Production Features:
Water-cooled screw machine is a commonly used refrigeration equipment with the following characteristics:
1. High efficiency and energy saving: The water-cooled screw machine adopts twin-screw compressors, which has the characteristics of high efficiency and energy saving. Twin-screw compressors have higher refrigeration efficiency and lower energy consumption than traditional single-screw compressors.
2. Stable and reliable: The operation of the water-cooled screw machine is stable and reliable, and has the characteristics of long life. Its structure is simple, maintenance is convenient, and it can meet the needs of different users.
3. Controllable energy consumption: The water-cooled screw machine can control energy consumption according to actual needs, and realize precise control through the control system, so as to achieve the purpose of energy saving.
4. Environmental protection and energy saving: The water-cooled screw machine adopts environmentally friendly refrigerants, which have low greenhouse effect and zero ozone layer destruction potential, and meet environmental protection requirements.
5. Wide range of application: The water-cooled screw machine has a wide range of applications and can be widely used in air conditioning, cold storage, industrial refrigeration and other fields.
6. Low noise: The noise of the water-cooled screw machine is low, which can meet the needs of noise-sensitive occasions.
7. Strong flexibility: The installation and use of water-cooled screw machines are very flexible, and can be customized and installed according to different places and equipment requirements.
In short, the water-cooled screw machine has the advantages of high efficiency and energy saving, stability and reliability, controllable energy consumption, environmental protection and energy saving, wide application range, low noise, and strong flexibility. It can meet the needs of different users and is a very practical refrigeration equipment.
Working Principle:
The working principle of the water-cooled screw chiller mainly includes four processes of compression, condensation, expansion and evaporation.
1.Compression process: Under the action of the screw compressor, the refrigerant is compressed into a high-temperature and high-pressure gas, while absorbing the surrounding heat.
2.Condensation process: High-temperature and high-pressure refrigerant enters the condenser, and through contact with cold water or surrounding air, it emits heat and cools into a high-pressure liquid.
3.Expansion process: The high-pressure liquid refrigerant enters the evaporator through the throttle valve, the pressure drops suddenly, and the liquid refrigerant expands into a low-pressure refrigerant while absorbing the surrounding heat.
4.Evaporation process: The low-pressure refrigerant enters the evaporator, absorbs surrounding heat through contact with water or air, turns into a low-temperature and low-pressure refrigerant, and returns to the compression process.
Through such a cycle process, the water-cooled screw chiller can deliver cold water to the area that needs to be cooled to achieve the effects of cooling, dehumidification and keeping the air fresh. At the same time, the water-cooled screw chiller will also emit a certain amount of heat, which needs to be dissipated through cooling towers or other heat dissipation equipment to ensure the normal operation of the system.
Techinical Parameters:
Model | JLSW-30D | JLSW-40D | JLSW-50D | JLSW-60D | JLSW-80D | JLSW-100D | JLSW-120D | JLSW-150D | ||
Cooling capacity | KW/h | 100 | 140 | 180 | 200 | 260 | 370 | 430 | 550 | |
TR | 28.5 | 39.8 | 51.2 | 56.9 | 73.9 | 105.2 | 122.3 | 156.4 | ||
Temperature range | 5℃~35℃(Below 0℃ can be customized) | |||||||||
Power supply | 3N-380V/415 50HZ/60HZ | |||||||||
Compressor | Type | Semi-hermetic screw | ||||||||
Power | KW | 22 | 30 | 36 | 41 | 56 | 80 | 93 | 118 | |
electric current | A | 39 | 51 | 65 | 71 | 95 | 135 | 156 | 198 | |
Refrigerant | Type | R22/R407c | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 16.5 | 22.2 | 27.5 | 33.4 | 44.4 | 55.6 | 66.5 | 82.6 | |
Evaporator | shell and tube | |||||||||
Flow | m³/h | 17.2 | 22.4 | 29.3 | 33 | 43.9 | 64.2 | 75.2 | 95.3 | |
Diameter | inch | G2.5" | G3" | G3" | G3" | G3" | G4" | G4" | G4" | |
Compressor | Type | shell and tube | ||||||||
Flow | m³/h | 22.4 | 29.2 | 35.2 | 42.9 | 57.8 | 84.3 | 101.1 | 123.9 | |
Diameter | inch | G2.5" | G3" | G3" | G3" | G3" | G4" | G4" | G4" | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 2200 | 2250 | 2350 | 2450 | 2500 | 2900 | 3000 | 3000 |
W | mm | 800 | 800 | 800 | 900 | 900 | 900 | 1500 | 1500 | |
H | mm | 1500 | 1600 | 1650 | 1750 | 1800 | 1850 | 1500 | 1550 | |
Unit weight | Kg | 960 | 990 | 1260 | 1380 | 1520 | 1830 | 2150 | 2580 |
Model | JLSW-170D | JLSW-200D | JLSW-230D | JLSW-260D | JLSW-280D | JLSW-310D | JLSW-350D | JLSW-400D | ||
Cooling capacity | KW/h | 620 | 710 | 830 | 930 | 1020 | 1130 | 1270 | 1530 | |
TR | 176.3 | 201.9 | 236 | 264.4 | 290 | 321.3 | 361.1 | 435 | ||
Temperature range | 5℃~35℃(Below 0℃ can be customized) | |||||||||
Power supply | 3N-380V/415 50HZ/60HZ | |||||||||
Compressor | Type | Semi-hermetic screw | ||||||||
Power | KW | 130 | 150 | 175 | 200 | 225 | 250 | 281 | 325 | |
electric current | A | 218 | 253 | 295 | 335 | 390 | 432 | 480 | 553 | |
Refrigerant | Type | R22/R407c | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 93.8 | 111.2 | 126.8 | 144.1 | 155.4 | 170.9 | 193.2 | 220.9 | |
Evaporator | shell and tube | |||||||||
Flow | m³/h | 108.6 | 126.3 | 144.9 | 163.8 | 176.4 | 196.5 | 222.4 | 252.6 | |
Diameter | inch | G5" | G5" | G6" | G6" | G8" | G8" | G8" | G8" | |
Compressor | Type | shell and tube | ||||||||
Flow | m³/h | 141.1 | 166.2 | 190.9 | 215.8 | 232.4 | 258.6 | 290.8 | 333.2 | |
Diameter | inch | G5" | G5" | G6" | G6" | G8" | G8" | G8" | G8" | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 3600 | 3600 | 3600 | 3650 | 3650 | 3700 | 3700 | 4200 |
W | mm | 1500 | 1500 | 1500 | 1600 | 1650 | 1750 | 1750 | 1750 | |
H | mm | 1650 | 1650 | 1700 | 1700 | 1700 | 1750 | 1800 | 1800 | |
Unit weight | Kg | 3050 | 3200 | 3450 | 3780 | 4060 | 4330 | 4600 | 4820 |
Application Industry:
Chillers are widely used in the beverage industry, mainly for the following aspects:
1. Cooling during beverage production: In the process of beverage production, some raw materials or mixtures need to be cooled. The chiller can provide cooling water to control the temperature of beverages and ensure the stability of product quality and taste. For example, in fruit juice production, rapid cooling of the juice preserves its freshness and taste.
2. Temperature control in the beverage filling process: In the beverage filling process, it is necessary to control the temperature of the beverage to meet the filling requirements. The chiller can control the temperature of the filling equipment by providing cooling water to ensure that the beverage maintains a suitable temperature during the filling process to avoid problems such as bubbles, foam or deterioration.
3. Beverage bottle cooling: After the beverage is filled, the beverage bottle needs to be cooled to improve the quality and shelf life of the product. Chillers can reduce the temperature of beverage bottles by providing cooling water or cold air to speed up the cooling of products, thereby reducing bacterial growth and extending the shelf life of products.
4. Temperature control in the beverage packaging process: In the beverage packaging process, the temperature of the packaging material needs to be controlled to ensure the quality and airtightness of the packaging. Chillers can control the temperature of packaging equipment by providing cooling water or cooling gas, maintain the stability of packaging materials, and ensure the quality of packaging.
In short, chillers play an important role in the beverage industry and are mainly used in cooling, temperature control and cooling of beverage bottles and packaging materials during beverage production. These applications can ensure the quality, taste and shelf life of beverage products, and improve production efficiency and stability.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Air Cooled Chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
What are the common application cases of chillers in the beverage industry?
Chillers have the following common application cases in the beverage industry:
1. Beverage production line: Chillers are widely used in the cooling process in beverage production lines. In the production of fruit juice, carbonated beverages, tea beverages, etc., the cooling water provided by the chiller is used to control the temperature of the product to ensure the stability of product quality and taste.
2. Beverage filling equipment: The chiller is used to provide cooling water for beverage filling equipment to control the temperature during the filling process. During the filling process of bottled water, fruit juice, soft drinks, etc., the chiller helps maintain the appropriate temperature of the beverage, prevents the generation of air bubbles and foam, and ensures product quality.
3. Beverage bottle cooling: The chiller is used for cooling of beverage bottles. After the beverage is filled, the bottle needs to go through a cooling process to reduce the temperature and increase the shelf life of the product. The chiller quickly cools beverage bottles by providing cooling water or cold air to ensure the quality and taste of the product.
4. Packaging material cooling: Chillers are used to control the temperature of packaging materials during beverage packaging. During the filling and sealing process, the chiller provides cooling water or cooling gas to maintain the stability of the packaging material and ensure the quality and tightness of the package.
5. Beverage tempering: The chiller can also be used for beverage tempering. Under specific needs, such as cooling of hot drinks, heating of cold drinks, etc., the chiller can meet different needs by adjusting the temperature of the water supply.
These are common application examples of chillers in the beverage industry. By providing cooling water or cooling air, chillers can help control temperature, maintain product quality, and increase production efficiency and stability.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2008
Total Annual:
10 million-15 million
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a... Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a...
Get in touch with us
Leave a Message, we will call you back quickly!