Payment Terms | T/T |
Supply Ability | 500 units per month |
Delivery Time | 15 days |
Packaging Details | Plywood wooden box |
Product Name | Low Temperature Chiller |
Compressor Type | Scroll |
Evaporator | Water tank coil/Shell and Tube/Plate Heat Exchanger |
Condenser | Finned |
Control System | PLC |
Controller | Microprocessor |
Cooling Method | Air/Water/Glycol |
Material | Stainless Steel |
Temperature Range | -30℃~+35℃ |
Warranty | 12 months |
Brand Name | JIALIS |
Model Number | JLSFD-10HP |
Certification | CE/ISO |
Place of Origin | Dongguan China |
View Detail Information
Explore similar products
JLSW-40D Low Temperature Chiller , Screw Type Ethylene Glycol Chiller
JLSW-170D Low Temperature Chiller , Screw Type Glycol Water Chiller
JLSFD-20HP Low Temperature Chiller , Air Cooled Water Chillers 50HZ 60HZ
JLSFD-12HP Industrial Low Temperature Water Chiller Air Cooled Scroll Type
Product Specification
Payment Terms | T/T | Supply Ability | 500 units per month |
Delivery Time | 15 days | Packaging Details | Plywood wooden box |
Product Name | Low Temperature Chiller | Compressor Type | Scroll |
Evaporator | Water tank coil/Shell and Tube/Plate Heat Exchanger | Condenser | Finned |
Control System | PLC | Controller | Microprocessor |
Cooling Method | Air/Water/Glycol | Material | Stainless Steel |
Temperature Range | -30℃~+35℃ | Warranty | 12 months |
Brand Name | JIALIS | Model Number | JLSFD-10HP |
Certification | CE/ISO | Place of Origin | Dongguan China |
High Light | Low Temperature Chiller Air Cooled ,Industrial Low Temperature Chiller ,Scroll Air Cooled Industrial Chiller |
JLSFD-10HP Air-Cooled Low Temperature Chiller Spindle Cooling , CNC Machine Tools, Sand Mills, Welding Machines
Production Description:
The air-cooled low-temperature chiller is a low-temperature refrigeration equipment that uses air-cooled cooling. It is mainly composed of compressor, condenser, evaporator, electric control system, etc., and realizes the purpose of cooling and cooling through the change of refrigerant in the cycle.
At the same time, the air-cooled low-temperature chiller adopts an air-cooled cooling method, which dissipates heat to the surrounding air through a fan, without an additional water circulation system, saving water resources, reducing water treatment costs, and improving the cooling efficiency of the equipment .
Production Features:
The air-cooled low-temperature chiller has the following characteristics:
1.Low-temperature refrigeration: Air-cooled low-temperature chillers can realize low-temperature refrigeration, which can meet the needs of some special industries for low-temperature refrigeration, such as medicine, food and other industries.
2.High efficiency and energy saving: Air-cooled cooling method is adopted, no additional water circulation system is required, water resources are saved, water treatment costs are reduced, and the cooling efficiency of the equipment is also improved.
3.Easy to operate: It has an intelligent control system, which can realize automatic and intelligent operation and control, and is easy to operate.
4.Wide range of applications: Air-cooled low-temperature chillers can be used in many industries, such as medicine, food, chemical and other industries, and have broad application prospects.
In short, the air-cooled low-temperature chiller is a low-temperature refrigeration equipment, which has the characteristics of low-temperature refrigeration, high efficiency and energy saving, easy operation, and wide application. It is suitable for the low-temperature refrigeration needs of many industries.
Working Principle:
Specifically, the working principle of the air-cooled low-temperature chiller is:
1.The compressor sucks in low-temperature and low-pressure refrigerant and compresses it into a high-temperature and high-pressure gas.
2.The high-temperature and high-pressure gas enters the condenser, releases heat into the air through the radiator, and turns into a high-temperature and high-pressure liquid.
3.The high-temperature and high-pressure liquid enters the evaporator, exchanges heat with the outside through the evaporator, and turns into low-temperature and low-pressure steam.
4.The low-temperature and low-pressure steam enters the compressor again, and the cycle repeats.
Techinical Parameters:
Model | JLSF-3HP | JLSF-5HP | JLSF-10HP | JLSF-20HP | JLSF-30HP | JLSF-40HP | JLSF-50HP | JLSF-60HP | ||
Cooling capacity | KW/h | 9.3 | 15.5 | 31 | 77.5 | 93 | 124 | 155 | 186 | |
Kcal/h | 8,100 | 13,500 | 27,000 | 61,683 | 74,992 | 97,675 | 116,521 | 156,249 | ||
Temperature range | -30℃~35℃ | |||||||||
Power supply | 1N-220V 50HZ/60HZ 3N-380V/415V 50HZ/60HZ | |||||||||
Total power | KW | 6.2 | 10.3 | 19.8 | 22.75 | 28.3 | 39.2 | 46.75 | 56.1 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||
Power | KW | 2.25 | 3.75 | 7.5 | 15 | 22.5 | 30 | 37.5 | 45 | |
Circulating pump | Power | KW | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | 4 | 5.5 |
Head | m | 21.5 | 21.5 | 22 | 22 | 25 | 25 | 25 | 26 | |
Refrigerant | Type | R22/R407c/R404a/R410a | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 7.2 | 9.1 | 12.2 | 15.3 | 18.6 | 24.5 | 30.6 | 36.8 | |
Evaporator | Flow | m³/h | 5.81 | 7.6 | 10.16 | 12.34 | 15.2 | 19.53 | 23.3 | 30.52 |
water capacity | m³/h | 0.18 | 0.21 | 0.28 | 0.32 | 0.32 | 0.61 | 0.66 | 0.72 | |
Diameter | inch | 1.5" | 2" | 2.5" | 3" | |||||
Condensator | Type | Efficient brass sets corrugated aluminum fin | ||||||||
Fan | Type | Axial flow | ||||||||
air volume | m³/h | 12000 | 15000 | 20000 | 25000 | 30000 | 40000 | 50000 | 60000 | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 1400 | 1750 | 2000 | 2000 | 2200 | 2000 | 2000 | 2400 |
W | mm | 725 | 750 | 900 | 900 | 900 | 1800 | 1800 | 1800 | |
H | mm | 1450 | 1500 | 1770 | 1770 | 1770 | 2200 | 2300 | 2300 | |
Unit weight | Kg | 370 | 480 | 590 | 590 | 880 | 1000 | 1280 | 1420 |
Application Industry:
Cryogenic chillers are commonly used in industries and applications that require operation at low temperatures. The following are some common low temperature chiller application industries:
1.Refrigeration and air-conditioning industry: Low-temperature chillers can be used in refrigeration and air-conditioning systems to provide cooling services for buildings, commercial facilities, and industrial equipment.
2.Food processing industry: Low-temperature chillers can be used in food processing industries, such as freezing, refrigeration, quick freezing and cooling.
3.Medical industry: Low-temperature chillers can be used for refrigeration equipment in the pharmaceutical and biotechnology industries, such as low-temperature refrigerators, medical refrigerators, refrigerated trucks, and freeze dryers.
4.Chemical industry: Low temperature chillers can be used in chemical and pharmaceutical industries, such as synthesis reactions, cooling and freezing, etc.
5.Electronics industry: Low-temperature chillers can be used in semiconductor manufacturing and testing equipment in the electronics industry, such as low-temperature processing and testing of semiconductor materials.
6.Aerospace industry: Cryogenic chillers can be used for testing equipment and refrigeration equipment in the aerospace industry, such as cryogenic test chambers and refrigeration equipment for propulsion systems.
7.Metallurgical industry: Low-temperature chillers can be used for refrigeration equipment in the metallurgical industry, such as cooling and freezing in metallurgical reactions.
In conclusion, low temperature chillers are widely used in many industries and applications to meet the needs of low temperature refrigeration in different fields.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Air Cooled Chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
Precautions:
The low-temperature chiller is a special refrigeration equipment, and the following items should be paid attention to when using it:
1.Safety precautions: The use of low-temperature chillers involves low-temperature refrigerants and high-pressure refrigerants, and relevant safety regulations and operating procedures must be followed, such as wearing protective clothing and protective gloves.
2.Regular maintenance: Low-temperature chillers must be regularly maintained and maintained, including cleaning the refrigeration system, replacing filters, and checking the electrical system, etc., to ensure the normal operation of the equipment and extend the life of the equipment.
3.Temperature control: When the low-temperature chiller is used, the temperature of the equipment must be well controlled to avoid over-cooling or overheating, which will affect the performance and life of the equipment.
4.Air circulation: When using low-temperature chillers, it is necessary to ensure that the air circulation around the equipment is good to avoid overheating or overcooling of the equipment, and at the same time prevent the equipment from being polluted by external substances.
5.Operation skills: The operation of low-temperature chillers requires certain professional knowledge and skills, such as understanding the characteristics of refrigerants, mastering the operation methods and adjustment methods of the equipment, etc.
6.Environmental protection precautions: In the use and maintenance of low-temperature chillers, it is necessary to pay attention to environmental protection issues, such as correct disposal of waste refrigerants and waste equipment components, etc., to reduce the impact on the environment.
In short, when using low-temperature chillers, you need to pay attention to many aspects, including safety, maintenance, temperature control, air circulation, operating skills and environmental protection, to ensure the normal operation of the equipment and extend the life of the equipment.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2008
Total Annual:
10 million-15 million
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a... Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a...
Get in touch with us