Payment Terms | T/T |
Supply Ability | 200 units per month |
Delivery Time | 20 days |
Packaging Details | Plywood wooden box |
Name | Explosion Proof Water Chiller |
Compressor | Scroll |
Evaporator | Shell and Tube |
Condenser | Finned |
Control System | PLC |
Controller | Microprocessor |
Protection | High/Low Pressure, Overload, Phase Sequence, Anti-Freezing |
Noise Level | 60dB |
Protection Level | IP54 |
Warranty | 1 Year |
Brand Name | JIALIS |
Model Number | JLSF-15AD |
Certification | CE/ISO9001 |
Place of Origin | Dongguan China |
View Detail Information
Explore similar products
JLSW-30AD Explosion Proof Water Chiller , Screw Water Cooled Chiller For Oil
JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical
JLSF-10AD Industrial Explosion Proof Water Chiller For Petrochemical Aerospace
JLSF-12AD IP54 Air Cooled Water Chiller Anti Corrosive Toxic Proof
Product Specification
Payment Terms | T/T | Supply Ability | 200 units per month |
Delivery Time | 20 days | Packaging Details | Plywood wooden box |
Name | Explosion Proof Water Chiller | Compressor | Scroll |
Evaporator | Shell and Tube | Condenser | Finned |
Control System | PLC | Controller | Microprocessor |
Protection | High/Low Pressure, Overload, Phase Sequence, Anti-Freezing | Noise Level | 60dB |
Protection Level | IP54 | Warranty | 1 Year |
Brand Name | JIALIS | Model Number | JLSF-15AD |
Certification | CE/ISO9001 | Place of Origin | Dongguan China |
High Light | Medicine Explosion Proof Water Chiller ,Petroleum Explosion Proof Water Chiller ,IP54 Water Chiller Machine |
JLSF-15AD Air Cooled Explosion-Proof Screw Chiller Chemicals, Petroleum, Natural Gas, Medicine
Product Description:
The air-cooled explosion-proof chiller is an explosion-proof chiller with the characteristics of explosion-proof design, air cooling, environmental protection and energy saving, high-efficiency performance and convenient installation. It is suitable for places requiring explosion-proof measures, such as chemical industry, petroleum, natural gas, medicine and other fields .
Production Features:
The main features of the air-cooled explosion-proof chiller include:
1. Explosion-proof design: The air-cooled explosion-proof chiller adopts an explosion-proof design, which can operate safely in flammable and explosive places to ensure production safety.
2. Air cooling: The air-cooled explosion-proof chiller adopts air cooling method and does not require water source, which reduces water consumption and discharge, and also reduces the cost of water treatment.
3. Environmental protection and energy saving: The air-cooled explosion-proof chiller uses environmentally friendly refrigerants and an efficient refrigeration system, which can reduce the impact on the environment and reduce energy consumption while ensuring the cooling effect.
4. High-efficiency performance: The air-cooled explosion-proof chiller adopts a high-efficiency compressor and refrigeration system, which can reduce energy consumption and operating costs while ensuring the cooling effect.
5. Easy installation: The air-cooled explosion-proof chiller is easy to install, does not require water source, and is suitable for places where water source cannot be provided.
Working Principle:
The air-cooled explosion-proof chiller mainly realizes refrigeration through a refrigeration system composed of a compressor, a
condenser, an evaporator and a fan. It works as follows:
1. The compressor compresses the low-temperature and low-pressure refrigerant gas into a high-temperature and high-pressure gas, which is then sent to the condenser.
2. The refrigerant gas in the condenser is cooled and condensed into a high-pressure liquid by exchanging heat with the outside air.
3. The high-pressure liquid is decompressed through the expansion valve, becomes a low-temperature low-pressure liquid, and then enters the evaporator.
4. The refrigerant liquid in the evaporator exchanges heat with the outside air, thereby absorbing the heat in the air, and evaporating the refrigerant liquid into a low-temperature and low-pressure gas.
5. The low-temperature and low-pressure gas enters the compressor to start a new refrigeration cycle.
At the same time, the air-cooled explosion-proof chiller also introduces air into the condenser and evaporator through the fan for cooling and heat exchange. Due to the air cooling method, no water source is required, and it is suitable for places where no water source is available. At the same time, the air-cooled explosion-proof chiller adopts an explosion-proof design, which can operate safely in flammable and explosive places to ensure production safety.
① Compressor | ⑤ Evaporator | ⑨ Temperature sensor | ⑬ Bypass valve |
② Condenser | ⑥ Ball valve | ⑩ Water tank | ⑭ Low voltage controller |
③ Filter drier | ⑦ Antifreeze switch | ⑪ Water pump pressure gauge | ⑮ High voltage controller |
④ Expansion valve | ⑧ Float switch | ⑫ Water pump | ⑯ Fan |
Techinical Parameters:
Model | JLSF- 30AD | JLSF- 40AD | JLSF- 50AD | JLSF- 60AD | JLSF- 70AD | JLSF- 80AD | JLSF- 90AD | JLSF- 100AD | JLSF- 110AD | ||
Cooling capacity | KW/h | 94.8 | 126.4 | 158.0 | 189.6 | 221.2 | 252.8 | 284.4 | 316.0 | 347.6 | |
TR | 84,000 | 112,000 | 140,000 | 168,000 | 196,000 | 224,000 | 252,000 | 280,000 | 308,000 | ||
Temperature range | 5℃~35℃(Below 0℃ can be customized) | ||||||||||
Power supply | 3N-380V/415V 50HZ/60HZ | ||||||||||
Total power | KW | 24.8 | 33.7 | 41.5 | 45.2 | 57.4 | 62 | 69 | 72.5 | 83.6 | |
Running current | A | 41 | 56.5 | 69.6 | 75.9 | 96.5 | 86.7 | 116.2 | 122 | 111.3 | |
Chilled water | m³/h | 15 | 19.6 | 24.2 | 29 | 35 | 40 | 45 | 50.2 | 53.8 | |
compressor | type | Semi-hermetic screw type | |||||||||
Start method | Y-△ | ||||||||||
capacity adjustment | 0,25,50,75,100 | ||||||||||
input power | KW | 23.3 | 30.7 | 38.5 | 42.2 | 51.4 | 56 | 63 | 66.3 | 73 | |
Frozen oil | type | HBR-A01 | |||||||||
filling volume | L | 7 | 7 | 8 | 12 | 16 | 16 | 16 | 16 | 18 | |
refrigerant | type | R-22/R407C | |||||||||
control method | Temperature Sensing External Pressure Equalizing Expansion Valve | ||||||||||
Evaporator | filling volume | KG | 16 | 22 | 27 | 32 | 36 | 42 | 46 | 52 | 56 |
type | shell and tube | ||||||||||
condenser | Diameter | mm | DN65 | DN80 | DN80 | DN80 | DN80 | DN100 | DN100 | DN100 | DN125 |
type | High-efficiency copper-sleeved aluminum-fin type + low-noise external rotor fan | ||||||||||
Cooling air volume | m³/h | 28000 | 36000 | 45000 | 5500 | 63000 | 74000 | 83000 | 92000 | 102000 | |
protective device | High and low voltage switch, antifreeze protection, soluble plug, safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | ||||||||||
Dimensions | L | mm | 2200 | 2300 | 2500 | 2800 | 2800 | 2910 | 3100 | 3150 | 3150 |
W | mm | 1100 | 1100 | 1200 | 1200 | 1800 | 2050 | 2050 | 2050 | 2050 | |
H | mm | 1820 | 2030 | 2030 | 2030 | 2100 | 2100 | 2100 | 2100 | 2100 | |
weight | KG | 920 | 1120 | 1350 | 1560 | 1780 | 1920 | 2230 | 2450 | 2720 |
Model | JLSF-120AD | JLSF- 130AD | JLSF-150AD | JLSF-160AD | JLSF-180AD | JLSF-200AD | JLSF- 240AD | JLSF-260AD | JLSF-300AD | ||
Cooling capacity | KW/h | 379.2 | 410.8 | 474.0 | 505.6 | 568.8 | 632.0 | 758.4 | 821.6 | 948.0 | |
TR | 336,000 | 364,000 | 420,000 | 448,000 | 504,000 | 560,000 | 672,000 | 728,000 | 840,000 | ||
Temperature range | 5℃~35℃(Below 0℃ can be customized) | ||||||||||
Power supply | 3N-380V/415V 50HZ/60HZ | ||||||||||
Total power | KW | 149 | 169 | 195.1 | 204.8 | 240 | 247.5 | 282 | 309.4 | 364.5 | |
Running current | A | 88.6 | 100.5 | 114.8 | 120.5 | 141.6 | 145.6 | 165.5 | 182 | 214.4 | |
Chilled water | m³/h | 59 | 65 | 74 | 79 | 90 | 101 | 119 | 130 | 152 | |
compressor | type | Semi-hermetic screw type | |||||||||
Start method | Y-△ | ||||||||||
capacity adjustment | 0,25,50,75,100 | ||||||||||
input power | KW | 79.6 | 88.5 | 102.8 | 108.5 | 126.6 | 130.6 | 150.5 | 167 | 199.4 | |
Frozen oil | type | HBR-A01 | |||||||||
filling volume | L | 18 | 18 | 23 | 24 | 24 | 28 | 32 | 32 | 36 | |
refrigerant | type | R-22/R407C | |||||||||
control method | Temperature Sensing External Pressure Equalizing Expansion Valve | ||||||||||
Evaporator | filling volume | KG | 62 | 66 | 75 | 80 | 92 | 103 | 121 | 126 | 150 |
type | shell and tube | ||||||||||
condenser | Diameter | mm | DN1250 | DN150 | DN200 | ||||||
type | High-efficiency copper-sleeved aluminum-fin type + low-noise external rotor fan | ||||||||||
Cooling air volume | m³/h | 112000 | 122000 | 141000 | 150000 | 169000 | 189000 | 223000 | 245000 | 285000 | |
protective device | High and low voltage switch, antifreeze protection, soluble plug, safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | ||||||||||
Dimensions | L | mm | 3500 | 3800 | 4120 | 4250 | 4680 | 4680 | 5230 | 5630 | 6550 |
W | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2210 | |
H | mm | 2120 | 2120 | 2120 | 2120 | 2120 | 2120 | 2120 | 2120 | 2150 | |
weight | KG | 3050 | 3360 | 3670 | 3550 | 4120 | 4230 | 4650 | 5570 | 7420 |
Application Industry:
The air-cooled explosion-proof chiller is mainly suitable for places requiring explosion-proof measures, such as chemical industry, petroleum, natural gas, medicine and other fields. The specific scope of application is as follows:
1.Chemical industry: Inflammable and explosive chemical substances are often involved in chemical production, so it is necessary to use explosion-proof chillers for cooling to ensure production safety.
2.Oil and natural gas: In the process of oil and natural gas extraction, flammable and explosive gases are often involved, so explosion-proof chillers are required for cooling to ensure production safety.
3.Medicine: Inflammable and explosive chemicals are often involved in pharmaceutical production, so explosion-proof chillers are required for cooling to ensure production safety.
4.Other industries: Explosion-proof chillers can also be used in other industries, such as mining, energy, military and other fields, to cool equipment involving flammable and explosive substances, so as to ensure production safety.
In short, the air-cooled explosion-proof chiller is mainly suitable for places that require explosion-proof measures, such as chemical industry, petroleum, natural gas, medicine and other fields. Air-cooled explosion-proof chillers can provide safe and reliable cooling solutions for these industries, ensuring production safety and equipment stability.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Air Cooled Chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
Maintenance Method:
The air-cooled explosion-proof chiller is an important refrigeration equipment. In order to ensure its normal operation and prolong its service life, regular maintenance is required. The following are the matters needing attention in the maintenance of air-cooled explosion-proof chillers:
1.Regular cleaning: It is necessary to regularly clean the air-cooled explosion-proof chiller, including cleaning the condenser and evaporator and other components, to ensure that its surface is clean and free from dirt or dust, so as to ensure the cooling effect.
2.Clean the filter screen regularly: The filter screen needs to be cleaned regularly to avoid dust and dirt from clogging the filter screen and affecting the cooling effect.
3.Regularly replace the refrigerant: The refrigerant needs to be replaced regularly to ensure its cooling effect.
4.Regular inspection of pipes: Regular inspection of pipes is required to ensure that they are not leaking or damaged, so as to avoid refrigerant leakage and affect cooling effect and safety.
5.Regular inspection of electrical components: Regular inspection of electrical components is required to ensure good electrical connections and normal operation of electrical equipment to avoid safety accidents caused by electrical failures.
6.Regularly check the compressor: It is necessary to check the compressor regularly to ensure its normal operation and avoid safety accidents caused by compressor failure.
7.Regularly check the surrounding environment of the unit: It is necessary to regularly check the surrounding environment of the unit to ensure that there are no sundries or obstacles to avoid affecting the normal operation of the unit.
In short, the maintenance of the air-cooled explosion-proof chiller is very important. It needs regular cleaning, replacement of refrigerant, inspection of pipelines, electrical components and compressors, etc. to ensure its normal operation and safety.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2008
Total Annual:
10 million-15 million
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a... Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a...
Get in touch with us
Leave a Message, we will call you back quickly!