China JLSF-6HP Air Cooling Water Chiller Machine For Vacuum Coating Electroplating
China JLSF-6HP Air Cooling Water Chiller Machine For Vacuum Coating Electroplating

  1. China JLSF-6HP Air Cooling Water Chiller Machine For Vacuum Coating Electroplating
  2. China JLSF-6HP Air Cooling Water Chiller Machine For Vacuum Coating Electroplating

JLSF-6HP Air Cooling Water Chiller Machine For Vacuum Coating Electroplating

  1. MOQ: 1 set
  2. Price: Discuss
  3. Get Latest Price
Payment Terms T/T
Supply Ability 600 units per month
Delivery Time 5 days
Packaging Details Plywood wooden box
Product Name Air Cooled Water Chiller
Application Industrial/Commercial
Controller Microprocessor/PLC
Compressor Type Scroll/Semi-Hermetic/Hermetic
Evaporator Water Tank Coil/Shell and Tube/Plate Heat Exchanger
Condenser Finned
Condenser Fans Axial/Centrifugal
Sound Level 60-65dB(A)
Pump Centrifugal
Refrigerant R22/R407C/R134A/R410A/R404A
Protection High/Low Pressure/Overload/Phase Sequence/Anti-freezing
Warranty 12 months
Brand Name JIALIS
Model Number JLSF-6HP
Certification CE/ISO
Place of Origin Dongguan China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 600 units per month
Delivery Time 5 days Packaging Details Plywood wooden box
Product Name Air Cooled Water Chiller Application Industrial/Commercial
Controller Microprocessor/PLC Compressor Type Scroll/Semi-Hermetic/Hermetic
Evaporator Water Tank Coil/Shell and Tube/Plate Heat Exchanger Condenser Finned
Condenser Fans Axial/Centrifugal Sound Level 60-65dB(A)
Pump Centrifugal Refrigerant R22/R407C/R134A/R410A/R404A
Protection High/Low Pressure/Overload/Phase Sequence/Anti-freezing Warranty 12 months
Brand Name JIALIS Model Number JLSF-6HP
Certification CE/ISO Place of Origin Dongguan China
High Light JLSF-6HP Air Cooling Water ChillerVacuum Coating Air Cooling Water ChillerElectroplating Oxidation cooling chiller machine

JLSF-6HP Air Cooled Water Chiller Coating Machine, Vacuum Coating, Electroplating Oxidation


Product Description:


The vacuum coating chiller is a chiller used to cool the vacuum coating equipment. Its main function is to control the temperature of the reaction chamber, target material, vacuum pump and other equipment to ensure the stability of the equipment and the quality of the film.




 

Production Features:


The main features of the vacuum coating chiller are:

 

1. High-precision temperature control: The vacuum coating chiller can accurately control the temperature of the reaction chamber, target material and vacuum pump and other equipment by controlling the temperature and flow of cooling water, so as to ensure the stability of the equipment and the quality of the film.

 

2. Efficient cooling: The vacuum coating chiller can quickly reduce the temperature of the reaction chamber, target material, vacuum pump and other equipment through circulating water, and improve cooling efficiency and production efficiency.

 

3. Compact equipment structure: Vacuum coating chillers usually adopt a compact structure design, occupying a small space, and are easy to install and use.

 

4. Easy to operate: The operation of the vacuum coating chiller is relatively simple, only need to adjust the temperature and flow of cooling water to realize the control of the equipment.

 

5. Energy saving and environmental protection: The vacuum coating chiller adopts an energy-saving and environmental protection design, which can reduce energy consumption and environmental pollution.

 

Vacuum coating chillers have been widely used in electronics, optoelectronics, aviation, chemical and other industries. They can provide a stable cooling water source for vacuum coating equipment, ensure the stability of the equipment and the quality of the film, improve production efficiency and reduce production costs.

 

 

Working Principle:


The main components of an air-cooled chiller include a compressor, an air condenser, an expansion valve, and an evaporator. Here is a basic overview of its workflow:

1.The compressor takes in low-pressure, low-temperature refrigerant gas and compresses it into high-pressure, high-temperature gas.
 

2.This high-temperature, high-pressure refrigerant gas enters the air condenser, exchanges heat with the ambient air, and discharges heat to the environment, while the refrigerant condenses from a gaseous state to a liquid state.
 

3.The high-pressure refrigerant liquid passes through the expansion valve, the pressure suddenly drops, and it turns into a low-pressure and low-temperature refrigerant liquid.
 

4.The low-temperature and low-pressure refrigerant liquid enters the evaporator, absorbs indoor heat, evaporates into a gaseous state by itself, and the indoor temperature drops to achieve the purpose of refrigeration.
 

5.The refrigerant gas is sucked into the compressor again to complete a cycle.
 

The advantages of air-cooled chillers include simple installation, no need for cooling towers and cooling water pumps, and low maintenance costs. However, its efficiency is lower than that of water-cooled chillers, especially at high ambient temperatures, and its efficiency will be further reduced

① Compressor ⑤ Evaporator ⑨ Temperature sensor ⑬ Bypass valve
② Condenser ⑥ Ball valve ⑩ Water tank ⑭ Low voltage controller
③ Filter drier ⑦ Antifreeze switch ⑪ Water pump pressure gauge ⑮ High voltage controller
④ Expansion valve ⑧ Float switch ⑫ Water pump

⑯ Pressure relief valve

 

 

 

Techinical Parameters:

 

Model JLSF-1HP JLSF-2HP JLSF-3HP JLSF-4HP JLSF-5HP JLSF-6HP JLSF-8HP JLSF-10HP
Cooling capacity KW/h 3.1 6.2 9.3 12.4 15.5 18.6 24.8 31
Kcal/h 2,700 5,400 8,100 10,800 13,500 16,200 21,600 27,000
Temperature range 5℃-35℃(Below 0℃ can be customized)
Power supply 1PH-220V 50HZ/60HZ     3PH-380V/415V 50HZ/60HZ
Total power KW 1.21 2.03 2.84 3.7 4.5 5.7 7.33 8.83
Compressor Type   Hermetic scroll type or piston
Power KW 0.75 1.50 2.25 3.00 3.75 4.50 6.00 7.50
Circulating pump Power KW 0.375 0.375 0.375 0.375 0.75 0.75 0.75 1.5
Head m 22 22 22 22 23 23 23 21.5
Refrigerant Type   R22/R407c/R134a/R410a
Control method   Temperature Sensing External Pressure Equalizing Expansion Valve
filling volume Kg 0.50 1.00 1.50 2.00 2.50 3.00 4.00 5.00
Evaporator Flow m³/h 0.82 0.98 1.45 1.88 2.42 2.92 3.75 4.85
water capacity 0.028 0.04 0.05 0.05 0.065 0.065 0.13 0.18
Diameter inch 1/2" 3/4" 1" 1-1/2" 1-1/2"
Condensator Type Efficient brass sets corrugated aluminum fin
Fan Type Axial flow
air volume m³/h 1000 2000 3000 4000 5000 6000 8000 10000
Protective device High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine size L mm 680 800 1040 1140 1140 1200 1400 1400
W mm 420 480 555 620 620 650 725 725
H mm 720 850 1060 1200 1200 1160 1450 1450
Unit weight Kg 60 90 130 140 170 210 270 350

 

 

Model JLSF-12HP JLSF-15HP JLSF-20HP JLSF-25HP JLSF-30HP JLSF-40HP JLSF-50HP JLSF-60HP
Cooling capacity KW/h 37.2 46.5 65 77.5 93 124 155 186
Kcal/h 29,059 37,965 50,805 61,683 74,992 97,675 116,521 156,249
Temperature range 5℃-35℃(Below 0℃ can be customized)
Power supply 1N-220V 50HZ/60HZ      3N-380V/415V 50HZ/60HZ
Total power KW 11.4 13.62 19.8 22.75 28.3 39.2 46.75 56.1
Compressor Type   Hermetic scroll type or piston
Power KW 9 11.25 15 18.75 22.5 30 37.5 45
Circulating pump Power KW 1.5 1.5 2.2 2.2 4 4 4 5.5
Head m 21.5 21.5 22 22 25 25 25 26
Refrigerant Type   R22/R407c/R134a/R410a
Control method   Temperature Sensing External Pressure Equalizing Expansion Valve
filling volume Kg 7.2 9.1 12.2 15.3 18.6 24.5 30.6 36.8
Evaporator Flow m³/h 5.81 7.6 10.16 12.34 15.2 19.53 23.3 30.52
water capacity m³/h 0.18 0.21 0.28 0.32 0.32 0.61 0.66 0.72
Diameter inch 1.5" 2" 2.5" 3"
Condensator Type   Efficient brass sets corrugated aluminum fin
Fan Type   Axial flow
air volume m³/h 12000 15000 20000 25000 30000 40000 50000 60000
Protective device High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine size L mm 1400 1750 2000 2000 2200 2000 2000 2400
W mm 725 750 900 900 900 1800 1800 1800
H mm 1450 1500 1770 1770 1770 2200 2300 2300
Unit weight Kg 370 480 590 590 880 1000 1280 1420

 


Application Industry:


Small air-cooled chillers are suitable for many different industries and applications, including but not limited to the following:

 

1.Electronics industry: Small air-cooled chillers can provide refrigeration for high-tech products such as semiconductors, optics, and electronic components to ensure the normal operation of the equipment.

 

2.Pharmaceutical industry: small air-cooled chillers can provide stable cooling effect for the link in the pharmaceutical production process that requires temperature control, ensuring the quality and safety of pharmaceuticals.

 

3.Food industry: Small air-cooled chillers can provide refrigeration for the links that require temperature control during food processing, storage and transportation to ensure the quality and safety of food.

 

4.Plastic industry: small air-cooled chillers can provide refrigeration for the temperature-controlled links in plastic injection molding, blow molding, extrusion molding, etc., to ensure product quality and production efficiency.

 

5.Chemical industry: small air-cooled chillers can provide refrigeration for the links that need temperature control in the chemical production process to ensure the quality and safety of chemical products.

 

In general, small air-cooled chillers are suitable for various occasions that require refrigeration, and provide efficient, stable and reliable refrigeration solutions for different industries.

 


  Automotive Manufacturing          Chemical Engineering              Electronics Industry                 Electroplating Industry
 

  Injection Molding Industry          Pharmaceutical Industry         Plastic Packaging Industry            Printing Industry

 

 

Upport and Services:


Air Cooled Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

 

 

Packing and Shipping:


Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

 

 

 

The importance of chillers for vacuum coating


The chiller plays a very important role in the vacuum coating process, and it has a vital impact on the quality and efficiency of vacuum coating. Specifically, the role of chillers in vacuum coating is mainly reflected in the following aspects:

 

1. Control the reaction chamber temperature: During the vacuum coating process, the temperature in the reaction chamber will continue to rise. If the temperature is too high, it will affect the quality of the film and the film forming speed. The chiller can reduce the temperature of the reaction chamber by circulating water and maintain a constant temperature in the reaction chamber to improve the quality and film forming speed of the film.

 

2. Control the temperature of the vacuum pump: The vacuum pump is an essential device in the vacuum coating process, and the increase of its temperature will reduce its pumping efficiency and life. The chiller can reduce the temperature of the vacuum pump by cooling the vacuum pump shell and the suction pipeline, improve the suction efficiency and prolong the service life of the vacuum pump.

 

3. Cooling the target: The target will generate heat during the coating process. If it is not cooled in time, it will reduce the service life of the target and affect the quality of the film. The water chiller can cool the target through circulating water, keep the constant temperature of the target, prolong the service life of the target and improve the quality of the film.

 

4. Ensure the stability of the equipment: In the process of vacuum coating, the stability of the equipment has a crucial impact on the quality and efficiency of film formation. The chiller ensures the stability of the equipment by controlling the temperature of the reaction chamber, vacuum pump and target material, so as to improve the quality and efficiency of film formation.

 

In summary, the chiller can not only ensure the stability of the equipment during the vacuum coating process, but also control the temperature of the reaction chamber, vacuum pump and target, and improve the quality and efficiency of film formation, so its importance to vacuum coating cannot be ignored .

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller

  • Year Established:

    2008

  • Total Annual:

    10 million-15 million

  • Employee Number:

    200~300

  • Ecer Certification:

    Verified Supplier

Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a... Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a...

+ Read More

Get in touch with us

  • Reach Us
  • Dongguan Jialisheng Refrigeration Equipment Co., Ltd.
  • Add: No.19,Second Street,Huangling Road,Lubian Village,Chashan Town,Dongguan,Guangdong,China.
  • https://www.waterchiller-machine.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement