Payment Terms | T/T |
Supply Ability | 300 units per month |
Delivery Time | 15 days |
Packaging Details | Plywood wooden box |
Product Name | Air Cooled Low Temperature Water Chiller |
control system | PLC/Microcomputer |
outlet water temperature | -30-35℃ |
Compressor Type | Scroll/Semi-Hermetic/Hermetic |
Evaporator | Water Tank Coil/Shell and Tube |
condenser | Finned Tube |
Condenser Fans | Axial/Centrifugal |
noise level | ≤75dB(A) |
Voltage | 220V/380V/415V/440V/480V |
Frequency | 50HZ/60HZ |
Refrigerant | R22/R407C/R134A/R410A/R404A |
protection system | High/Low Pressure, Water Flow, Overload, etc. |
Pump | Centrifugal/vertical |
Warranty | 12 months |
Brand Name | JIALIS |
Model Number | JLSFD-25HP |
Certification | CE/ISO9001 |
Place of Origin | Dongguan China |
View Detail Information
Explore similar products
JLSFD-10HP Low Temperature Chiller , Scroll Air Cooled Industrial Chiller
JLSW-40D Low Temperature Chiller , Screw Type Ethylene Glycol Chiller
JLSW-170D Low Temperature Chiller , Screw Type Glycol Water Chiller
JLSFD-20HP Low Temperature Chiller , Air Cooled Water Chillers 50HZ 60HZ
Product Specification
Payment Terms | T/T | Supply Ability | 300 units per month |
Delivery Time | 15 days | Packaging Details | Plywood wooden box |
Product Name | Air Cooled Low Temperature Water Chiller | control system | PLC/Microcomputer |
outlet water temperature | -30-35℃ | Compressor Type | Scroll/Semi-Hermetic/Hermetic |
Evaporator | Water Tank Coil/Shell and Tube | condenser | Finned Tube |
Condenser Fans | Axial/Centrifugal | noise level | ≤75dB(A) |
Voltage | 220V/380V/415V/440V/480V | Frequency | 50HZ/60HZ |
Refrigerant | R22/R407C/R134A/R410A/R404A | protection system | High/Low Pressure, Water Flow, Overload, etc. |
Pump | Centrifugal/vertical | Warranty | 12 months |
Brand Name | JIALIS | Model Number | JLSFD-25HP |
Certification | CE/ISO9001 | Place of Origin | Dongguan China |
High Light | Automatic Air Cooled Water Chiller Machine ,220V Air Cooled Water Chiller Machine ,Low Temperature Air Cooled Water Chillers |
JLSFD-25HP Air Cooled Low Temperature Water Chiller
Product Description:
Air-cooled low-temperature chiller (Air-cooled low-temperature chiller) is a device that provides low-temperature cooling through air cooling. It is commonly used in applications requiring cooling at cryogenic conditions and has some specific features and advantages.
The following are the main features of the air-cooled low temperature chiller:
1. Air cooling: The air-cooled low-temperature chiller adopts air cooling method, and transfers heat to the surrounding environment through the built-in fan and radiator. Compared with the traditional water-cooling method, it does not require additional water-cooling equipment and water sources, and is more convenient and flexible.
2. Low-temperature cooling capacity: Air-cooled low-temperature chillers can provide lower cooling temperatures, generally below -40°C. This makes it very useful in applications requiring cryogenic cooling, such as pharmaceutical, chemical, food processing and other industries.
3. Automatic control system: The air-cooled low temperature chiller is equipped with an advanced automatic control system, which can monitor and adjust the cooling temperature in real time to ensure a stable low temperature output. Users can set the required temperature range and accuracy according to their needs.
4. Energy-saving effect: The air-cooled low-temperature chiller has high energy efficiency, adopts advanced compressor and heat exchange technology, and can operate efficiently at low temperature. In addition, since no additional water cooling system is required, water resources and energy consumption of related equipment are saved.
5. Compact design: Air-cooled low-temperature chillers usually have a compact design, occupying less space, and are suitable for installation in places with limited space. They are usually self-contained units that are easy to install and maintain.
Air-cooled low-temperature chillers are widely used in industries that require low-temperature cooling, such as pharmaceutical manufacturing, laboratory research, food processing, chemical processes, etc. When selecting an air-cooled low-temperature chiller, factors such as the required cooling temperature range, power requirements, control functions, and the reliability and energy efficiency of the equipment should be considered.
Product Features:
Air-cooled chiller is a common refrigeration equipment, its main features are as follows:
1.Independence: The air-cooled chiller does not need to be connected to an external cooling water source through pipes or water pumps. It is independent and easy to install and move.
2.High efficiency and energy saving: The air-cooled chiller adopts high-efficiency compressors and heat exchangers, which can reach the set temperature requirements in a short period of time, and can also reduce energy consumption and have better energy-saving effects.
3.Easy maintenance: The air-cooled chiller is simple in structure, easy to maintain, easy to clean and repair.
4.Low noise: The air-cooled chiller has low operating noise and will not interfere with the surrounding environment and personnel. It is suitable for places that require a quiet environment.
5.Automatic control: The air-cooled chiller adopts an advanced control system, which can automatically adjust the temperature and humidity to ensure stable and reliable cooling effect.
6.Flexibility: The air-cooled chiller can be used alone or in conjunction with other equipment to meet different needs.
In general, the air-cooled chiller has the characteristics of independence, high efficiency and energy saving, easy maintenance, low noise, automatic control and flexibility, and is an ideal equipment widely used in various refrigeration needs.
Working Principle:
The main components of an air-cooled chiller include a compressor, an air condenser, an expansion valve, and an evaporator. Here is a basic overview of its workflow:
1.The compressor takes in low-pressure, low-temperature refrigerant gas and compresses it into high-pressure, high-temperature gas.
2.This high-temperature, high-pressure refrigerant gas enters the air condenser, exchanges heat with the ambient air, and discharges heat to the environment, while the refrigerant condenses from a gaseous state to a liquid state.
3.The high-pressure refrigerant liquid passes through the expansion valve, the pressure suddenly drops, and it turns into a low-pressure and low-temperature refrigerant liquid.
4.The low-temperature and low-pressure refrigerant liquid enters the evaporator, absorbs indoor heat, evaporates into a gaseous state by itself, and the indoor temperature drops to achieve the purpose of refrigeration.
5.The refrigerant gas is sucked into the compressor again to complete a cycle.
The advantages of air-cooled chillers include simple installation, no need for cooling towers and cooling water pumps, and low maintenance costs. However, its efficiency is lower than that of water-cooled chillers, especially at high ambient temperatures, and its efficiency will be further reduced
① Compressor | ⑤ Evaporator | ⑨ Temperature sensor | ⑬ Bypass valve |
② Condenser | ⑥ Ball valve | ⑩ Water tank | ⑭ Low voltage controller |
③ Filter drier | ⑦ Antifreeze switch | ⑪ Water pump pressure gauge | ⑮ High voltage controller |
④ Expansion valve | ⑧ Float switch | ⑫ Water pump | ⑯ Pressure relief valve |
Techinical Parameters:
Model | JLSFD-1HP | JLSFD-2HP | JLSFD-3HP | JLSFD-4HP | JLSFD-5HP | JLSFD-6HP | JLSFD-8HP | JLSFD-10HP | ||
Cooling capacity | KW/h | 3.1 | 6.2 | 9.3 | 12.4 | 15.5 | 18.6 | 24.8 | 31 | |
Kcal/h | 2,700 | 5,400 | 8,100 | 10,800 | 13,500 | 16,200 | 21,600 | 27,000 | ||
Temperature range | -30℃-35℃ | |||||||||
Power supply | 1PH-220V 50HZ/60HZ 3PH-380V/415V 50HZ/60HZ | |||||||||
Total power | KW | 1.21 | 2.03 | 2.84 | 3.7 | 4.5 | 5.7 | 7.33 | 8.83 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||
Power | KW | 0.75 | 1.50 | 2.25 | 3.00 | 3.75 | 4.50 | 6.00 | 7.50 | |
Circulating pump | Power | KW | 0.375 | 0.375 | 0.375 | 0.375 | 0.75 | 0.75 | 0.75 | 1.5 |
Head | m | 22 | 22 | 22 | 22 | 23 | 23 | 23 | 21.5 | |
Refrigerant | Type | R22/R407c/R134a/R410a | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 0.50 | 1.00 | 1.50 | 2.00 | 2.50 | 3.00 | 4.00 | 5.00 | |
Evaporator | Flow | m³/h | 0.82 | 0.98 | 1.45 | 1.88 | 2.42 | 2.92 | 3.75 | 4.85 |
water capacity | m³ | 0.028 | 0.04 | 0.05 | 0.05 | 0.065 | 0.065 | 0.13 | 0.18 | |
Diameter | inch | 1/2" | 3/4" | 1" | 1-1/2" | 1-1/2" | ||||
Condensator | Type | Efficient brass sets corrugated aluminum fin | ||||||||
Fan | Type | Axial flow | ||||||||
air volume | m³/h | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 680 | 800 | 1040 | 1140 | 1140 | 1200 | 1400 | 1400 |
W | mm | 420 | 480 | 555 | 620 | 620 | 650 | 725 | 725 | |
H | mm | 720 | 850 | 1060 | 1200 | 1200 | 1160 | 1450 | 1450 | |
Unit weight | Kg | 60 | 90 | 130 | 140 | 170 | 210 | 270 | 350 |
Model | JLSFD-12HP | JLSFD-15HP | JLSFD-20HP | JLSFD-25HP | JLSFD-30HP | JLSFD-40HP | JLSFD-50HP | JLSFD-60HP | ||
Cooling capacity | KW/h | 37.2 | 46.5 | 65 | 77.5 | 93 | 124 | 155 | 186 | |
Kcal/h | 29,059 | 37,965 | 50,805 | 61,683 | 74,992 | 97,675 | 116,521 | 156,249 | ||
Temperature range | -30℃-35℃ | |||||||||
Power supply | 1N-220V 50HZ/60HZ 3N-380V/415V 50HZ/60HZ | |||||||||
Total power | KW | 11.4 | 13.62 | 19.8 | 22.75 | 28.3 | 39.2 | 46.75 | 56.1 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||
Power | KW | 9 | 11.25 | 15 | 18.75 | 22.5 | 30 | 37.5 | 45 | |
Circulating pump | Power | KW | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | 4 | 5.5 |
Head | m | 21.5 | 21.5 | 22 | 22 | 25 | 25 | 25 | 26 | |
Refrigerant | Type | R22/R407c/R134a/R410a | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 7.2 | 9.1 | 12.2 | 15.3 | 18.6 | 24.5 | 30.6 | 36.8 | |
Evaporator | Flow | m³/h | 5.81 | 7.6 | 10.16 | 12.34 | 15.2 | 19.53 | 23.3 | 30.52 |
water capacity | m³/h | 0.18 | 0.21 | 0.28 | 0.32 | 0.32 | 0.61 | 0.66 | 0.72 | |
Diameter | inch | 1.5" | 2" | 2.5" | 3" | |||||
Condensator | Type | Efficient brass sets corrugated aluminum fin | ||||||||
Fan | Type | Axial flow | ||||||||
air volume | m³/h | 12000 | 15000 | 20000 | 25000 | 30000 | 40000 | 50000 | 60000 | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 1400 | 1750 | 2000 | 2000 | 2200 | 2000 | 2000 | 2400 |
W | mm | 725 | 750 | 900 | 900 | 900 | 1800 | 1800 | 1800 | |
H | mm | 1450 | 1500 | 1770 | 1770 | 1770 | 2200 | 2300 | 2300 | |
Unit weight | Kg | 370 | 480 | 590 | 590 | 880 | 1000 | 1280 | 1420 |
Application Industry:
Cryogenic chillers are widely used in many industries, some of the main application industries include:
1. Pharmaceutical and biological industry: low-temperature chillers play an important role in the fields of pharmaceuticals, biotechnology and medical equipment. They are used to control reactors, cool laboratory equipment, cryopreserve biological samples, prepare drugs and vaccines, and more.
2. Food processing industry: In the process of food processing and refrigeration, low-temperature chillers are used to control the temperature and storage conditions of food. They can be used in frozen food, refrigerated storage, fruit and vegetable preservation, beverage production, etc.
3. Industrial refrigeration industry: low-temperature chillers are widely used in the field of industrial refrigeration. For example, they can be used to cool plastic injection molding machines, metal processing equipment, semiconductor manufacturing equipment, laser cutting machines, electronic component manufacturing, and more.
4. Laboratory research industry: Many laboratories need to precisely control the temperature to meet the experimental requirements. Cryogenic chillers can be used to provide a stable low temperature environment to support research work in laboratories, such as materials science, chemistry, physics and other fields.
5. Chemical process industry: Chemical reactions usually need to be carried out under specific temperature conditions, and low-temperature chillers can provide the required low-temperature environment. Applications in the chemical process industry include synthesis reactions, solvent recovery, rectification processes, etc.
In addition, cryogenic chillers are also used in other industries, such as aerospace, electronics manufacturing, metallurgical industry, energy industry, etc. They have a wide range of applications and can meet the specific needs of different industries.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
Chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
How does the energy efficiency of air-cooled cryogenic chillers compare to water-cooled methods?
There are some differences in energy efficiency between air-cooled low-temperature chillers and water-cooled methods.
1. Heat dissipation efficiency: The water cooling method transfers heat to the cooling water through the water cooler, and then discharges the heat through the cooling water circulation system. In contrast, air-cooled low-temperature chillers dissipate heat directly to the surrounding environment through built-in fans and radiators. Due to the higher specific heat capacity of water, water cooling usually has higher heat dissipation efficiency and can remove heat more effectively.
2. Energy consumption: Since the water-cooling method requires additional water-cooling equipment and a water circulation system, in comparison, air-cooled low-temperature chillers usually have lower energy consumption. The air-cooled low-temperature chiller does not require additional water pumps and cooling water circulation systems, thus saving water energy consumption and pump energy consumption.
3. Environmental adaptability: The water cooling method requires a stable water supply and drainage system, and is suitable for areas with sufficient water resources. The air-cooled low-temperature chiller does not require water sources and drainage systems, and is suitable for various environmental conditions, especially in areas where water resources are scarce or where water-cooling equipment cannot be used.
It should be noted that the specific energy efficiency comparison is also affected by other factors, such as the design of the equipment, the efficiency of the compressor, and the design of the radiator. When choosing a chiller, comprehensive consideration should be given to the climate conditions, water resources, energy consumption requirements and actual application requirements of the equipment in the area.
On the whole, the water cooling method has advantages in terms of heat dissipation efficiency, but in terms of energy consumption and environmental adaptability, air-cooled low-temperature chillers have more advantages. Therefore, which method to choose depends on the actual situation and needs.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2008
Total Annual:
10 million-15 million
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a... Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a...
Get in touch with us
Leave a Message, we will call you back quickly!