Payment Terms | T/T |
Supply Ability | 150 units per month |
Delivery Time | 25 days |
Packaging Details | Plywood wooden box |
Product Name | Water Cooled Water Chiller |
Compressor Type | Scroll |
Evaporator | Water tank coil |
Condenser | Shell and Tube/Plate Heat Exchanger |
Control System | PLC/3 Systems Independent Control |
Controller | Microprocessor |
Noise Level | Low noise |
Power Supply | 220V/380V/415V/440V/460V/480V |
Protection Device | High/Low Pressure/Overload/Lack of Phase/Phase Sequence/Overheat |
Refrigerant | R22/R407C/R410A/R134A |
Size | Large |
Warranty | 1 Year |
Brand Name | JIALIS |
Model Number | JLSS-60HP |
Certification | CE/ISO9001 |
Place of Origin | Dongguan China |
View Detail Information
Explore similar products
JLSS-30HP PLC Industrial Water Cooled Chiller For Mold Cooling Vacuum Cooling
JLSF-20HP Air Cooled Water Chiller Frequency Conversion Constant Temperature
JLSW-60D Water Chiller Machine For Dairy Product Fermentation And Cooling
JLSW-80D Water Cooled Screw Chiller For Energy Storage Mobile Charging Stations
Product Specification
Payment Terms | T/T | Supply Ability | 150 units per month |
Delivery Time | 25 days | Packaging Details | Plywood wooden box |
Product Name | Water Cooled Water Chiller | Compressor Type | Scroll |
Evaporator | Water tank coil | Condenser | Shell and Tube/Plate Heat Exchanger |
Control System | PLC/3 Systems Independent Control | Controller | Microprocessor |
Noise Level | Low noise | Power Supply | 220V/380V/415V/440V/460V/480V |
Protection Device | High/Low Pressure/Overload/Lack of Phase/Phase Sequence/Overheat | Refrigerant | R22/R407C/R410A/R134A |
Size | Large | Warranty | 1 Year |
Brand Name | JIALIS | Model Number | JLSS-60HP |
Certification | CE/ISO9001 | Place of Origin | Dongguan China |
High Light | Large Water Cooled Industrial Chiller ,PLC Water Cooled Industrial Chiller ,Industrial large water chiller |
JLSS-60HP Water Cooled Water Chiller Space Saving, High Energy Efficiency, Precise Control,
Product Description:
Three chillers integrated machine is a device that integrates three independent chillers in one chassis or cabinet. It is designed to provide increased cooling capacity and redundancy to meet the needs of large data centers, industrial manufacturing and other large-scale applications.
Production Features:
The following are the main features and functions of the three integrated chillers:
1. High cooling capacity: By integrating three chillers together, the three chillers integrated machine can provide greater cooling capacity. This is beneficial in scenarios that require significant cooling, such as high-density server rooms or industrial manufacturing processes with high heat loads.
2. Redundant design: Three integrated chillers usually have a redundant design to ensure that when one chiller fails, the other two can continue to provide cooling capacity. This redundancy increases system reliability and stability, reducing the risk of downtime due to single points of failure.
3. Compact space utilization: Integrating three chillers in one case or cabinet can significantly save space. This is extremely valuable where space is limited or multiple chillers are required. At the same time, the integrated design also simplifies the pipeline connection and system layout, reducing the complexity of installation and maintenance.
4. Unified control system: Three integrated chillers are usually equipped with a unified control system for monitoring and controlling the entire system. Through centralized management, the operating status and parameters of each chiller can be easily monitored and adjusted to achieve coordinated operation and optimize energy efficiency.
5. Customizable configuration: Three integrated chillers can usually be customized according to customer needs. This includes cooling capacity, cooling medium, control methods and additional functions, etc. Customization to specific needs ensures optimum adaptability and performance.
Three chillers integrated all-in-one is an efficient, reliable and flexible cooling solution that can meet the cooling needs of large applications and provide redundant backup to ensure the continuity and stability of the system.
Working Principle:
The working principle of the three chillers integrated machine is as follows:
1. Refrigeration cycle: Each chiller contains a refrigeration cycle, including compressor, evaporator, condenser and expansion valve. A refrigeration cycle uses a refrigerant (usually a refrigerant fluid) to transfer heat and achieve cooling. The refrigerant undergoes a phase change during the cycle, absorbs heat from the evaporator in a low-pressure, low-temperature state, and then releases heat in a condenser in a high-pressure, high-temperature state.
2. Cooling tower: Three chillers are usually equipped with a cooling tower system. Cooling towers remove heat by spraying a cooling medium (usually water) onto the top of the tower and using air to transfer heat to the cooling medium. When the cooling medium in the cooling tower is in contact with the air, it dissipates heat through evaporation and conduction, and gradually reduces its temperature. The function of the cooling tower is to reduce the temperature of the cooling medium so that it can be circulated back to the evaporator of the chiller.
3. Water pump: Three chillers are usually equipped with a water pump system. The water pump is responsible for drawing cooling water from the cooling tower and sending it back to the chiller's evaporator. The water pump promotes the circulation of the cooling water by providing sufficient pressure and flow to ensure that the cooling water can effectively absorb heat and participate in the refrigeration cycle.
① Compressor | ⑤ Evaporator | ⑨ Temperature sensor | ⑬ Bypass valve |
② Condenser | ⑥ Ball valve | ⑩ Water tank | ⑭ Low voltage controller |
③ Filter drier | ⑦ Antifreeze switch | ⑪ Water pump pressure gauge | ⑮ High voltage controller |
④ Expansion valve | ⑧ Float switch | ⑫ Water pump | ⑯ Pressure relief valve |
Techinical Parameters:
Model | JLSS-5HP | JLSS-10HP | JLSS-15HP | JLSS-20HP | JLSS-25HP | JLSS-30HP | JLSS-40HP | JLSS-50HP | ||
Cooling capacity | KW/h | 16.2 | 32.5 | 48.7 | 64.2 | 81.2 | 97.4 | 130.3 | 163.4 | |
Kcal/h | 14,200 | 28,400 | 42,600 | 56,800 | 71,000 | 85,200 | 113,600 | 142,000 | ||
Temperature range | 5℃-35℃(Below 0℃ can be customized) | |||||||||
Power supply | 1PH-220V 50HZ/60HZ 3PH-380V/415V 50HZ/60HZ | |||||||||
Total power | KW | 4.17 | 8.25 | 12.75 | 18.2 | 20.95 | 26.5 | 35.6 | 43.2 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||
Power | KW | 3.75 | 7.5 | 11.25 | 15.0 | 18.75 | 22.5 | 30.0 | 37.5 | |
Circulating pump | Power | KW | 0.75 | 1.5 | 1.5 | 2.25 | 2.25 | 3.75 | 3.75 | 3.75 |
Head | m | 22 | 21.5 | 21.5 | 23 | 23 | 23 | 25 | 25 | |
Refrigerant | Type | R22/R407c/R134a/R410a | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 2.6 | 5.2 | 7.8 | 10.4 | 13.0 | 15.6 | 20.8 | 26.0 | |
Evaporator | Flow | m³/h | 2.75 | 5.47 | 8.62 | 11.55 | 14.03 | 17.06 | 22.19 | 26.48 |
water capacity | m³ | 0.058 | 0.150 | 0.285 | 0.300 | 0.380 | 0.380 | 0.560 | 0.560 | |
Diameter | inch | 1" | 1.5" | 2" | 2.5" | 2.5" | 3" | 3" | 3" | |
Compressor | Type | m³/h | Efficient copper shell and tube type | |||||||
Flow | m³/h | 3.42 | 6.85 | 10.78 | 14.44 | 17.54 | 21.32 | 27.74 | 33.09 | |
Diameter | inch | 1" | 1.5" | 2" | 2.5" | 2.5" | 3" | 3" | 3" | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 850 | 1300 | 1600 | 1600 | 1600 | 1800 | 2400 | 2400 |
W | mm | 480 | 610 | 700 | 730 | 730 | 760 | 1000 | 1000 | |
H | mm | 980 | 1260 | 1400 | 1500 | 1500 | 1600 | 1750 | 1750 | |
Unit weight | Kg | 60 | 150 | 400 | 440 | 690 | 760 | 850 | 1000 |
Application Industry:
Water-cooled chillers are suitable for industrial and commercial areas that require a lot of refrigeration, such as:
1.Manufacturing industry: Water-cooled chillers can be used for refrigeration of equipment and production lines in manufacturing industries such as metal processing, plastic processing, and food processing.
2.Chemical industry: Water-cooled chillers can be used for equipment and reactors that need to be cooled in the chemical production process.
3.Pharmaceutical industry: Water-cooled chillers can be used for cooling and freezing processes in the pharmaceutical industry.
4.Cold storage: Water-cooled chillers can be used in cold storage and other places that require a lot of refrigeration and keep low temperature.
5.Commercial buildings: Water-cooled chillers can be used in large commercial buildings, such as shopping malls, office buildings, hotels, etc.
6.Hospitals: Water-cooled chillers can be used in hospital operating rooms, wards and other places that need to be kept low and dry.
7.Electronics industry: Water-cooled chillers can be used for equipment cooling and temperature control in the electronics industry.
In short, water-cooled chillers are widely used in many fields, and can provide efficient, stable and reliable refrigeration services for various equipment and places.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Air Cooled Chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
What are the advantages of the integrated chiller?
The integrated chiller has the following main advantages:
1. Space saving: Integrating multiple independent chillers in one case or cabinet greatly reduces the space occupied by the equipment. This is beneficial in environments with limited space, such as machine rooms, factories or mechanical rooms within buildings. The integrated design also simplifies the arrangement of pipes and cables, making equipment installation more compact and convenient.
2. Simplified installation and maintenance: The design of the integrated chiller takes into account the convenience of installation and maintenance of the equipment. The integrated design reduces the number of plumbing connections and electrical connections, simplifying the installation process. In addition, maintenance and service work is facilitated, as all components are in one integrated unit, which is easy to access and operate.
3. High cooling capacity: Integrating multiple chillers, the integrated chiller can provide higher cooling capacity. This is important for applications that require a lot of cooling, such as large data centers, industrial manufacturing processes, or environments with high thermal loads. The integrated design of the chiller allows the system to better cope with high cooling demands, ensuring the normal operation of equipment and processes.
4. Redundant backup: The integrated chiller usually has a redundant design to ensure the reliability and stability of the system. If one of the chillers fails, the other working chillers can continue to provide cooling capacity, avoiding the risk of downtime due to a single point of failure. Redundant backups provide higher system availability and reduce potential production or service interruptions.
5. Unified control and monitoring: The integrated chiller is usually equipped with a unified control system for centralized monitoring and control of the entire system. This allows operators to easily manage and monitor the chiller's operating status, parameters and energy efficiency data. The integrated control system can also realize automatic control and optimization, and improve the operating efficiency and energy utilization of the system.
6. Flexibility and scalability: The integrated chiller usually has a modular design, which can be customized and expanded according to actual needs. Users can increase or decrease the number of chillers as needed to adapt to different cooling loads. This flexibility and scalability allows the all-in-one chiller to adapt to applications of different sizes and needs.
To sum up, the integrated chiller provides users with efficient and reliable cooling through the advantages of space saving, simplified installation and maintenance, high cooling capacity, redundant backup, unified control and monitoring, and flexibility and scalability. solution. These advantages have made the all-in-one chiller a common choice for cooling equipment in large-scale applications and critical facilities.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2008
Total Annual:
10 million-15 million
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a... Dongguan Jialisheng Refrigeration Equipment Co., Ltd. is a modern enterprise focusing on the research, development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. With a...
Get in touch with us
Leave a Message, we will call you back quickly!