Payment Terms | T/T |
Packaging Details | carton packing/wooden box package |
Explosive Gas Atmosphere | Zone 1,Zone 2,IIA,IIB |
Applied to temperature | group T1-T6 |
Brand Name | Warom |
Model Number | BXCQ |
Place of Origin | China |
View Detail Information
Explore similar products
Product Specification
Payment Terms | T/T | Packaging Details | carton packing/wooden box package |
Explosive Gas Atmosphere | Zone 1,Zone 2,IIA,IIB | Applied to temperature | group T1-T6 |
Brand Name | Warom | Model Number | BXCQ |
Place of Origin | China | ||
High Light | flameproof overflow static grounding control system ,explosion proof overflow static grounding control system |
Performance Features
◆ The controller enclosure is flameproof type, reliable explosion-proof performance.
◆ Static grounding clamp has tank car identification function, ensure its installed on tank car correctly, not other electric conductor, with no-spark type grounding clamp, no spark produced when equipment impact.
◆ Static grounding clamp has resistance inspection and liquid level monitoring function, provide local and remote audible and visual alarm and interlocking signal for “static” and ''overflow status”, which is convenient for operator to find out problem and avoid overflow accident.
◆ Grounding body resistance has inspection function, ensure reliable grounding of system, when electrostatic grounding is bad or grounding loop resistance >10Ω, provide alarm warning.
◆ With voice and LCD function, the intensity of the sound is 70~120db (the distance is 30cm).
◆ Relay signal output for DCS pump (valve), when grounding is not normal, cut off the operation, audible and visual alarm can still be remote controlled, remind operator the real-time status of on-site grounding.
◆ Red LED shows warning, green LED shows normal working, yellow LED shows standby status.
◆ Grounding clamp uses alloy aiding thimble, with the features of high hardness, good electric conduction, strong breaking paint and rust power, etc. ensure good grounding monitoring device.
◆ Grounding clamp is helix tube shrink design, with the capacities of strength anti-pull, anti-drop, etc.
◆ It can intelligently detect whether the human static voltage is conducted, when the human static voltage is in a dangerous value,sound and light alarm.
Type spec. and name | Parameters | Remark |
BXCQ-YJC Explosion-proof Overflow Static Grounding Controller | Ex mark: Protection degree: IP66 Response time: <1S Test resistance: <10Ω Working voltage: 100~250V AC 50/60HZ, Working current: <20mA Warning method: Interlocking signal and three color light instruction Output signal: Relay output, NO NC is optional, 10A 30VDC or 10A 250VAC Enclosure size: 200x300x170 mm Installation dimension: 210x230 mm | Aluminium alloy enclosure |
BXCQ-JC Explosion-proof StaticGrounding Controller | Ex mark: Protection degree: IP66 Response time: <1S Test resistance: <10Ω Working voltage: 100~250V AC 50/60HZ, Working current: <20mA Warning method: sound and light alarm (optional) Output signal: Relay output, NO NC is optional, 10A 30VDC or 10A 250VAC Enclosure size: 200x300x170 mm Installation dimension: 210x230 mm | Aluminium alloy enclosure |
BXCQ-YC Explosion-proof Overflow Controller | Ex mark: Protection degree: IP66 Response time: <1S Working voltage: 100~250V AC 50/60HZ, Working current: <20mA Warning method: Interlocking signal and three color light instruction Output signal: Relay output, NO NC is optional 10A 30VDC or 10A 250VAC Enclosure size: 200x300x170 mm Installation dimension: 210x230 mm | Aluminium alloy enclosure |
BXCQ-JCL Explosion-proof Static Grounding Controller (dual purposes of manand motor) | Ex mark: Protection degree: IP66 Response time: <1S Test resistance: <10Ω Working voltage: 220VAC or 24VDC Working current: <20mA Warning method: sound and light alarm (optional) Output signal: Relay output, NO NC is optional, 10A 30VDC or 10A 250VAC Touching ball material: Electrostatic subconductor Touching ball diameter: 90mm Enclosure size: 200x300x170 mm Installation dimension: 210x230 mm | Aluminium alloy enclosure |
BXJ-IIB Series Explosion-proof Junction Box | Ex mark: Protection degree: IP66 | Aluminium alloy enclosure |
Static Grounding Clamp | Clamp tooth material: Tungsten alloy Opening range:Clamp body material: 304 (316 optional) | |
Corrosion Resistance Helical Line | Cable material: Copper wire Surface material: PU Standard equipment length: 7m | The length of helical Line is customized, the max length is 15m |
Homing board | Material: 304 stainless steel |
BXCQ Explosion-proof Overflow Static Grounding Control System
(Download here:BXCQ Explosion-proof Overflow Static Grounding Control System.pdf)
Contact us for more information:
Address : No. 555, Baoqian Road, Jiading District, Shanghai, China
Zip Code: 201808
Tel: +86 21 39977076 /+86 21 39972657
Fax: +86 21 39977077
E-mail: gmb@warom.com
Company Details
Business Type:
Manufacturer,Seller
Year Established:
1987
Total Annual:
1000000-2000000
Employee Number:
2000~2300
Ecer Certification:
Verified Supplier
Warom Technology Incorporated Company(The former name is WAROM Group Co., Ltd.)IPO Company , founded in 1987. It is a diversified enterprise with explosion-proof industry as its leader, integrating product research anddevelopment, manufacturing and sales. Located in Ji... Warom Technology Incorporated Company(The former name is WAROM Group Co., Ltd.)IPO Company , founded in 1987. It is a diversified enterprise with explosion-proof industry as its leader, integrating product research anddevelopment, manufacturing and sales. Located in Ji...
Get in touch with us
Leave a Message, we will call you back quickly!