Payment Terms | L/C, T/T, Western Union |
Supply Ability | 10000pcs/month |
Packaging Details | Factory Standard |
Conncet Pipe | 100% Copper Pipe |
Compressor | GMCC/Gree |
Fan Motor | Welling |
Panel | UA Design |
Power | 220V/50hz |
Frequency | 50hz |
Brand Name | Yuetu or OEM |
Model Number | 12000Btu |
Certification | CE/CB |
Place of Origin | CHINA |
View Detail Information
Explore similar products
12k R410a 12000btu Wall Mounted Inverter Air Conditioner 50hz 220v
50hz 220V 9000Btu Wall Inverter Air Conditioner For Bedroom House
R410A Wall Inverter Air Conditioner 9000 Btu 60hz 220V Wifi Control
UA Panel 9000BTU Wall Mounted Air Cooler 220V R410a R32 Split AC
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 10000pcs/month |
Packaging Details | Factory Standard | Conncet Pipe | 100% Copper Pipe |
Compressor | GMCC/Gree | Fan Motor | Welling |
Panel | UA Design | Power | 220V/50hz |
Frequency | 50hz | Brand Name | Yuetu or OEM |
Model Number | 12000Btu | Certification | CE/CB |
Place of Origin | CHINA | ||
High Light | 12K 2600W Cooling Heating Air Conditioner ,50hz Cooling Heating Air Conditioner ,12K 2600W cool heat air conditioner |
50hz 220V Cooling Heating Air Conditioner Wall Mounted 12000BTU
UA Panel Inverter 220V R410a/R32 12000BTU Cooling Heating High Quality WifiControl PCB3 Year Warranty Split AC GMCC/GREE
- To adjust the temperature during sleep, the air conditioner can automatically adjust the sleep temperature
- The outdoor unit must be installed firmly to reduce vibration and noise. There must be enough space in front of the suction and exhaust vents of the condenser for ventilation. If the wind is blocked, the condensation pressure will increase and it will cause shutdown;
- There should be no obstacles in front of the indoor unit, otherwise the wind will be affected;
When the air conditioner is running for rapid cooling, the selector switch can be adjusted to the high gear, and after the temperature drops, it can be adjusted to the medium-speed low gear;
INVTER | 12K | ||
825X(φ7×1)+700φ7×1) | |||
Type | Cooling only | ||
Control type | remote | ||
Rated cooling capacity | Btu/h | 8871 | |
W | 2600 | ||
Rated heating capacity | Btu/h | / | |
W | / | ||
EER for cooling | W/W | 3.2 | |
COP for heating | W/W | / | |
Moisture removal | Liters/h | 1 | |
Pressure | High(DP) | MPa | 4.5 |
Low(SP) | MPa | 1.9 | |
Indoor noise level at cooling | SUPER | dB(A) | / |
High | dB(A) | 41 | |
Med | dB(A) | 39 | |
Low | dB(A) | 37 | |
MUTE | dB(A) | / | |
Outdoor noise level | dB(A) | 51 | |
Electrical Data | |||
Power supply | 220-240V/50Hz | ||
Voltage Range | V | 187~264 | |
Rated current | Cooling | A | 5.3 |
Heating | A | / | |
Rated input | Cooling | W | 1175 |
Heating | W | / | |
Max Current | Cooling | A | 13 |
Heating | A | / | |
Max Power input | Cooling | W | 2750 |
Heating | W | / | |
Refrigerating System | |||
Refrigerant/Charge | Gram | R410A/420g | |
Compressor | Model | KSK103D53UFZ | |
MFG | GMCC | ||
Type | Rotary | ||
Connections | |||
Connecting Pipe | Gas | Inches | Φ9.52(3/8'') |
Liquid | Inches | Φ6(1/4'') | |
Connecting Wiring | Size x Core number | 1.5*5 | |
Drainage Pipe | O.D 16mm | ||
Others | |||
Suitable area | m2 | ||
Net dimensions (W x H x D) | Indoor | mm | 825*290*195 |
Outdoor | mm | 700*540*255 | |
Net weight | Indoor | kg | 9 |
Outdoor | kg | 31 | |
Packing dimensions (W x H x D) | Indoor | mm | 885×359×276 |
Outdoor | mm | 815×350×600 | |
Gross weight) | Indoor | kg | 8.5 |
Outdoor | kg | 27 |
- The indoor temperature cannot be adjusted too low, otherwise it is harmful to the human body, so the set temperature should be adjusted appropriately.
- If you feel the room temperature is too high, you can appropriately lower the set temperature.
Effective use of timers can achieve both energy-saving and comfortable effects.
- There should not be too many people or overcrowding in the air-conditioned room, otherwise the cooling capacity will be insufficient and the temperature will not drop;
- Doors and windows of the room should not be opened and closed frequently, and personnel should not enter and exit frequently to avoid loss of air-conditioning;
- The glass windows must be closed and tightly closed, and double white curtains must be hung inside to reflect part of the light and heat that penetrates;
- The window can be opened for a short time during indoor ventilation, and the window opening time is generally no more than 10 minutes
- The air filter should be cleaned regularly, otherwise the air flow will be blocked, resulting in insufficient air volume and increased room temperature
Company Details
Business Type:
Manufacturer
Year Established:
2015
Total Annual:
8000000-10000000
Employee Number:
500~700
Ecer Certification:
Active Member
In 2015, Yuetu moved to Ninghua from Wenzhou, and covering an area with 300,000 square meter. There are total 12 production lines with 3 million sets production capacity annually and 95% of the parts self produced, such as heat exchanger, welding, bending, automatic coating, plastic injection, and s... In 2015, Yuetu moved to Ninghua from Wenzhou, and covering an area with 300,000 square meter. There are total 12 production lines with 3 million sets production capacity annually and 95% of the parts self produced, such as heat exchanger, welding, bending, automatic coating, plastic injection, and s...
Get in touch with us
Leave a Message, we will call you back quickly!