Payment Terms | L/C, , T/T |
Supply Ability | 100000pcs/month |
Delivery Time | 45 days after receipt of the deposit |
Packaging Details | Standard export carton box package suitable for container shipment. |
Conncet Pipe | 100% Copper Pipe |
compressor | GREE/GMCC |
Type | Wall Mounted |
Use | living Room |
Name | Inverter Wall Air Conditioner |
Capacity (btu) | 12000Btu |
Brand Name | YUETU or OEM |
Model Number | 12000BTU |
Certification | CE/BC |
Place of Origin | CHINA |
View Detail Information
Explore similar products
12k R410a 12000btu Wall Mounted Inverter Air Conditioner 50hz 220v
50hz 220V 9000Btu Wall Inverter Air Conditioner For Bedroom House
50hz 220V Cooling Heating Air Conditioner Wall Mounted 12000BTU
R410A Wall Inverter Air Conditioner 9000 Btu 60hz 220V Wifi Control
Product Specification
Payment Terms | L/C, , T/T | Supply Ability | 100000pcs/month |
Delivery Time | 45 days after receipt of the deposit | Packaging Details | Standard export carton box package suitable for container shipment. |
Conncet Pipe | 100% Copper Pipe | compressor | GREE/GMCC |
Type | Wall Mounted | Use | living Room |
Name | Inverter Wall Air Conditioner | Capacity (btu) | 12000Btu |
Brand Name | YUETU or OEM | Model Number | 12000BTU |
Certification | CE/BC | Place of Origin | CHINA |
High Light | 4300W Inverter Wall Air Conditioner ,60hz Inverter Wall Air Conditioner ,4300W 12000Btu Wall Air Conditioner |
60hz 220V Inverter Wall Air Conditioner 12000Btu Wifi Control PCB
YC Panel R410a Wall Inverter Air Conditioner 60hz 220V 12000Btu Cooling Heating Pump Wifi Control PCB 3 Year Warranty
Precautions
- The indoor temperature cannot be adjusted too low, otherwise it is harmful to the human body, so the set temperature should be adjusted appropriately.
- If you feel the room temperature is too high, you can appropriately lower the set temperature.
Effective use of timers can achieve both energy-saving and comfortable effects.
- There should not be too many people or overcrowding in the air-conditioned room, otherwise the cooling capacity will be insufficient and the temperature will not drop;
Technical Specifications | |||
INVTER | 12K | ||
825X(φ7×1)+700φ7×1) | |||
Type | heating pump | ||
Control type | remote | ||
Rated cooling capacity | Btu/h | 11942 | |
W | 3500 | ||
Rated heating capacity | Btu/h | 14672 | |
W | 4300 | ||
EER for cooling | W/W | 2.6 | |
COP for heating | W/W | / | |
Moisture removal | Liters/h | 1.0 | |
Pressure | High(DP) | MPa | 4.2 |
Low(SP) | MPa | 1.5 | |
Indoor noise level at cooling | SUPER | dB(A) | / |
High | dB(A) | 41 | |
Med | dB(A) | 37 | |
Low | dB(A) | 21 | |
MUTE | dB(A) | / | |
Outdoor noise level | dB(A) | 51 | |
Electrical Data | |||
Power supply | 220-240V/60Hz | ||
Voltage Range | V | 187~264 | |
Rated current | Cooling | A | 4.6 |
Heating | A | 5.5 | |
Rated input | Cooling | W | 1045 |
Heating | W | 1100 | |
Max Current | Cooling | A | 13 |
Heating | A | 13 | |
Max Power input | Cooling | W | 2750 |
Heating | W | 2850 | |
Refrigerating System | |||
Refrigerant/Charge | Gram | R410A | |
Compressor | Model | / | |
MFG | / | ||
Type | Rotary | ||
Connections | |||
Connecting Pipe | Gas | Inches | Φ12(1/2'') |
Liquid | Inches | Φ6(1/4'') | |
Connecting Wiring | Size x Core number | 1.5*5 | |
Drainage Pipe | O.D 16mm | ||
Others | |||
Suitable area | m2 | 12~23 | |
Net dimensions (W x H x D) | Indoor | mm | 825*290*195 |
Outdoor | mm | 700*540*255 | |
Net weight | Indoor | kg | 9 |
Outdoor | kg | 31 | |
Packing dimensions (W x H x D) | Indoor | mm | 885*359*276 |
Outdoor | mm | 815×350×600 | |
Gross weight) | Indoor | kg | 8.5 |
Outdoor | kg | 27 | |
- The outdoor unit must be installed firmly to reduce vibration and noise. There must be enough space in front of the suction and exhaust vents of the condenser for ventilation. If the wind is blocked, the condensation pressure will increase and it will cause shutdown;
- There should be no obstacles in front of the indoor unit, otherwise the wind will be affected;
When the air conditioner is running for rapid cooling, the selector switch can be adjusted to the high gear, and after the temperature drops, it can be adjusted to the medium-speed low gear;
- The ventilation switch can be used for the ventilation of the window air conditioner, but the ventilation time should not exceed 15 minutes;
- The outdoor unit of split type air conditioner cannot be inserted with sticks, otherwise the fan will be stuck or damaged
- After the air conditioner is stopped, it must be restarted after three minutes to protect the compressor;
how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF;
Accepted Payment Currency: USD, EUR;
Accepted Payment Type: T/T,L/C;
How to place an order?
A: Please choose the models,designs,and shipping way you want,and place an order on the link which you are looking for.Then finish the payment steps by alibaba. Any problems pls leave us a message.
Company Details
Business Type:
Manufacturer
Year Established:
2015
Total Annual:
8000000-10000000
Employee Number:
500~700
Ecer Certification:
Active Member
In 2015, Yuetu moved to Ninghua from Wenzhou, and covering an area with 300,000 square meter. There are total 12 production lines with 3 million sets production capacity annually and 95% of the parts self produced, such as heat exchanger, welding, bending, automatic coating, plastic injection, and s... In 2015, Yuetu moved to Ninghua from Wenzhou, and covering an area with 300,000 square meter. There are total 12 production lines with 3 million sets production capacity annually and 95% of the parts self produced, such as heat exchanger, welding, bending, automatic coating, plastic injection, and s...
Get in touch with us
Leave a Message, we will call you back quickly!