Payment Terms | L/C, T/T, Western Union,Paypal |
Supply Ability | 20000Pcs per month |
Delivery Time | 1-30 days upon order quantity |
Packaging Details | Voltage relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable. |
Type | JVR1000 |
Rated Voltage | AC380V |
Phase sequence tripping time | instant |
Phase loss tripping time | 1s |
Hysteresis | 10V |
Delay time for overvoltage and undervoltage | 0.1-25s adjustable |
Brand Name | GINRI |
Model Number | JVR1000 |
Certification | CE,CCC |
Place of Origin | China |
View Detail Information
Explore similar products
Pumps Three Phase Voltage Monitoring Relay , JVM-A Phase Detection Relay 460VAC
Phase sequence Three Phase Voltage Monitoring Relay Miniature voltage relay
Digital Three Phase Voltage Monitoring Relay Over voltage protector AC380V 6A
Elevator part Three Phase Voltage Monitoring Relay phase failure protective
Product Specification
Payment Terms | L/C, T/T, Western Union,Paypal | Supply Ability | 20000Pcs per month |
Delivery Time | 1-30 days upon order quantity | Packaging Details | Voltage relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable. |
Type | JVR1000 | Rated Voltage | AC380V |
Phase sequence tripping time | instant | Phase loss tripping time | 1s |
Hysteresis | 10V | Delay time for overvoltage and undervoltage | 0.1-25s adjustable |
Brand Name | GINRI | Model Number | JVR1000 |
Certification | CE,CCC | Place of Origin | China |
High Light | 3 phase undervoltage relay , 3 phase monitoring relay |
Compressors Used Three Phase Voltage Monitoring Relay 1-25s time delay protector
All electric appliances are very sensitive when using the grid voltage is too high too low, whether industrial equipment or household appliances have a rated voltage, the voltage range is usually specified as 170V-240V (can be seen on the nameplate or instructions of the electrical equipment). If this voltage is exceeded, the insulation strength and pressure resistance of the electric appliance are exceeded, and the electric appliance will thus generate heat, breakdown and burn or even cause a fire. At present, due to the theft of the zero line, aging equipment, technical failures, human failures, natural disasters, power outages, and other reasons, the voltage instability, the voltage is too low, resulting in a large number of electrical appliances are burned out and burned in large areas, People have suffered heavy losses, no claims, and labor and people’s misfortune have come one after another. Yimin’s overpressure, overpressure, and undervoltage protectors (also known as electrical protectors) should be added to prevent electrical fires and protect the safety of lives and property.
The state provides that the single-phase 220V power supply error shall not be greater than or equal to 10% of 220V, that is, when 220V is over 242V, it is called overvoltage; below 198V, it is called undervoltage. In the single-phase 220V power supply, 220V suddenly rises to 380V or 440V ultra high voltage, which is called overvoltage; when the grid voltage suddenly changes overvoltage, overvoltage and undervoltage, the device that can automatically cut off the power quickly and intelligently is called overvoltage. Overvoltage and undervoltage protectors.
♦ Features
-- Built-in LCD and keypad afford a precise,digital setting-- Three-phase monitoring of phase sequence, phase loss, over- and undervoltage and phase unbalance-- Adjustable over- and undervoltage, phase unbalance threshold-- Independent adjustable delay time for overvoltage, undervoltage, phase unbalance-- Powered by the measuring circuit-- 1 NO & 1NC contacts-- Faulure recording
♦ Protective Functions
-- Phase sequence-- Phase loss-- Phase unbalance-- Overvoltage-- Undervoltage
♦ Typical Applications
• Pumps • Fans• Blowers • Motors• Compressors
♦ Approvals
• CE • CCC
♦ Technical data
Type | JVR1000 |
Measuring circuit | L1,L2,L3 |
Rated voltage | 380VAC ,50Hz |
Monitoring functions | phase sequence, phase loss, overvolatege, undervoltage,phase unbalance |
Overvoltage setting range | 390-490V adjustable |
Undervoltage setting range | 300-470V adjustable |
Hysteresis | 10V |
Delay time for overvoltage and undervoltage | 0.1-25s adjustable |
Phase unbalance setting range | 5%-29% adjustable |
Delay time for phase unbalance | 1-25s adjustable |
Delay time for phase loss | 1s |
Delay time for phase sequence | instant |
Indicators | LCD indicating voltage,current,operation status |
Output contacts | 1 NO,1NC |
Contact capacity | 6A ,250VAC |
Dimensions (H x W x D) | 80×40×54mm |
Mounting | DIN rail |
Company Details
Business Type:
Manufacturer
Year Established:
1995
Employee Number:
50~100
Ecer Certification:
Active Member
GINRI POWER AUTOMATION CO.,LTD. is a professional production voltage phase sequence protection device (and name: three-phase power monitor), and PLC output zoom Board, and smart type motor integrated protection device, and industrial parts manufacturers, technology development team in elevator indus... GINRI POWER AUTOMATION CO.,LTD. is a professional production voltage phase sequence protection device (and name: three-phase power monitor), and PLC output zoom Board, and smart type motor integrated protection device, and industrial parts manufacturers, technology development team in elevator indus...