China factories

China factory - Wenzhou Ginri Power Automation Co., Ltd.

Wenzhou Ginri Power Automation Co., Ltd.

  • China ,Zhejiang
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Overload Current Monitoring Relay 1 NC SCR Output Contact LED Indication
China Overload Current Monitoring Relay 1 NC SCR Output Contact LED Indication

  1. China Overload Current Monitoring Relay 1 NC SCR Output Contact LED Indication
  2. China Overload Current Monitoring Relay 1 NC SCR Output Contact LED Indication

Overload Current Monitoring Relay 1 NC SCR Output Contact LED Indication

  1. MOQ: 20Pcs
  2. Price:
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union,Paypal
Supply Ability 20000Pcs per month
Delivery Time 1-30 days upon order quantity
Packaging Details Voltage relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable
Monitoring Function overcurrent, phase loss, current unbalance
Features Powered by measuring circuit
Indicators 4 LEDS
Output Contact 1NC SCR
Contact Capacity 1A 380VAC
Guarantee 18 months
Brand Name GINRI
Model Number JDB-1
Certification CE,CCC
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union,Paypal Supply Ability 20000Pcs per month
Delivery Time 1-30 days upon order quantity Packaging Details Voltage relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable
Monitoring Function overcurrent, phase loss, current unbalance Features Powered by measuring circuit
Indicators 4 LEDS Output Contact 1NC SCR
Contact Capacity 1A 380VAC Guarantee 18 months
Brand Name GINRI Model Number JDB-1
Certification CE,CCC Place of Origin CHINA
High Light current control relay motor current monitoring relay

Overload Current Monitoring Relay 1 NC SCR Output Contact LED Indication
 
JDB-1 series motor protector is suitable for the control circuit of AC 45 ~ 60Hz, voltage 24V to 380V power supply circuit and AC contactor and other switch electrical appliances. When the main circuit of the motor has abnormal working conditions such as phase failure, overload, and three-phase unbalance, the protector can break the contact of the switch electrical appliance in time, disconnect the three-phase power supply of the motor, and quickly and reliably protect the motor.
The protector adopts the core-type current sampling detection technology, thyristor output, simple structure, convenient use, reliable operation, and has the advantages of no power consumption, long life, no arc generation during operation, and is ideal for motor protection. Electrical products
The protector meets the requirements of EN19474.7, EN60947-5, EN60204-1 standard GB14048.4.
 
(1) Protection functions: Phase protection, three-phase unbalance protection, and overload protection.
1. Phase-failure protection: When any phase of the three-phase power supply of the motor lacks a phase or the internal phase of the motor is broken, the action delay time of the protector is ≤ 1S.
2. Three-phase unbalance protection: When the phase difference of any two-phase working current in the three-phase power supply of the motor exceeds (50±10)%, the delay time of the protector operation is ≤1S.
3. Overload protection: When the operating current of the motor reaches 1.2 times to 6 times of the rated value, the action delay time of the protector is 80S ~ 10S (inverse time characteristic).
(B), the output interface reset mode: control circuit power reset; reset time: (60 ± 10) S.
(C), work methods: continuous work style.
(D), applicable voltage range: AC24V ~ 380V/45 ~ 60Hz.
 
♦ Features
Integrative structure Three-phase monitoring of overload, phase loss, phase unbalance Powered by the measuring circuit 1 NC SCR output contact  4 LEDs for status indication
 
♦ Protective Functions
Overload,Phase loss,Phase unbalance
 
♦ Typical Applications
 Pumps . Fans, Blowers , Motors, Compressors
 
 
♦ Approvals
CE • CCC
 
♦ Technical data
 

Type JDB-1
Current range

2.5-5A,4-10A,8-20A,16-40A,32-80A,
63-160A,150-300A

Startup delay 5s,10s,20s
Protective functions overload,phase loss,phase unbalance
Setting method by knob
Indicators ABC overload&phase loss
Output contacts 1NC(SCR output)
Contact capacity 1A 380VAC
Operating voltage of control loop AC220V or AC380V
Dimensions(H*W*D)

2.5-40A:38*90*63mm
80-300A:44.5*123*67mm

Mounting screw fixing


 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    1995

  • Employee Number:

    50~100

  • Ecer Certification:

    Active Member

GINRI POWER AUTOMATION CO.,LTD. is a professional production voltage phase sequence protection device (and name: three-phase power monitor), and PLC output zoom Board, and smart type motor integrated protection device, and industrial parts manufacturers, technology development team in elevator indus... GINRI POWER AUTOMATION CO.,LTD. is a professional production voltage phase sequence protection device (and name: three-phase power monitor), and PLC output zoom Board, and smart type motor integrated protection device, and industrial parts manufacturers, technology development team in elevator indus...

+ Read More

Get in touch with us

  • Reach Us
  • Wenzhou Ginri Power Automation Co., Ltd.
  • No.337,Kaichuang Road,Baitawang Industrial Distrit, Beibaixiang Town,Yueqing City,Zhejiang Province,China
  • https://www.voltagemonitoringrelay.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement