China factories

China factory - Jinan Should Shine Didactic Equipment Co., Ltd.

Jinan Should Shine Didactic Equipment Co., Ltd.

  • China,Jinan ,Shandong
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Fire Alarm Didactic Building Automation Trainer Training Kit Teaching Model
China Fire Alarm Didactic Building Automation Trainer Training Kit Teaching Model

  1. China Fire Alarm Didactic Building Automation Trainer Training Kit Teaching Model

Fire Alarm Didactic Building Automation Trainer Training Kit Teaching Model

  1. MOQ: 1 set
  2. Price: Negociate
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, Western Union, T/T
Supply Ability 5000 sets per year
Delivery Time 35 days
Packaging Details plastic film+carton+plywood box
Model ZM5125A
Application building automation trainer for colleges, university
Dimension 3.59CBM
Weight 398kgs
Function educational and teaching for colleges
package plywood
Brand Name ShouldShine
Model Number ZM5125A
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, Western Union, T/T Supply Ability 5000 sets per year
Delivery Time 35 days Packaging Details plastic film+carton+plywood box
Model ZM5125A Application building automation trainer for colleges, university
Dimension 3.59CBM Weight 398kgs
Function educational and teaching for colleges package plywood
Brand Name ShouldShine Model Number ZM5125A
Certification ISO9001 Place of Origin China
High Light building automation trainerbuilding automation trainer

ZM5125A Fire Alarm Didactic Bench Building Automation Training Kit Teaching Model

I. Training purpose


This experimental training device enables students to do fire alarm system components, function, composition and principles understanding training.


The experimental training device enables students to do fire and alarm linkage simulating operation, the fire-alarm controller panel indicators and buttons function operation, fire-alarm controller state understanding operation, fire-alarm controller basic functions, time modifying operation, password modifying operation, different passwords permissions operation, communication management operation, the machine self-test operation, print management operation, system initialization operation, the total number querying operation, the machine information operating, event recording and querying operation, fire alarm records querying operation, equipment start-stop operating, loop editing by group , single-point loop editing, shielding open operation, automatic login operation, linkage programming operation, sound and light linkage setting operation, networking with CRT fire monitoring center operation, networking with fire radio telephone system experimental training device operation, networking with automatic sprinkler extingiushment system experimental training device operation, component structure identifying and installing, connect the various parts according to the circuit diagram, design and install a simple application system .


The experimental training device enables students to judge and deal with line faults, judge and correct programming setting error.


2. Technical specification


Working voltage: single phase three wire 220V±5%50Hz
Whole machine capacity: <200W
Boundary dimension: 150×70×180cm3
Safety protection: it is equipped with electric leakage automatic protection device and ground protection.
Fault setting: fault setting module can carry out controller setting and the fault setting and shooting of hardware circuit.


3.Training project


Training one: the understanding training of Fire Detection Linked System component , function, content and principle
Training two: fire and alarm linked simulation operation training
Training three:the operation training of indicator light and button function on the fire control mainframe board
Training four: the understanding operation training of fire control mainframe state.
Training five: fire control mainframe basic function operation training
Training six: modification time operation training
Training seven: modification password operation training
Training eight: the training operation of different password jurisdiction
Training nine: communication management operation training
Training ten: local machine self-inspection operation training
Training eleven: the operation training of print management
Training twelve: the operation training of system initialization
Training thirteen: total number inquire operation training
Training fourteen: local machine information operation training
Training fifteen: incident record inquire operation training
Training sixteen: fire alarm record inquire operation training
Training seventeen : machine start and stop operation training
Training eighteen: editing operation training according to group circuit
Training nineteen: single point circuit editing operation training
Training twenty: shield opening operation training
Training twenty-one: automatic login operation training
Training twenty-two: linked editing operation training
Training twenty-three: acousto-optic linked setting operation training
Training twenty-four: the networking operation training of CRT fire control monitoring center.
Training twenty-five: the networking operation training of fire control broadcast phone system experiment device.
Training twenty-six: the networking operation training of automatic sprinkler fire extinguishing system experiment device
Training twenty-seven: the structure understanding and installation training of component
Training twenty-eight: he judgment and treatment operation training of wiring fault
Training twenty-nine: the judgment and rectification training of programme setting error
Training thirty-: each portion wiring training according to circuit diagram
Training thirty-one : design and install a simple application system

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company,Seller

  • Year Established:

    2012

  • Total Annual:

    3000000-5000000

  • Employee Number:

    120~150

  • Ecer Certification:

    Active Member

Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Fluid Lab Equipment, air conditioner trainer, refrigeration trainer, Thermal Lab Equipment, Vocational Training Equipment, Didactic Equipment, Engineering Educational Equipment, Technical Teaching Equip... Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Fluid Lab Equipment, air conditioner trainer, refrigeration trainer, Thermal Lab Equipment, Vocational Training Equipment, Didactic Equipment, Engineering Educational Equipment, Technical Teaching Equip...

+ Read More

Get in touch with us

  • Reach Us
  • Jinan Should Shine Didactic Equipment Co., Ltd.
  • No.15126 Century Avenue, Room 1-1612, Building 1, High Tech Zone,Jinan,China
  • https://www.vocationaleducationequipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement