China factories

China factory - Jinan Should Shine Didactic Equipment Co., Ltd.

Jinan Should Shine Didactic Equipment Co., Ltd.

  • China,Jinan ,Shandong
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Educational Heat Transfer Lab Equipment Wet Cooling Tower ISO9001
China Educational Heat Transfer Lab Equipment Wet Cooling Tower ISO9001

  1. China Educational Heat Transfer Lab Equipment Wet Cooling Tower ISO9001

Educational Heat Transfer Lab Equipment Wet Cooling Tower ISO9001

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms L/C, T/T, D/A, D/P, Western Union
Supply Ability 500 SET YEAR
Delivery Time 30
Packaging Details Fine Plywood Box
Product name Wet Cooling Tower
Usage Heat Transfer Lab Equipment
Package Fine Plywood Box
Warranty 2 years
Brand Name SSEDU
Model Number ZT0022
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, D/A, D/P, Western Union Supply Ability 500 SET YEAR
Delivery Time 30 Packaging Details Fine Plywood Box
Product name Wet Cooling Tower Usage Heat Transfer Lab Equipment
Package Fine Plywood Box Warranty 2 years
Brand Name SSEDU Model Number ZT0022
Certification ISO9001 Place of Origin China
High Light Educational Heat Transfer Lab EquipmentWet Cooling Tower Heat Transfer EquipmentsWet Ventilation Heat Transfer Equipments

ZT0022 Wet Cooling Tower Educational Equipment Heat Transfer Lab Equipment
 

I. Product content

1 Product overview

1.1 Overview

The ZT 0022 countercurrent wet ventilation cooling tower experimental platform is a training device used by the laboratory to verify the principle of forced convection heat transfer in the cooling tower. During the experiment, the water in the circulation loop is sprayed on the tower packing through the atomization spray device. Fans are arranged under the tower to realize forced convection heat exchange. During the process, part of the heat is transferred from water to the air, and the water temperature, air temperature, air humidity, air flow, water flow, etc. are recorded through the meter in the circulation of the experimental platform. The data achieves the purpose of experimental analysis. The data can be directly displayed on the display screens of the console, or transmitted to the PC through a USB device for further processing.

1.2 Features

The water flow and air flow in the working cycle of the experimental bench can be adjusted;

The data of each point of the workbench cycle can be digitally displayed by instruments (including water temperature, air temperature, water flow, air flow);

The data of each point of the workbench cycle can be displayed on the PC through a USB device;

According to the needs of the design experiment, the workbench is equipped with a replaceable cooling tower body for comparison research;

2 Preview Content

2.1 The main factors affecting heat and moisture transfer

In a cooling tower under normal operation, the main factors that affect the heat transfer process of the cooling tower are the inlet air wet bulb temperature (absolute saturation temperature), inlet water temperature, air volume, and circulating water volume. These four factors, of which water volume and air volume The ratio of is called the water-to-air ratio.

The influence of the inlet air wet bulb temperature:

Control other influencing factors unchanged (inlet water temperature, water volume, air volume), the heat transfer power (enthalpy difference) of the entire heat transfer process decreases with the increase of outdoor air wet bulb temperature, which means that the cooling tower's heat dissipation capacity is worse .

The influence of inlet water temperature:

Control other factors unchanged, only change the inlet water temperature, the heat exchange power of the entire heat exchange process increases with the increase of the inlet water temperature, which means that the cooling tower has a stronger heat dissipation capacity.

The influence of air flow:

Control other factors unchanged and only change the air flow. As the air volume increases, the air volume per unit of water contact increases, and the cooling tower's heat dissipation capacity increases.

Influence of water volume:

Control other factors unchanged, only change the water volume. As the cooling tower's circulating water volume increases, the air volume per unit of water contact decreases, and the heat exchange decreases. The outlet water temperature increases with the increase in the inlet temperature and outlet temperature of the circulating cooling water. The temperature difference decreases, so the cooling capacity of the cooling tower decreases.

 

Product Details and Warranty

We supply suitable spare pats according to experiment requirement, our products take aluminum structure, A4 paper dimension aluminum and plastic hanging box structure.

We supply 3 years warranty time.

 

Packaging & Delivery

Package details: plastic film+ plastic foam + plywood box with pallet, and for equipment dimension less than 1CBM, we supply plastic film+ plastic foam+ fine carton.

Arrange delivery within 45 days upon receipt of payment.

Please see below photo for detailed package.

 

 


Training Room Photo

 

 


Company Information

We supply professional educational training equipment and technical teaching equipment, which has been widely applied in Engineering Universities, Polytechnics, Technical Institute, Vocational Schools as well as Industry workforce Development Programs and Training Center. Our products allow students to learn and experiment through valuable hands-on experience, and the technology covered by our training equipment provides knowledge, experiments and didactic skills development that are of critical importance to today´s and tomorrow´s careers.

 


Photo for Clients Visiting Factory


Service

We supply supply7*24 hours service, customer design service, OEM service, buyer label service. With professional engineers team and sales team, we assure you good product quality.

 

Certificate
Our products takes ISO9001 product management system.

 

No. Feature Name Details
1 Customer design Yes
2 Warranty 1 year, 2 years, 3 years or 5 years according to client requirements
3 Package Plastic film+ carton+ Fine plywood
4 Products standard International didactic equipment standard
5 Application range Educational equipment for university, college, vocational training centers
6 Company philosophy Supply best quality Chinese products to the worldwide schools.
7 Self owned brand Shouldshine, SSEDU, JSS.
8 Production time From 10 days to 60 days according to different items
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company,Seller

  • Year Established:

    2012

  • Total Annual:

    3000000-5000000

  • Employee Number:

    120~150

  • Ecer Certification:

    Active Member

Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Fluid Lab Equipment, air conditioner trainer, refrigeration trainer, Thermal Lab Equipment, Vocational Training Equipment, Didactic Equipment, Engineering Educational Equipment, Technical Teaching Equip... Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Fluid Lab Equipment, air conditioner trainer, refrigeration trainer, Thermal Lab Equipment, Vocational Training Equipment, Didactic Equipment, Engineering Educational Equipment, Technical Teaching Equip...

+ Read More

Get in touch with us

  • Reach Us
  • Jinan Should Shine Didactic Equipment Co., Ltd.
  • No.15126 Century Avenue, Room 1-1612, Building 1, High Tech Zone,Jinan,China
  • https://www.vocationaleducationequipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement