Payment Terms | L/C, T/T, D/A, D/P, Western Union |
Supply Ability | 500 SET YEAR |
Delivery Time | 30 |
Packaging Details | Fine Plywood Box |
Product name | Wet Cooling Tower |
Usage | Heat Transfer Lab Equipment |
Package | Fine Plywood Box |
Warranty | 2 years |
Brand Name | SSEDU |
Model Number | ZT0022 |
Certification | ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
Tubular Heat Exchanger Didactic Equipment Heat Transfer Laboratory Equipment
H112 Thermal Transfer Equipment Marcet Boiler Apparatus
Heat Exchanger Vocational Training Equipment With Adjustable Loop Flow
SR 210 Convection Experiment Heat Transfer Didactic Sanitation Fittings Training
Product Specification
Payment Terms | L/C, T/T, D/A, D/P, Western Union | Supply Ability | 500 SET YEAR |
Delivery Time | 30 | Packaging Details | Fine Plywood Box |
Product name | Wet Cooling Tower | Usage | Heat Transfer Lab Equipment |
Package | Fine Plywood Box | Warranty | 2 years |
Brand Name | SSEDU | Model Number | ZT0022 |
Certification | ISO9001 | Place of Origin | China |
High Light | Educational Heat Transfer Lab Equipment ,Wet Cooling Tower Heat Transfer Equipments ,Wet Ventilation Heat Transfer Equipments |
ZT0022 Wet Cooling Tower Educational Equipment Heat Transfer Lab Equipment
I. Product content
1 Product overview
1.1 Overview
The ZT 0022 countercurrent wet ventilation cooling tower experimental platform is a training device used by the laboratory to verify the principle of forced convection heat transfer in the cooling tower. During the experiment, the water in the circulation loop is sprayed on the tower packing through the atomization spray device. Fans are arranged under the tower to realize forced convection heat exchange. During the process, part of the heat is transferred from water to the air, and the water temperature, air temperature, air humidity, air flow, water flow, etc. are recorded through the meter in the circulation of the experimental platform. The data achieves the purpose of experimental analysis. The data can be directly displayed on the display screens of the console, or transmitted to the PC through a USB device for further processing.
1.2 Features
The water flow and air flow in the working cycle of the experimental bench can be adjusted;
The data of each point of the workbench cycle can be digitally displayed by instruments (including water temperature, air temperature, water flow, air flow);
The data of each point of the workbench cycle can be displayed on the PC through a USB device;
According to the needs of the design experiment, the workbench is equipped with a replaceable cooling tower body for comparison research;
2 Preview Content
2.1 The main factors affecting heat and moisture transfer
In a cooling tower under normal operation, the main factors that affect the heat transfer process of the cooling tower are the inlet air wet bulb temperature (absolute saturation temperature), inlet water temperature, air volume, and circulating water volume. These four factors, of which water volume and air volume The ratio of is called the water-to-air ratio.
The influence of the inlet air wet bulb temperature:
Control other influencing factors unchanged (inlet water temperature, water volume, air volume), the heat transfer power (enthalpy difference) of the entire heat transfer process decreases with the increase of outdoor air wet bulb temperature, which means that the cooling tower's heat dissipation capacity is worse .
The influence of inlet water temperature:
Control other factors unchanged, only change the inlet water temperature, the heat exchange power of the entire heat exchange process increases with the increase of the inlet water temperature, which means that the cooling tower has a stronger heat dissipation capacity.
The influence of air flow:
Control other factors unchanged and only change the air flow. As the air volume increases, the air volume per unit of water contact increases, and the cooling tower's heat dissipation capacity increases.
Influence of water volume:
Control other factors unchanged, only change the water volume. As the cooling tower's circulating water volume increases, the air volume per unit of water contact decreases, and the heat exchange decreases. The outlet water temperature increases with the increase in the inlet temperature and outlet temperature of the circulating cooling water. The temperature difference decreases, so the cooling capacity of the cooling tower decreases.
Product Details and Warranty
We supply suitable spare pats according to experiment requirement, our products take aluminum structure, A4 paper dimension aluminum and plastic hanging box structure.
We supply 3 years warranty time.
Packaging & Delivery
Package details: plastic film+ plastic foam + plywood box with pallet, and for equipment dimension less than 1CBM, we supply plastic film+ plastic foam+ fine carton.
Arrange delivery within 45 days upon receipt of payment.
Please see below photo for detailed package.
Training Room Photo
Company Information
We supply professional educational training equipment and technical teaching equipment, which has been widely applied in Engineering Universities, Polytechnics, Technical Institute, Vocational Schools as well as Industry workforce Development Programs and Training Center. Our products allow students to learn and experiment through valuable hands-on experience, and the technology covered by our training equipment provides knowledge, experiments and didactic skills development that are of critical importance to today´s and tomorrow´s careers.
Photo for Clients Visiting Factory
Service
We supply supply7*24 hours service, customer design service, OEM service, buyer label service. With professional engineers team and sales team, we assure you good product quality.
Certificate
Our products takes ISO9001 product management system.
No. | Feature Name | Details |
1 | Customer design | Yes |
2 | Warranty | 1 year, 2 years, 3 years or 5 years according to client requirements |
3 | Package | Plastic film+ carton+ Fine plywood |
4 | Products standard | International didactic equipment standard |
5 | Application range | Educational equipment for university, college, vocational training centers |
6 | Company philosophy | Supply best quality Chinese products to the worldwide schools. |
7 | Self owned brand | Shouldshine, SSEDU, JSS. |
8 | Production time | From 10 days to 60 days according to different items |
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2012
Total Annual:
3000000-5000000
Employee Number:
120~150
Ecer Certification:
Active Member
Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Fluid Lab Equipment, air conditioner trainer, refrigeration trainer, Thermal Lab Equipment, Vocational Training Equipment, Didactic Equipment, Engineering Educational Equipment, Technical Teaching Equip... Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Fluid Lab Equipment, air conditioner trainer, refrigeration trainer, Thermal Lab Equipment, Vocational Training Equipment, Didactic Equipment, Engineering Educational Equipment, Technical Teaching Equip...
Get in touch with us
Leave a Message, we will call you back quickly!