China factories

China factory - XI'AN BEICHENG ELECTRONICS CO.,LTD

XI'AN BEICHENG ELECTRONICS CO.,LTD

  • China
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Shockproof Electric Power Tester
China Shockproof Electric Power Tester

  1. China Shockproof Electric Power Tester
  2. China Shockproof Electric Power Tester
  3. China Shockproof Electric Power Tester
  4. China Shockproof Electric Power Tester

Shockproof Electric Power Tester

  1. MOQ: 1pcs
  2. Price: USD1200/pc
  3. Get Latest Price
Payment Terms T/T, Western Union, L/C, Paypal
Supply Ability 10000PCS
Delivery Time 5 to 30 days
Packaging Details Color box ,1pcs/Carton ,10.5KG/Carton
Color Black and Orange
Packing color box
Weight Approx 1200g
Display Mode 5.6-inch LCD display
Dimension 240mm×170mm×68mm
Power Rechargeable lithium-ion battery pack 9.6V
Communication USB
Product Name Power Quality Analyzer
Brand Name VICTOR
Model Number VICTOR 5000
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, L/C, Paypal Supply Ability 10000PCS
Delivery Time 5 to 30 days Packaging Details Color box ,1pcs/Carton ,10.5KG/Carton
Color Black and Orange Packing color box
Weight Approx 1200g Display Mode 5.6-inch LCD display
Dimension 240mm×170mm×68mm Power Rechargeable lithium-ion battery pack 9.6V
Communication USB Product Name Power Quality Analyzer
Brand Name VICTOR Model Number VICTOR 5000
Certification CE Place of Origin CHINA
High Light Shockproof Electric Power TesterVICTOR 5000 Electric Power TesterShockproof Power Quality Analyzer

VICTOR5000 Power Quality Analyzer Large LCD Screen Display High Resolution Shock-Proof Shell StructureTrue RMS

 

Brief Introduction

Power Quality Analyzer is a comprehensive test instrument carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, concise man-machine operation. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.

 

In the current power applications, more and more large power equipment, power grid fault have become more and more complex, with development of the industry, it put forward high request more and more to quality that electric energy. We provide this power quality analyzer for that, which you can troubleshoot of complex power system more quickly and accurate, and monitoring and maintenance of power quality parameters more comprehensive and systemic.

 

Power quality analyzer adopt DSP + ARM double processor architecture, DSP is use for data collection and the processing of algorithm, the ARM is use for the communication protocol and the man-machine interface processing; Analog signal acquisition is by 2 pieces AD7655 of ADI company. Resolution for AD7655 is 16 bit and it is 4 channel synchronous sampling. The highest sampling rate can reach 1 MSPS, to ensure the accuracy of the channel and the information integrity, and wouldn’t miss any transient changes in the grid, can more accurate to detect the transient waveform rising and dropping drastically, and waveform instantaneous interrupt; DSP working frequency is over 200 MHZ, to be able to timely monitoring of the power grid and dynamically adjust the sampling frequency to realize synchronization of power frequency and sampling frequency; Using a 5.6 -inch LCD color screen display, a resolution of 640 dots x 480 dots, with different display color difference between the parameters of phase, waveform, vector diagram, harmonic ratio, the user can be more efficient and more intuitive understand the state of power grid parameters. Built-in flash memory can store 60 group of screenshots at the same time, 150 groups of capture transient voltage/current waveform figure, and 12800 groups of alarm list. Starting current detection model can continuously capture starting current waveform for 100 s. Built-in 2G memory card to store the trend curve record, simultaneous recording 20 parameters (can choose according to need) collect data for once every five seconds, trend curve records can be stored for 300 days.

 

Power Quality Analyzer also named: Intelligent Three Phase Power Quality Analyzer, Multifunctional Power Quality Analyzer, which simultaneous with the functions of harmonic Analyzer, phase volt-ampere meter, electric parameter tester. It apply to electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institution, metrological department. Especially suitable for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, phase electric parameters.

1.2. Function

1.2.1. Basic function

★ Waveform real-time display (4 channels voltage/4 channels current).

★ True RMS values of voltages and currents.

★ The DC components of voltages.

★ Peak current and voltage values.

★ Minimum and maximum half-cycle RMS current and voltage values.

★ Pharos diagram display.

★ Measurement of each harmonic up to order 50.

★ Bar charts show harmonic ratios of current and voltage of each phase.

★ Total harmonic distortion (THD).

★ Active, reactive, apparent power, by phase and cumulative.

★ Active, reactive, apparent energy, by phase and cumulative.

★ Transformer K factor.

★ Power factors (PF) and displacement factors (DPF or COSΦ).

★ Short-term voltage flicker (PST).

★ Three phase unbalance(current and voltage).

 

Technology specification

Base condition and working condition

Influence factor Test item Base condition Working condition
Environment temperature All parameters (23±2)°C -10°C~ 40°C
Relative humidity All parameters 40%~ 60% <80%
Phase-to-neutral voltage All parameters (100±1%)V 1.0V~ 1000V
Phase-to-phase voltage True RMS phase-to-phase voltage (200±1%)V 1.0V~ 2000V
Current True RMS current (5±1%)A 10mA~ 1000A
Network frequency All parameters 50Hz±0.1Hz 40Hz~ 70Hz
Phase shift Active power and active energy Cosφ=1 Cosφ: 0.2~ 1.0
Reactive power and reactive energy Sinφ=1 Sinφ: 0.2~ 1.0
Harmonic All parameters <0.1% 0.0%~ 100%
Voltage unbalance All parameters <10% 0.0%~ 100%
Working voltage of device All parameters DC9.8V±0.1V DC9.5V~ 10.5V

External electric field,

magnetic field

All parameters Should be avoided
Test position Measured related parameters of current Tested wire at the center of clamp.

1.3.2. General specification

Power supply Rechargeable lithium-ion battery packs 9.6V, backup charger.
Battery indicator Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.
Power consumption Current consumption of normal test 490 mA, continuous working for 8 hours.
Display mode LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm.
Size of clamp

008 small sharp current clamp: 7.5mm×13mm;

040circle current clamp: 35mm×40mm;

068Bcircle current clamp: 68mm×68mm.

300F Flexible Coil Current Sensor (with Integrator) : Ф300mm

Instrument dimensions L×W×H: 240mm×170mm×68 mm.
Number of channels 4U/4I.
Phase-to phase voltage 1.0V~2000V.
Phase-to-neutral voltage 1.0V~1000V.
Current

008B current clamp: 10mA~10.0A;

040B current clamp: 0.10A~100A;

068B current clamp: 1.0A~1000A;

300F Flexible Coil Current Sensor (with Integrator) : 10A ~ 3000A

Frequency 40Hz~70Hz.
Parameters of electricity W, VA, Var, PF, DPF, cosφ, tanφ.
Energy parameters Wh, Varh, Vah.
Harmonic Order 0~50.
Total harmonic distortion Order 0~50, each phase.
Expert mode Yes.
Number of Transient records 150 sets.
Voltage flicker Yes.
Starting current mode Yes, 100 seconds.
3 phases unbalance Yes.
Record 300 days(simultaneous recording 20 parameters, record one point every 5 seconds).
Min/Max recorded value Measurement of maximum and minimum values over a period of time.
Alarm 40 different types of parameter selections, 12,800 sets alarm logs.
Peak Yes.
Phasor diagram display Automatically.
Capacity of snapshots 60.
Menu language English/Chinese.
Communication USB.
Automatic switching off When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress,the device is not automatic switching off.
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.
Backlight function Yes, suitable for use at night and dark place.
Weight Host: 1.6kg (with battery).
008B small sharp current clamp: 170g×4;
040Bcircle current clamp: 190g×4;
068Bcircle current clamp: 510g×4;
300F Flexible Coil Current Sensor (with Integrator) : 330g×4;
Test wires and power adapter: 900g;
Total weight: about 9.2kg (with packaging).
Length of voltage test wire 3m.
Length of current sensor wire 2m.
Working temperature and humidity -10°C~40°C; below 80%Rh.
Storage temperature and humidity -10°C~60°C; below 70%Rh.
Input impedance Input impedance of test voltage:1MΩ.
Withstand voltage Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.
Insulation Between instrument wiring and shell ≥10MΩ.
Structure Double insulation, with insulation vibration-proof sheath.
Safely rules IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.

Instrument precision (excluding the current sensor)

Respectively introduce the following data (on the basic of base conditions and the ideal current sensors, perfectly linear, no phase shift).

Measurement Range Display resolution The maximum error in the range of the reference
Frequency 40Hz~ 70Hz 0.01Hz ±(0.03)Hz
True RMS phase-to-neutral voltage 1.0V~ 1000V Min resolution 0.1V ±(0.5%+5dgt)
True RMS phase-to phase voltage 1.0V~ 2000V Min resolution 0.1V ±(0.5%+5dgt)
DC voltage 1.0V~ 1000V Min resolution 0.1V ±(1.0%+5dgt)
True RMS current 10mA~ 1000A Min resolution 1mA ±(0.5%+5dgt)
Peak of phase-to-neutral voltage 1.0V~ 1414V Min resolution 0.1V ±(1.0%+5dgt)
Peak of phase-to-phase voltage 1.0V~ 2828V Min resolution 0.1V ±(1.0%+5dgt)
Current peak 10mA~ 1414A Min resolution 1mA ±(1.0%+5dgt)
Peak factor 1.00~ 3.99 0.01 ±(1%+2dgt)
4.00~ 9.99 0.01 ±(5%+2dgt)
Active power 0.000W~ 9999.9kW Min resolution 0.001W

±(1%+3dgt)

Cosφ≥0.8

±(1.5%+10dgt)

0.2≤Cosφ<0.8

Reactive power, inductive or capacitive

0.000VAR~

9999.9kVAR

Min resolution 0.001VAR

±(1%+3dgt)

Sinφ≥0.5

±(1.5%+10dgt)

0.2≤Sinφ<0.5

Apparent power

0.000VA~

9999.9kVA

Min resolution 0.001VA ±(1%+3dgt)
Power factor -1.000~ 1.000 0.001

±(1.5%+3dgt)

Cosφ≥0.5

±(1.5%+10dgt)

0.2≤Cosφ<0.5

Active energy 0.000Wh~ 9999.9MWh Min resolution 0.001Wh

±(1%+3dgt)

Cosφ≥0.8

±(1.5%+10dgt)

0.2≤Cosφ<0.8

Reactive energy, inductive or capacitive

0.000VARh~

9999.9MVARh

Min resolution 0.001VARh

±(1%+3dgt)

Sinφ≥0.5

±(1.5%+10dgt)

0.2≤Sinφ<0.5

Papparent energy

0.000VAh~

9999.9MVAh

Min resolution 0.001VAh ±(1%+3dgt)
Phase angle -179°~ 180° ±(2°)

Tanφ

(VA≥50VA)

-32.76~ 32.76 Min resolution 0.001 φ:±(1°)

Phase shift of power factor

(DPF)

-1.000~ 1.000 0.001 φ:±(1°)

Harmonic ratio

(order 1 to 50) (Vrms>50V)

0.0%~ 99.9% 0.1% ±(1%+5dgt)

Harmonic angle

(Vrms>50V)

-179°~ 180° ±(3°) harmonics of order 1 to 25
±(10°) harmonics of order 26 to 50

Total harmonic ratio

(THD or THD-F)≤50

0.0%~ 99.9% 0.1% ±(1%+5dgt)

Distortion factor

(DF or THD-R)≤50

0.0%~ 99.9% 0.1% ±(1%+10dgt)
Transformer K factor 1.00~ 99.99 0.01 ±(5%)
3 phases unbalance 0.0%~ 100% 0.1% ±(1%)

1.3.4. Current sensor character

Type of current sensor True RMS current Max error of true RMS current Max error of phase angleφ
008B current clamp 10mA~ 99mA ±(1%+3dgt) ±(1.5°),Arms≥20mA
100mA~ 10.0A ±(1%+3dgt) ±(1°)
040B current clamp 0.10A~ 0.99A ±(1%+3dgt) ±(1.5°)
1.00A~ 100A ±(1%+3dgt) ±(1°)
068B current clamp 1.0A~ 9.9A ±(2%+3dgt) ±(3°)
10.0A~ 1000A ±(2%+3dgt) ±(2°)
300F Flexible Coil Current Sensor (with Integrator) 10A~99A ±(1 % + 3dgt) ±(3°)
100AA~3000A ±(1 % + 3dgt) ±(2°)

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Year Established:

    1980

  • Total Annual:

    4000000-5000000

  • Employee Number:

    200~500

  • Ecer Certification:

    Site Member

VICTOR Instruments is a brand  belongs to Xi'an Beicheng Electronics Co.Ltd. (former Victor Instruments ) which was established in 1980s,VICTOR specializes in producing test instruments and especially digital multimeters. Our products include analog and digital multimeters, clamp-... VICTOR Instruments is a brand  belongs to Xi'an Beicheng Electronics Co.Ltd. (former Victor Instruments ) which was established in 1980s,VICTOR specializes in producing test instruments and especially digital multimeters. Our products include analog and digital multimeters, clamp-...

+ Read More

Get in touch with us

  • Reach Us
  • XI'AN BEICHENG ELECTRONICS CO.,LTD
  • JINGYUAN 7 ROAD, JINGHE INDUSTRIAL PARK, NORTH DISTRICT,XI'AN,CHINA  710200
  • https://www.victormultimeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement