Payment Terms | T/T, Western Union, L/C, Paypal |
Supply Ability | 1000pcs available |
Delivery Time | 5 to 30 days |
Packaging Details | 6pcs/Carton; Carton Size: 103*45*45cm;20.5KG/Carton |
LCD Display | 3.5 inch TFT Display |
Size | 265mmx105mmx305mm |
Material | Plastic, metal, silica gel |
Product Name | Digital LCR Meter |
Model No. | 4090A |
Packing Details | 6pcs/Carton; Carton Size: 103*45*45cm;20.5KG/Carton |
Brand Name | VICTOR |
Model Number | 4090A |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
100KHz Handheld LCR Meter High Precision Measure Inductance Multimeter
SCPI LCR Digital Meters 10 Hz 20 KHz Bandwidth Frequency Adjustable
4091A RS232 Interface 10 KHZ LCR Digital Bridge With Kelvin Clamp
HandHeld LCR Digital Meters LCD Display SMD Smart Tweezer
Product Specification
Payment Terms | T/T, Western Union, L/C, Paypal | Supply Ability | 1000pcs available |
Delivery Time | 5 to 30 days | Packaging Details | 6pcs/Carton; Carton Size: 103*45*45cm;20.5KG/Carton |
LCD Display | 3.5 inch TFT Display | Size | 265mmx105mmx305mm |
Material | Plastic, metal, silica gel | Product Name | Digital LCR Meter |
Model No. | 4090A | Packing Details | 6pcs/Carton; Carton Size: 103*45*45cm;20.5KG/Carton |
Brand Name | VICTOR | Model Number | 4090A |
Certification | CE | Place of Origin | CHINA |
High Light | Desktop LCR Digital Meters ,TFT Display LCR Digital Meters ,VICTOR 4090A |
Desktop LCR Digital Meters With Automatic Balance Bridge Principle
VICTOR 4090A LCR Meter Desktop Bridge LCR With Automatic Balance Bridge Principle Component Parameter Analyzer
Description
This series desktop bridge incorporates 3.5-inch TFT display, user-friendly interface, and a variety of measurement parameters into one body. It is convenient for users to carry out remote control with USB and RS232 and also perform the sorting of components using handle. In function, it can not only adjust the output frequency and test level, but also record the value of components in the process of measurement. In the performance parameters, its basic accuracy reaches 0.2%. This manual will take “Type A” as an example.
● Measurement frequency up to 100kHz ● Test level 100 ~ 2000mV ● Support the measurement of DC resistance and electrolytic capacitor ● Internal bias voltage output (1mV-1500mV) ● Automatic identification of component measurement ● 3.5-inch TFT display, 5 and a half bits display ● USB, RS232 communication interface, Handle sorting ● Data recording function (maximum and minimum values, average value) | ● Support SCPI communication protocol ● Provide system settings, which can configure language, buzzer, screen brightness, etc according to the needs of users. ● Basic accuracy 0.2% ● Manual and automatic range ● Be equipped with open circuit and short circuit correction ● Comparator has sorting and alarm function ● Provide a variety of test ports |
General technical specifications
Standard accessories:
Optional accessories:
Model | VC4090A | VC4090B | VC4090C | VC4091A | VC4091B | VC4091C | |
Testing frequency | 10Points(100, 120,200, 400,800, 1K,2K, 4K,8K,10K) | 12Points(100,120, 200,400,800, 1K,2K, 4K,8K,10K,15K, 20K) | 16Points(100,120, 200,400,800, 1K,2K, 4K,8K,10K,15K, 20K,40K,50K,80K, 100K) | 10~10KHz Continuously adjustable, a step of 1 Hz | 10~20KHz Continuously adjustable, a step of 1 Hz | 10~100KHz Continuously adjustable, a step of 1 Hz | |
Display screen | 3.5” TFT LCD screen | ||||||
Number of display digits | Principal parameter: 5 digit Secondary parameter: 5 digit | ||||||
Measured parameter: | Principal parameter: L/C/R/Z Secondary parameter: X/D/Q/θ/ESR | ||||||
Measurement range | L:0.001µH~99999H, C:0.001pF~99.999mF, R:0.0001Ω~99.999MΩ | ||||||
Basic accuracy | 0.2% | ||||||
Measuring display speed | 2 time/s (slow), 4 times/s (medium), 8 time/s (fast) | ||||||
Internal bias | 0-1500mV adjustable, at a step of 1mV. | ||||||
Testing level | Six fixed level(0.1V,0.3V,0.6V,1V,1.5V,2V) | 0.1~2V adjustable, at a step of 1mV. | |||||
Signal source output impedance | 30Ω,100Ω | ||||||
Calibration function | Open circuit calibration, short circuit calibration | ||||||
Screening function | The limit range of screening can be set to -50%~+50%, and the fixed points are 1%, 5%, 10% and 20%. | ||||||
Comparator | 5 groups sorting,3 groups of qualified setting, one group of unqualified setting, one group of auxiliary setting | ||||||
Interfaces | standard: RS232(or 485), USB Device, Handler ;optional :GPIB,USB Host | ||||||
Others | Support dc resistance (DCR), electrolytic capacitor measurement model,Adjustment of backlight brightness, Chinese and English are optional |
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
1980
Total Annual:
4000000-5000000
Employee Number:
200~500
Ecer Certification:
Site Member
VICTOR Instruments is a brand belongs to Xi'an Beicheng Electronics Co.Ltd. (former Victor Instruments ) which was established in 1980s,VICTOR specializes in producing test instruments and especially digital multimeters. Our products include analog and digital multimeters, clamp-... VICTOR Instruments is a brand belongs to Xi'an Beicheng Electronics Co.Ltd. (former Victor Instruments ) which was established in 1980s,VICTOR specializes in producing test instruments and especially digital multimeters. Our products include analog and digital multimeters, clamp-...
Get in touch with us
Leave a Message, we will call you back quickly!