Payment Terms | Western Union, T/T, L/C, D/A, D/P, PayPal |
Supply Ability | 15000pcs per Month |
Delivery Time | 3 days, depend on the order quantity |
Packaging Details | Carton and Wooden Box |
Product Name | IP20 380V 5.5KW Solar Pump Inverter |
Current | 13A |
Keypad | LED/LCD |
Working Principle | AC-DC-AC |
Frequency | 50HZ/60HZ |
Colar | Blue |
Brand Name | VEIKONG |
Model Number | VFD500-PV |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
MPPT VFD Solar Pump Inverter for 2.2kW and 4kW Three Phase Solar Pumping System
Three Phase 30kw 37kw 530VDC MPPT VFD Solar Pump Inverter support GPRS
3 Phase 5500W MPPT VFD Solar Pump Inverter Support GPRS
Advanced MPPT Algorithm 380V 15kw 20hp Solar Pump Inverter with GPRS Remote
Product Specification
Payment Terms | Western Union, T/T, L/C, D/A, D/P, PayPal | Supply Ability | 15000pcs per Month |
Delivery Time | 3 days, depend on the order quantity | Packaging Details | Carton and Wooden Box |
Product Name | IP20 380V 5.5KW Solar Pump Inverter | Current | 13A |
Keypad | LED/LCD | Working Principle | AC-DC-AC |
Frequency | 50HZ/60HZ | Colar | Blue |
Brand Name | VEIKONG | Model Number | VFD500-PV |
Certification | CE | Place of Origin | China |
High Light | 13A MPPT VFD Solar Pump Inverter ,5.5KW MPPT VFD Solar Pump Inverter ,IP20 GPRS Solar Pump Inverter |
IP20 380V 5.5KW Solar Pump Inverter With 99% MPPT Tracking and GPRS Function
1. Operates without grid directly from photovoltaic (PV) cells
2. Automatic start and stop with solar radiation
3. Built-in maximum power point tracking (MPPT)
4. Easy installation and set-up for serial production
5. Compatible with all pump types
6. Good ROI (Return on Investment) against diesel powered pumping
7. Compact and uniform drive module design (IP20)
8. Dual supply capability with change over switch - solar and grid compatible
9. Sensorless vector control of induction motors and permanent magnet motors
10. Energy saving function and dry run self learning function 11 GPRS monitoring control via PC and Mobile
Solar Pump Inverter Special Parameters
Function code | Name | Description | Default | Property |
47 Group solar pumping special group | ||||
P00.03 | RESET | 0:NO ACTION 11:Restore default parameter except for motor parameter and auto-tune related parameter and factory parameter 12:Restore default to factory parameter 13:Clear tripping record | 0 | ★ |
P00.06 | Source of the Operation Command | 0:keypad 1:terminal 2:communication Ø Command source: run,stop,forward,reverse,jog,fast brake stop.etc | 0 | ★ |
P00.07 | Numeric frequency setting | 00.00Hz~maximum frequency | 50.00Hz | ☆ |
P00.11 | Application Macro | 01:Output three phase 50HZ 02:Output three phase 60hz 21:Output single phase with capacitor 50hz 22:Output single phase with capacitor 60hz 31:Output single phase without capacitor 50hz 32:Output single phase without capacitor 60hz | 00 | ★ |
P01.06 | Maximum frequency | 10.00~600.00Hz | 50.00Hz | ★ |
P01.08 | Upper limit frequency | Lower limit frequency-maximum frequency | 50.00Hz | ☆ |
P07.03 | Relay 1 Output terminal function group(T1A T1B T1C) | 0:No function 1:READY 2:RUN 3:Error1(stop fault) 4:Error2(same as Error1 except undervoltage) 5:Warning output(fault but in running) | 3 | ☆ |
P11.01 | AC asynchronous motor TYPE | 0:Three phase AC asynchronous motor 1:Single phase AC asynchronous motor without starting capacitor | 0 | ★ |
P11.02 | Motor rated power | 0.1kW~710.0kW Ø when power is less than 1kw ,0.75kw set to 0.8 as per round up principle ,0.55kw motor set 0.6 Ø when change motor rated power,AC drive will automatically set other parameter of motor name plate and motor model parameter be careful to use | Depend | ★ |
P11.03 | Motor rated voltage | 10V~2000V | Depend | ★ |
P11.04 | Motor rated current | P11.02<30kW:0.01A P11.02>=30kW:0.1A | Depend | ★ |
P11.05 | Motor rated frequency | 1.00Hz~600.00Hz | 50.00Hz | ★ |
P11.06 | Motor rated RPM | 1~60000rpm | Depend | ★ |
P21.00 | Monitoring display | 0:Standard mode (display frequency only) 1:Automatic scrolling display(Check 3.1 in detail )it show hz,current,power and voltage | 0 | ★ |
P23.15 | Output phase loss function | 0.0-30%, 0% means output phase detections shielded | 30% | ☆ |
r27.15 | Accumulative running time | Unit:hour | ● | |
P47.00 | Solar pump Mppt function enable | 0: invalid The parameters behind the 47 group cannot be changed! 1: Enable, to enable the special mppt function of the PV pump inverter
| 1 | ★ |
P47.01 | Solar pump control mode
| Units digit’s: Startup mode 0: Manual start, the start mode is determined by P00.06; 1: automatic start, When P00.06 change, the association changes here. P00.06=0, when inverter starts and stops by keypad control, it is automatically modified to 1-automatic start P00.06=1, when inverter starts and stops by terminal control.it is automatically changed to 0-manual start Ten digit’s: MPPT function 0: MPPT is disabled; CVT control is used (voltage is given as P47.04). 1: Enable MPPT. | 11 | ★ |
P47.03 | Automatic start timing | In auto start mode, set the time from power on to start. It is also waiting time to start | 600 | ★ |
P47.04 | MPPT starting voltage | Set the starting voltage of the MPPT algorithm. When the MPPT function is disabled, this value is the reference voltage. | 305V(530V) | ★ |
P47.05 | Light detection threshold | If the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop | 0Hz | ☆ |
P47.06 | Light detection time | See P47.05 for explanation. | 60s | ☆ |
P47.07 | Light weak wake up time | After the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues. | 600s | ☆ |
P47.08 | MPPT tracking step length | The amount of change in the bus voltage during an MPPT cycle. The larger the value, the faster the maximum power point is found, but the lower the accuracy of the maximum power point. | 2V | ☆ |
P47.09 | Regulator proportional gain | 0.001~1.00 It is for immediate response speed, it is not recommended to change | 0.05 | ☆ |
P47.10 | Regulator integral gain | 0.001~0.100 tracking response.it is not recommended to change | 0.05 | ☆ |
P47.28 | Starting coefficient | 0.000~1.000 | 0.850 | ☆ |
P47.30 | Fast speed function | Unit digit:fast starting 0:Disable 1:Enable Ten digit:Fast mppt tracking 0:Disable 1:Enable | 11 | ☆ |
Product Application
FAQ
1. Does the product need to set a lot of parameters?
No, it doesn't. The inverter has a self-adaptive and self-learning function. It is automatic start and stop, you can press Run key to start, or you just wait for P47.03=600S(Default) then it will automatically start
2. Could it replace my previous PV pumping inverter?
Yes, of course. Selecting inverter model according to the rated voltage, current and power of the water pump. A bit more is better. Then take off the old one and put ours on, the system will work.
3. How to design solar PV water pump system?
Key point: the rated VOC and VMP and power of the PV Array need to match the input range of the inverter. If needed, we will provide technical support online.
4. How to make the water pump system work without sunshine?
Usually, solar PV water pump system can meet the needs of pumping water.
If there is no sunshine, the system will not work. But out inverter could also support AC input. So, connect the power grid or diesel power generation to the inverter, the pumping system will work. If necessary, keep switch and interface locations during the system design
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2013
Total Annual:
15000000-20000000
Employee Number:
201~500
Ecer Certification:
Verified Supplier
Shenzhen VEIKONG Electric CO.,Ltd. a high-tech enterprise which has been specializing in researching, manufacturing and trading high, medium and low voltage inverter, providing our clients with integrated system solutions. We have professional R&D and devoted management team with more than 20 ye... Shenzhen VEIKONG Electric CO.,Ltd. a high-tech enterprise which has been specializing in researching, manufacturing and trading high, medium and low voltage inverter, providing our clients with integrated system solutions. We have professional R&D and devoted management team with more than 20 ye...
Get in touch with us
Leave a Message, we will call you back quickly!