Payment Terms | Western Union, T/T, L/C, D/A, D/P, PayPal |
Supply Ability | 15000pcs per Month |
Delivery Time | 3 days, depend on the order quantity |
Packaging Details | Carton |
Product Name | 132kw reactor |
Material | Copper |
Output type | Triple |
Type | AC Drive |
Input voltage | 380V |
Protection | IP20 |
Brand Name | VEIKONG |
Model Number | VKS |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
VEIKONG DC Reactor Choke For AC Frequency Inverter VFD Core-Winding Insulation
Inverter Reactor for Solar Pump System AC Output 3-Phase 400V 20A 7.5KW
VEIKONG 2% Voltage Drop AC Output Reactor For Vfd 45kw 55kw Ac Drive Inverter
VEIKONG Safe and Reactive Strength and Insulation Resistance Inverter Reactor
Product Specification
Payment Terms | Western Union, T/T, L/C, D/A, D/P, PayPal | Supply Ability | 15000pcs per Month |
Delivery Time | 3 days, depend on the order quantity | Packaging Details | Carton |
Product Name | 132kw reactor | Material | Copper |
Output type | Triple | Type | AC Drive |
Input voltage | 380V | Protection | IP20 |
Brand Name | VEIKONG | Model Number | VKS |
Certification | CE | Place of Origin | China |
High Light | 160kw Vfd Line Reactor ,132KW Vfd Line Reactor |
AC choke 400V AC 50HZ 300A output reactor used for 132KW motor
VKS-OCL series Load Reactors are placed in series with electrical equipment to introduce a specific controlled impedance to the AC circuit. This series are applied at AC drive output side to suppress inrush voltage, reducing inrush and peak current, improving real power factor, restraining grid harmonics and improving the output current waveform. Line Reactor also known as Output Reactor.
Flexible Meterial Choice:Selection of silicon steel,ferrite magnetic material of amorphous core according to the frequency of application;
Excellent Property:Due to foll winding structure,small DC resistance, strong resistance to electromagnetic force, good overload ability in short time
Reliable Performance:F-class insulation materials are used, which ensure products maintain reliable performance in harsh working condition.
Low Noise: Designed with low magnetic flux density,the reactors of high linearit.With powerful overload sheets, the reactor noise is low
Rated operating power: 380V/690V/1140V
Operating frequency: 50/60Hz
Current range: 5-1600A
Operating ambient temperature: -25℃-50℃
Dielectric Strength: Core-winding,AC 3000V/50Hz/5mA/ free of demage in 60s (test in factory)
Insulation Resistance: Core-Winding,DC 1000V,Resistance >100M ohm
Noise: Less than 65dB(to be measured at the point 10 meter away from the reactor horizontally
Protection class: IP00
Insulation class: F/H
Standard: GB 19212.1-2008GB/T1094.6-2011
It is recommended to use input reactors in the following circumstances:
1. frequency converters in parallel close connection.
2. line power supply has obvious disturbance from other devices (interference, over voltage).
3. there is voltage imbalance between the phases of the line power supply, exceeding 1.8% of the rated voltage.
4. a large number of converters are installed on the same line.
5. reduce cos C overload on the correction capacitor if there is a power factor correction device in the device.
6. power supply capacity is 60KVA and above, and frequency converter installation location is within 10M of large capacity power supply.
7. the frequency converter is powered by a very low impedance line (10 times higher than the inverter's rated value).
Product Parameters
Voltage Range | DC500V-1000V |
Dielectric Strength | Core-Winding, AC 3000V/50Hz/5mA, free of damage in 60s |
Insulation Resistance | Core-Winding, DC 1000V, Resistance > 100M ohm |
Reactor's noise | less than 65dB(to be measured at the point 1 meter away from the reactor horizontally) |
Standard | GB 19212.1-2008 GB/T 1094.6-2011 |
Product Size
Summary
VEIKONG Input and output reactor for variable frequency speed regulation: inverter and governor during use, often suffer from the surge current and surge voltage impact, the performance will be severely damaged and the service life of the converter and the governor, so to use input reactor arranged on the front, to suppress the surge voltage and surge current protection, inverter and governor, extend the service life and prevent the harmonic interference, at the same time, as the frequency converter and adopts frequency conversion speed governor is the way, so often produce hormonics and waveform distortion in the speed, will affect the normal use of equipment, therefore, require the installation of a reactor output on the output side, to filter out the harmonic voltage and current, improve the quality of power grid. Our produced Input and output reactor, using high quality imported silicon steel sheet, the advanced technology refined, have the advantages of small volume, low temprature rise, no noise etc..
Our AC input and output reactor can match with SIEMENS, ABB, Hitachi, Toshiba, Matsushita, Sanken, Yaskawa, PU, Danfoss, Fuji, LG, OMRON, Continental, OMRON, moden Schneider, Lenze, Emerson, and other domestic and foreign brands converters.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2013
Total Annual:
15000000-20000000
Employee Number:
201~500
Ecer Certification:
Verified Supplier
Shenzhen VEIKONG Electric CO.,Ltd. a high-tech enterprise which has been specializing in researching, manufacturing and trading high, medium and low voltage inverter, providing our clients with integrated system solutions. We have professional R&D and devoted management team with more than 20 ye... Shenzhen VEIKONG Electric CO.,Ltd. a high-tech enterprise which has been specializing in researching, manufacturing and trading high, medium and low voltage inverter, providing our clients with integrated system solutions. We have professional R&D and devoted management team with more than 20 ye...
Get in touch with us
Leave a Message, we will call you back quickly!