Payment Terms | L/C, T/T, Western Union |
Supply Ability | 15000pcs per Month |
Delivery Time | depend on the order quantity |
Packaging Details | the power less than 45kw use Carton, starting from 45kw use Wooden case |
Product Name | 2.2kw 220v solar pump inverter |
Voltage | 220v/380v |
Type | single phase/three phase |
Display | LED+LCD |
Efficiency | 99% |
Special function | MPPT+ PID |
Original | China |
GPRS | Support |
PC tool communication | Support |
Warranty | 18 months |
Brand Name | VEIKONG |
Model Number | VFD500-PV |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
MPPT VFD Solar Pump Inverter for 2.2kW and 4kW Three Phase Solar Pumping System
Three Phase 30kw 37kw 530VDC MPPT VFD Solar Pump Inverter support GPRS
3 Phase 5500W MPPT VFD Solar Pump Inverter Support GPRS
Advanced MPPT Algorithm 380V 15kw 20hp Solar Pump Inverter with GPRS Remote
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 15000pcs per Month |
Delivery Time | depend on the order quantity | Packaging Details | the power less than 45kw use Carton, starting from 45kw use Wooden case |
Product Name | 2.2kw 220v solar pump inverter | Voltage | 220v/380v |
Type | single phase/three phase | Display | LED+LCD |
Efficiency | 99% | Special function | MPPT+ PID |
Original | China | GPRS | Support |
PC tool communication | Support | Warranty | 18 months |
Brand Name | VEIKONG | Model Number | VFD500-PV |
Certification | CE | Place of Origin | China |
High Light | Single Phase Vfd 3hp ,2.2kw Solar Ac Pump Controller ,Automatic Single Phase Vfd 3hp |
2.2kw 3HP single phase 220V Solar water Pump Inverter for ac pump
Smart:
Full automatic operation, no need programming, user-friendly
Modular design, easy install , operate & maintain
GPRS Moudle Support remote monitoring & control (2G/4G/WIFI for option)
Support LogEfficieo/Lable/Color/Function OEM Serive
Efficient:
1:1 match to AC pumps with strong overload capacity
30% more water output with advanced inverter control algorithm
Maximum power point tracking (MPPT) efficiency reach 99% with advanced MPPT algorithm
Built-in booster with lower solar operating voltage to reduce solar panels costs
Good ROI (Return on Investment) against diesel powered pumping
Reliable:
Hybrid function –Solar power priority, grid power/generator dual input as compensation
Key parts use famous brand components, longer service life
Wide range of input voltage
IP65 design, continuous full-load operation between -10℃ to +60℃
Compatible with all AC pumps (0.37kw-150kw)
Certification qualified from authoritative third party, inverters can be exported to all countries
Professional & Independent R&D team, good service for pre-sales and after-sales
Fast delivery and quick response
Comprehensive Protections:
Soft start
DC Input Anti-reverse
AC Input/Output Phase lost(3Phase)
AC Output Short Circuit
AC Output Unbalance (3Phase)
Pump Dry run protection By sensor/ software
Water Over Flow of Tank
Solar Low power
Over Load
AC Output Over Current
Electrical Specifications
PV input | |
Maxiumum input DC voltage | 400V DC |
Recommended MPPT voltage range | 250~350V DC |
Recommended input Operation Voltage | 310V DC |
Grid or backup generator input | |
Input voltage | Single phase 220V(-15%~30%) |
Output Specification | |
Rated output voltage | 3PH 220V |
Output frequency | 0~500.00Hz (default: 0~50.00Hz) |
380V Solar Pumping Inverter | |
Input Specification | |
PV input | |
Maxiumum input DC voltage | 800V DC |
Recommended MPPT voltage range | 450~650V DC |
Recommended input Operation voltage | 540V DC |
Grid or backup generator input | |
Input voltage | Three phase 380V(-15%~30%) |
Output specification | |
Rated ouput voltage | 3PH 380V |
Output frequency | 0~500.00Hz (default: 0~50.00Hz) |
Protection | |
Built-in Protection | Lighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc. |
General Parameters | |
Application site | No direct sunshine, no dust,corrosive gas,combustible gas, oil mist, steam,dripping or salinity etc. |
Altitude | 0~2000m |
Derated use above 1000m, per 100m, the rated output current decrease 1% | |
Environment Temperature | -10°C~40°C (Environment Temperature be 40°C~50°C, please keep derated use) |
Humidity | 5~95%, non-condensation |
Vibration | less than 5.9 m/s²(0.6G) |
Storage Temperature | -20°C~+70°C |
Efficiency | Rated Power Run≥93% |
Installation | Wall or rail mounting |
Protectiion Grade | IP20 |
Cooling | Forced Air Cooling |
1. GPRS (support 2g/3g/4g internet)
2. Output reactor
3. LCD keypad
Model Range
Drive Model | Related Voltage | Max DC input voltage (V) | Rated output current (A) | Applicable water pump (KW) | SIZE |
VFD500M-20T00150-PV | 220V | 800 | 7 | 1.5 | SIZE A |
VFD500M-20T00220-PV | 220V | 800 | 10.6 | 2.2 | SIZE A |
VFD500M-40T00150-PV | 380V | 800 | 4.2 | 1.5 | SIZE A |
VFD500M-40T00220-PV | 380V | 800 | 6 | 2.2 | SIZE A |
VFD500-20T00150-PV | 220V | 800 | 7 | 1.5 | SIZE A |
VFD500-20T00220-PV | 220V | 800 | 10.6 | 2.2 | SIZE A |
VFD500-20T00400-PV | 220V | 800 | 17 | 4 | SIZE A |
VFD500-40T00150-PV | 380V | 800 | 4.2 | 1.5 | SIZE A |
VFD500-40T00220-PV | 380V | 800 | 6 | 2.2 | SIZE A |
VFD500-40T00400-PV | 380V | 800 | 9.4 | 4 | SIZE A |
VFD500-40T00550-PV | 380V | 800 | 13 | 5.5 | SIZE B |
VFD500-40T00750-PV | 380V | 800 | 17 | 7.5 | SIZE B |
VFD500-40T01100-PV | 380V | 800 | 25 | 11 | SIZE C |
VFD500-40T01500-PV | 380V | 800 | 32 | 15 | SIZE C |
VFD500-40T01850-PV | 380V | 800 | 38 | 18.5 | SIZE D |
VFD500-40T02200-PV | 380V | 800 | 46 | 22 | SIZE D |
VFD500-40T03000-PV | 380V | 800 | 60 | 30 | SIZE E |
VFD500-40T03700-PV | 380V | 800 | 75 | 37 | SIZE E |
VFD500-40T04500-PV | 380V | 800 | 96 | 45 | SIZE F |
VFD500-40T05500-PV | 380V | 800 | 112 | 55 | SIZE F |
VFD500-40T07500-PV | 380V | 800 | 150 | 75 | SIZE G |
VFD500-40T09000-PV | 380V | 800 | 176 | 90 | SIZE G |
VFD500-40T11000-PV | 380V | 800 | 210 | 110 | SIZE H |
VFD500-40T13200-PV | 380V | 800 | 253 | 132 | SIZE I |
VFD500-40T16000-PV | 380V | 800 | 304 | 160 | SIZE I |
VFD500-40T18500-PV | 380V | 800 | 340 | 185 | SIZE J |
VFD500-40T20000-PV | 380V | 800 | 377 | 200 | SIZE J |
6. How to make the water pump system work without sunshine?
Usually, solar PV water pump system can meet the needs of pumping water.
If there is no sunshine, the system will not work. But out inverter could also support AC input. So, connect the power grid or diesel power generation to the inverter, the pumping system will work. If necessary, keep switch and interface locations during the system design
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2013
Total Annual:
15000000-20000000
Employee Number:
201~500
Ecer Certification:
Verified Supplier
Shenzhen VEIKONG Electric CO.,Ltd. a high-tech enterprise which has been specializing in researching, manufacturing and trading high, medium and low voltage inverter, providing our clients with integrated system solutions. We have professional R&D and devoted management team with more than 20 ye... Shenzhen VEIKONG Electric CO.,Ltd. a high-tech enterprise which has been specializing in researching, manufacturing and trading high, medium and low voltage inverter, providing our clients with integrated system solutions. We have professional R&D and devoted management team with more than 20 ye...