Payment Terms | L/C, T/T, Western Union |
Supply Ability | 15000pcs per Month |
Delivery Time | 3 days, depend on the order quantity |
Packaging Details | the power less than 45kw use Carton, starting from 45kw use Wooden case |
Product Name | solar pump controller |
Output type | single phase or three Phase |
Output power | 11kw 15kw 18.5kw |
Warranty | 18 monthes |
OEM | YES |
Frequency | 50/60hz |
Brand Name | VEIKONG |
Model Number | VFD500-PV |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Small Size 220V 1.5KW 2.2KW Solar Water Pump Controller For Agriculture
Automatic Switching Solar Water Pump Controller 380V 7.5kw 10hp MPPT Inverter
IP21 380V MPPT Solar Water Pump Controller 60hp 45kw solar inverter
Remote Control 180hp 132KW Off Grid Solar Pump Inverter Built In MPPT
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 15000pcs per Month |
Delivery Time | 3 days, depend on the order quantity | Packaging Details | the power less than 45kw use Carton, starting from 45kw use Wooden case |
Product Name | solar pump controller | Output type | single phase or three Phase |
Output power | 11kw 15kw 18.5kw | Warranty | 18 monthes |
OEM | YES | Frequency | 50/60hz |
Brand Name | VEIKONG | Model Number | VFD500-PV |
Certification | CE | Place of Origin | China |
High Light | IP65 Solar Pump Controller ,18.5kw Solar Pump Controller ,11kw Solar Pump Control Box |
IP20 IP65 Solar Pump Controller 11kw 15kw 18.5kw MPPT Algorithm
Electrical Specifications and Power degree
220V | 380V | |
Max input DC voltage | 450V | 810V |
DC voltage range | 150~450VDC | 300~810VDC |
Normal working DC voltage | 260V-400V | 400V-650V |
Recommended input mppt voltage | 330V | 550V |
MPPT efficiency | >99% | |
Rated output voltage | 1/3-phase 220VAC | 3-phase 380-480VAC |
Output frequency range | 50/60Hz | |
Max efficiency of the machine | 99% | |
Power range | 220v 0.75kw to 75kw, 380v 1.5kw-160kw | |
Cooling method | Air cooling | |
Protection degree | IP20/IP65 | |
Altitude | Below 1000m; above 1% for every additional 100m. | |
Standard | CE/ROHS |
Noted: We suggest solar panel power should be 1.3-1.4 times higher than solar pump power ,
And solar pump inverter power should be higher level than solar pump.
When solar pump distance to inverter higher than 100m,
It should be equipped with Output reactor or higher level power inverter.
For Solar panel,total VOC less than Maximum DC voltage of inverter and Solar panel vmp is recommend
530V for 380V pump and 305V for 220V pump.
VEIKONG VFD500-PV solar pump inverter Features:
1. A solar water pump system is essentially an electrical pump system in which the electricity is provided by one or several PhotoVoltaic (PV) panels. A typical solar powered pumping system consists of a solar panel array that powers an electric motor, which in turn powers a bore or surface pump.
2. What is solar pump inverter?
A solar inverter or PV inverter,solar pump inverter,solar pump controller,solar water pump inverter,solar pump drive,solar water pump controller,solar mppt vfd,solar mppt frequency inverter,solar frequency inverter,solar pump vsd,solar frequency inverter,solar vfd are all key words
IT is a type of electrical converter which converts the variable direct current (DC) output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be fed into a commercial electrical grid or used by a local, off-grid electrical network.
It is able to convert DC voltage coming from solar panels into AC voltage for powering any pump driven by a three-phase motor.
Pump speed is constantly adapted to available solar irradiation thus maximising the amount of pumped water and making possible operation even in conditions of low sunlight.
It also offers complete pump protection against surges, overloads and dry running.
R&D test: test the hardware and software performance, to make the design more optimization, makes sure the products have excellent
performance before production;
Board test: test the performance of every board in our products, to reduce product defective rate;
IQC: take strict quality inspection for every income components, to ensure every income components are qualified.
Aging test: make the solar pump VFDs at run status, put them in the aging test house at 50°C for 48 hours, to remove every unqualified products.
Load test: the last and the most important test, add different load to the solar pump VFDs, test their input and output value, to check their
working performance. unqualified products will be removed from the team.
By applying such strict testing process, VEIKONG ensures every outgoing solar pump VFD has excellent quality.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2013
Total Annual:
15000000-20000000
Employee Number:
201~500
Ecer Certification:
Verified Supplier
Shenzhen VEIKONG Electric CO.,Ltd. a high-tech enterprise which has been specializing in researching, manufacturing and trading high, medium and low voltage inverter, providing our clients with integrated system solutions. We have professional R&D and devoted management team with more than 20 ye... Shenzhen VEIKONG Electric CO.,Ltd. a high-tech enterprise which has been specializing in researching, manufacturing and trading high, medium and low voltage inverter, providing our clients with integrated system solutions. We have professional R&D and devoted management team with more than 20 ye...
Get in touch with us
Leave a Message, we will call you back quickly!