Payment Terms | T/T, L/C, Western Union |
Supply Ability | 50000 pieces per year |
Delivery Time | 5-7 days for sample order, 7-15 days for mass production |
Packaging Details | Each unit in one carton |
Frequency | 50/60Hz |
Display | LED/LCD |
Max.PV open circuit array voltage | 24V for 55Vdc / 48V for 110Vdc |
Indicators | LED+LCD Display |
Operating Temperature Range | 0ºC to 40ºC |
Storage Temperature | 15ºC~60ºC |
Audible Noise | 60dB max |
Cooling | Forced air,variable speed fan |
Brand Name | CONSNANT |
Model Number | CNS110 |
Certification | CE, ISO9001, ISO14001 |
Place of Origin | Shenzhen, China |
View Detail Information
Explore similar products
6KW Peak Power Reach 18KW Solar Power Inverter With Frequency 50/60Hz ± 1%
1 - 6KW MPPT Charge Mode Solar Power Inverter With Strong Overload Capacity
8KW Pure Sine Wave Solar Power Inverter With Low Energy Consumption Features
Sine Wave Solar Power Inverter Off - Grid Solar System
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 50000 pieces per year |
Delivery Time | 5-7 days for sample order, 7-15 days for mass production | Packaging Details | Each unit in one carton |
Frequency | 50/60Hz | Display | LED/LCD |
Max.PV open circuit array voltage | 24V for 55Vdc / 48V for 110Vdc | Indicators | LED+LCD Display |
Operating Temperature Range | 0ºC to 40ºC | Storage Temperature | 15ºC~60ºC |
Audible Noise | 60dB max | Cooling | Forced air,variable speed fan |
Brand Name | CONSNANT | Model Number | CNS110 |
Certification | CE, ISO9001, ISO14001 | Place of Origin | Shenzhen, China |
High Light | solar power 3 phase inverter ,solar panel dc to ac inverter |
Hybrid Off Grid Solar Power Inverter 24V / 48V 1 - 12kw 50 / 60Hz Customized
Description:
CNS110 Series Hybrid Inverter is designed to serve as a backup power supply for AC loads. The input power of CNS110 Series hybrid inverter comes from PV system and AC grid which not only supply power to AC loads but also charge the battery bank when the power from AC grid or AC generator is present(also known as Line Mode).
In the event of the AC grid (or AC generator) outage, the AC loads can be alternatively powered by PV system(if the illumination is sufficient) and the battery bank.
Features:
1. AC/Solar Charging Off Grid Hybrid Inverter.
2. LED/LCD display, Enhanced functions setting via LCD, Man-machine intelligent design
3. Built-in 40A/60A optional MPPT solar charger controller.
4. LCD shows the solar capacity.
5. 5 stages adjustable AC charging current. AC charging also can be closed
6. AC/DC priority modes can be set.
7. Generator restart signal. (Dry contact)
8. 3 times peak power. Strong loading capacity.
9. Overload, output short-circuit protection.
System parameter :
Over-load Protection: 110%<load<150%, beeps 0.5s every 1s, and fault after 60s off the output,
Load>150%, beeps 0.5s every 1s, and fault after 20s.
Surge rating(10s): 1:3(VA)
Power Saver: Load≦25W(enabled on “P/S auto” setting of Remote comtro;)
Protections: Low battery, over charging, overload, over temp
Indicatoers: LED+LCD Display
CNS110 Series Technical Specifications:
Model | CNS110 1KW-12KW | ||
Line Mode Specification: | LV Model(1-6KW) | HV Model(1-12KW) | |
Input Voltage | Input Voltage Waveform | Sinusoidal(utility or generator) | |
Nominal Input Voltage | LV 12Vac | HV 230Vac | |
Low Line Disconnect | Normal:85Vac±4% | Normal: 184 Vac±4% | |
Wide: 80 Vac±4% | Wide: 135 Vac±4% | ||
Low Line Reconnect | Normal:95Vac±4% | Normal:194Vac±4% | |
Wide: 85 Vac±4% | Wide: 145Vac±4% | ||
High Line Disconnect | Normal:136Vac±4% | Normal:263Vac±4% | |
Wide: 140 Vac±4% | Wide: 263Vac±4% | ||
High Line Reconnect | Normal:131Vac±4% | Normal:253Vac±4% | |
Wide: 135 Vac±4% | Wide: 253 Vac±4% | ||
Max AC Input Voltage | 150V rms | 270V rms | |
Input Frequency | Nominal Input Frequency | 50Hz/60Hz(Auto detection) | |
Low Line Frequency Re-connect | 51+0.3Hz for 60Hz; 41+0.3Hz for 50Hz; | ||
Low Line Frequency Disconnect | 50+0.3Hz for 60Hz; 40+0.3Hz for 50Hz; | ||
High Line Frequency Reconnect | 64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz; | ||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz; | ||
Main Function | Output Voltage Waveform | As same as input waveform | |
Over-load Protection(SMPS load) | Air switch | ||
Output Short Circuit Protection | Air switch | ||
Max Bypass Overload Current | 40A/50A |
Battery Inverter Mode Specifications: | |||
Output | Output Voltage Waveform | Sine wave | |
Rated Output Power(KW) | LV:1-6KW | HV:1KW-12KW | |
Power Factor | 0.9~1.0 | ||
Nominal Output Voltage(V) | LV:120Vac±10% rms | HV:230 Vac±10% rms | |
Nominal Output Frequency(Hz) | 60Hz±0.3Hz 50Hz±0.3Hz | ||
DC Voltage | Nominal DC Input Voltage | 12VDC/24VDC/48VDC | |
DC Voltage Range | 10-15.5Vdc for 12V battery | ||
20-31.0 Vdc for 24V battery | |||
40-62.0 Vdc for 48V battery | |||
Low Battery Alarm | 10.5Vdc±0.3Vdc for 12V Battery | ||
21.0 Vdc±0.6Vdc for24V Battery | |||
42.0 Vdc±1.2Vdc for 48V Battery | |||
Low DC input shut-down | 10.0Vdc±0.3Vdc for 12V Battery | ||
20.0Vdc±0.6Vdc for 24V Battery | |||
40.0Vdc±1.2Vdc for 48V Battery | |||
High DC input alarm&fault | 16Vdc±0.3Vdc for 12V Battery | ||
32Vdc±0.6Vdc for 24V Battery | |||
64Vdc±1.2Vdc for 48V Battery | |||
High DC input recorvery | 15.5Vdc±0.3Vdc for 12V Battery | ||
31.0Vdc±0.6Vdc for 24V Battery | |||
62.0Vdc±1.2Vdc for 48V Battery | |||
AC Charger | Nominal Charge Current | 20A/35A/50A/70A/90A(5satges adjustable charging current) | |
Charge Current Regulation | ±5Adc | ||
Over Charge protection | Bat.V≧15.5VDC for 12V battery | ||
Bat.V≧31.0VDC for 24V battery | |||
Bat.V≧62.0VDC for48V battery | |||
Beeps 0.5s every 1s& fault after 60S | |||
Algorithm | |||
Three stage:Boost CC(Constant current stage) →Boost CV(Constant voltage stage) →Float(constant voltage stage) | |||
Solar Charger | Rated Charge Current | 40A | 60A |
Rated Charge Battery Voltage Type | 12V/24V/48V | 12V/24V | |
Max PV open Circuit array voltage | 12V for 40Vdc | ||
24V for 40Vdc | |||
48V for 110Vdc | |||
Charger Mode | MPPT | ||
PV Low Voltage Re-connect | PV≧Bat.V=3V | ||
PV Low Voltage Disconnect | PV≦Bat.V | ||
Efficiency | Efficiency | ≧97% | |
Efficiency(Battery Mode) | ≧85% | ||
Efficiency(Line Mode) | >98% | ||
Transfer Time | AC to DC | 20ms(Max) | |
DC to AC | 15ms(Max) | ||
General Specifications | Operation Temperature Range | 0℃ to 40℃ | |
Strorage Temperature | -15℃~60℃ | ||
Operation Humidity | 5% to 95%(non-condensing) | ||
Audible Noise | 60dB max | ||
Cooling | Forced air, Variable speed fan | ||
Dimension(L*W*H) | 1-3KW: 526*423*260mm 4-6KW:530*396*190mm 7-12KW:627*416*204mm | ||
Net Weight(Kg) | 1KW:21.5Kg; | 1.5KW:23.5Kg | |
3KW:30.5Kg | 4KW:32Kg | ||
5KW:36.5Kg | 6KW:40.5Kg | ||
7KW:43.5Kg | 8KW:50Kg | ||
10KW:57.5Kg | 12KW:60Kg |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2015
Employee Number:
30~50
Ecer Certification:
Active Member
Shenzhen CONSNANT Technology Co., Ltd. (simple name: CONSNANT) is a professional manufacturer engaged in research, development and production of UPS (Uninterruptible Power Supply) including the Modular UPS, Outdoor & Indoor UPS,Industrial special UPS, Low Frequency & High Frequency Onlin... Shenzhen CONSNANT Technology Co., Ltd. (simple name: CONSNANT) is a professional manufacturer engaged in research, development and production of UPS (Uninterruptible Power Supply) including the Modular UPS, Outdoor & Indoor UPS,Industrial special UPS, Low Frequency & High Frequency Onlin...