China 120kva Outdoor UPS Battery Backup 1 Hours , Industrial Lowe Frequency Ups System
China 120kva Outdoor UPS Battery Backup 1 Hours , Industrial Lowe Frequency Ups System

  1. China 120kva Outdoor UPS Battery Backup 1 Hours , Industrial Lowe Frequency Ups System

120kva Outdoor UPS Battery Backup 1 Hours , Industrial Lowe Frequency Ups System

  1. MOQ: 1units
  2. Price: USD/PCS
  3. Get Latest Price
Payment Terms T/T, Western Union
Delivery Time 25-35days
Packaging Details wooden box
Type 120kva ups power solution
Capacity 120KVA/96KW
Phase 3 phase ups online
Wave pur sinewave
Battery type and number 12VDC x 32pcs(29-32pcs adjustable)
Nominal battery voltage 384VDC(base on 32pcs batteries)
Brand Name CPSY
Model Number GP33120K
Certification CE, TLC
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Delivery Time 25-35days
Packaging Details wooden box Type 120kva ups power solution
Capacity 120KVA/96KW Phase 3 phase ups online
Wave pur sinewave Battery type and number 12VDC x 32pcs(29-32pcs adjustable)
Nominal battery voltage 384VDC(base on 32pcs batteries) Brand Name CPSY
Model Number GP33120K Certification CE, TLC
Place of Origin China
High Light outdoor uninterruptible power supplypure sine wave ups

120kva ups power solution backup 1hours, industrial ups system

 

Low Frequency Online UPS

Technical Specifications

True Online Dual Conversion UPS

Built-in Galvanic Isolation Transformer

Field Proven Rugged design for tough power conditions

State of the art technology

IGBT based SPWM technology

Excellent warranty & post warranty support

Wide range of products from 1KVA to 300KVA

Wide input range

Compact size

High performance/High efficient design

Near unity input power factor

Excellent Voltage Regulation and Transient response

User friendly comprehensive LCD display and mimic diagram

Supports all types of batteries

Extended Run Time

Generator Compatible

After Sale support available in major cities across the country

Optional Intelligent Computer Interface and SNMP

Optional Auto Bypass (Static bypass)

Optional Parallel redundancy / Static redundancy

 

Applications

Office Automation

Data Centres

Building Management

Education Institutes

Telecommunication Centres

Satellite Earth Station

CNC Machines

Banking

Defence

R and D Centres

Bio-medical Equipments

Lift and Elevators

Industrial Instrumentation

Machine Tools

Security and surveillance equipments

Colour Lab Equipment

Photo Copying Machines

Printers and Plotters

Embroidery Machines

Medical Equipments

Diagnostic/Lab Equipments

Ultra Sonic Sonography Machines

ATM Centres

 

Parameter:

Model GP3360K GP3380K GP33100K GP33120K GP33160K GP33200K
Capacity 60KVA/48KW 80KVA/72KW 100KVA/80KW 120KVA/96KW 160KVA/128KW 200KVA/160KW
INPUT
Norminal Voltage 3*380VAC/400VAC(3PH +N)
Acceptable voltage range 285VAC~475VAC
Frequency Range 50Hz/60Hz±10%
INVERTER
Norminal voltage 380V
Precision 380V±25%
Frequency 50Hz/60Hz
Waveform Pure Sine wave
Total Harmonic Distortion(THDv) ≤2% (linear load); ≤5% (non-linear load)
Phase Displacement 120°±1%(balanced load); 120°±2%(imbalances 50% of the load)
Dynamic Recovery Time 3 cycles at 90% of the static value
Admissible Overload 110% for 10min;150% for 60sec;>160% for 200ms
AdmissibleCrest Factor 3:01
Admissible Power factor 0.6~1(inductive or capacitive)
Imbalance output voltage@100% unbalanced load <1%

Current limit High overload, short circuit, RMS voltage limit, High Crest-factor Curren, Peak voltage limit
STATIC BYPASS
Type Solid state
Voltage 3*380VAC/400VAC(3PH +N)
Frequency 50Hz/60Hz
Activation Criterion Microprocessor control
Transfer time Zero
Admissible Overload 150% for 1hour;180% for 30sec;>200% for 200ms
Transfer to Bypass Immediate, for overload above160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS
Type Without Interruption
Voltage 3*400V(3PH+n)
Frequency 50Hz/60Hz
Overall Efficiency(line mode) Line mode 105%±5% ≤load,warning overload;
Battery Mode 105%±5% <load≤125%±5% Transfer to bypass and Alarming after 2 mins;
BATTERY & CHARGE
Battery type & Number 12VDC*32pcs(29~32pcs adjustable)
Normal Battery Voltage 384VDC(Based on 32pcs batteries)
Charging Method CC/CV
Charging Current Default 10A, Max.=capacity(KW)/battery voltage(real time) Default: 10A.Max.40A;5A@full load
Charging Voltage 432VDC(Based on 32pcs batteries)
Safety requirements GB4943-2001/IEC62040-1 EMC/EMI, IEC 61000-4-5 Protection surge
Noise(1m) ≤55dB
PHYSICAL
Dimension,D×W×H (mm) 821x432x1159 975×554×1286 975×554×1326 1051×705×1646
Net Weight(KGS) 365 471 573 650 760 840

 

 

Model GP33120K GP33160K GP33200K
Capacity 120KVA/96KW 160KVA/128KW 200KVA/160KW
INPUT
Norminal Voltage 3*380VAC/400VAC(3PH +N)
Acceptable voltage range 285VAC~475VAC
Frequency Range 50Hz/60Hz±10%
INVERTER    
Norminal voltage 380V
Precision 380V±25%
Frequency 50Hz/60Hz
Waveform Pure Sine wave
Total Harmonic Distortion(THDv) ≤2% (linear load); ≤5% (non-linear load)
Phase Displacement 120°±1%(balanced load); 120°±2%(imbalances 50% of the load)
Dynamic Recovery Time 3 cycles at 90% of the static value
Admissible Overload 110% for 10min;150% for 60sec;>160% for 200ms
AdmissibleCrest Factor 0.125694444
Admissible Power factor 0.6~1(inductive or capacitive)

Imbalance output voltage

@100% unbalanced load

<1%
Current limit High overload, short circuit, RMS voltage limit, High Crest-factor Curren, Peak voltage limit
STATIC BYPASS    
Type Solid state
Voltage 3*380VAC/400VAC(3PH +N)
Frequency 50Hz/60Hz
Activation Criterion Microprocessor control
Transfer time Zero
Admissible Overload 150% for 1hour;180% for 30sec;>200% for 200ms
Transfer to Bypass Immediate, for overload above160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS    
Type Without Interruption
Voltage 3*400V(3PH+n)
Frequency 50Hz/60Hz
Overall Efficiency(line mode) Line mode 105%±5% ≤load,warning overload;
Battery Mode 105%±5% <load≤125%±5% Transfer to bypass and Alarming after 2 mins;
BATTERY & CHARGE    
Battery type & Number 12VDC*32pcs(29~32pcs adjustable)
Normal Battery Voltage 384VDC(Based on 32pcs batteries)
Charging Method CC/CV
Charging Current Default 10A, Max.40A;5A@ full load
Charging Voltage 432VDC(Based on 32pcs batteries)
Safety requirements GB4943-2001/IEC62040-1 EMC/EMI, IEC 61000-4-5 Protection surge
Noise(1m) ≤55dB
PHYSICAL    
Dimension,D×W×H (mm) 975×554×1326 1051×705×1646
Net Weight(KGS) 650 760 840

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2011

  • Total Annual:

    15000000-20000000

  • Employee Number:

    100~200

  • Ecer Certification:

    Active Member

Shangyu (Shenzhen) Technology Co. Ltd   A Professional Manufacturer of Uninterruptible Power Supply Shangyu (Shenzhen) Technology Co. Ltd is a professional manufacturer of uninterruptible power supplies. We are located in Shenzhen and have a registered capital of $2.3 million and ... Shangyu (Shenzhen) Technology Co. Ltd   A Professional Manufacturer of Uninterruptible Power Supply Shangyu (Shenzhen) Technology Co. Ltd is a professional manufacturer of uninterruptible power supplies. We are located in Shenzhen and have a registered capital of $2.3 million and ...

+ Read More

Get in touch with us

  • Reach Us
  • Shangyu (Shenzhen) Technology Co. Ltd
  • 4F block A,Building 1, Senyang High Technology Park, Guangming New District, Shenzhen, China.
  • https://upsbackup-system.ecer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement