Payment Terms | T/T,Western Union |
Delivery Time | 2-4 work days |
Packaging Details | Neutral Package |
Category | high frequency linear transducer |
Description | hospital patient monitoring system |
System | horse ultrasound machine |
Warranty | 60 days after fixed |
Condition | Siemens X700 instrument hospital |
Purpose | medical care supplies |
Brand Name | Siemens |
Model Number | Siemens X700 |
View Detail Information
Explore similar products
Preirus Troubleshoot Ultrasound Machine Repair Hitachi Aloka
S2000 Color Doppler Medical Machine Repair For Startup Failure
GE Clinic Ultrasound Machine Repair
EPIQ 7 Ultrasound Machine Repair
Product Specification
Payment Terms | T/T,Western Union | Delivery Time | 2-4 work days |
Packaging Details | Neutral Package | Category | high frequency linear transducer |
Description | hospital patient monitoring system | System | horse ultrasound machine |
Warranty | 60 days after fixed | Condition | Siemens X700 instrument hospital |
Purpose | medical care supplies | Brand Name | Siemens |
Model Number | Siemens X700 | ||
High Light | Simens X700 Heart Ultrasound Machine Repair ,Linear Transducer Ultrasound Machine Repair |
The self-check before the device is used indicates that the flow sensor test fails.
Analyze the factors that cause the flow sensor test failure
1.Insufficient air source pressure does not meet the test standard;
2.The outgoing call box is faulty;
3.The gas module is faulty.
4.Internal circuit boards of the ventilator, such as PC1772 and PC1771, are faulty.
Check the air source pressure is normal, eliminate the problem of air source. Further check the outgoing box. After replacement, the power-on self-test passes, indicating that the fault is in the outgoing box.
Siemens ventilator is an integrated exhalation box, which allows high-temperature disinfection. However, high-temperature and high-pressure sterilization equipment in domestic hospitals cannot meet the sterilization level of exhalation box, so the high-temperature and high-pressure sterilization is basically abandoned in China.
If the disinfection method is not correct, it will often cause the failure of the exhalation box. The key points of cleaning and disinfecting exhalation box are as follows: First, do a good job of cleaning and disinfecting the exhalation box before sending it to the supply room for sterilization. The tubes of the exhalation box will be stained with the patient's body fluid, so the tubes of the exhalation box can be washed clean by cleaning and disinfection. The common method is to soak the tubes with diluted hypochlorous acid disinfectant, and then send them to the supply room for sterilization after cleaning and disinfection.
Secondly, after the cleaning, disinfection and sterilization work in the supply room, the exhalation box must be dried. Only the use of the dried exhalation box can ensure safety, otherwise it is very easy to damage the exhalation box.
Repair List of Featured Ultrasonic Board & Assy | |||
Brand | System | Description | Part Number |
GE | Logiq P5 | CPU mainboard | 5168431 |
GE | Logiq P6 | CPU mainboard | |
GE | Logiq E9/vivid E9 | GFI2 | 5161631 |
GE | Voluson E6/Voluson E8 | RSR | KTI301394-2/KTI196357 |
GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board | KTI300614/KTI302197-6 |
GE | Voluson S6/S8/P8 | BF64 | 5396937-2 |
GE | Voluson S6/S8/P8 | RFS board | 5364098-2/5364098-3 |
GE | Voluson S6/S10/P8 | BF192 board | 5357234 |
Aloka | Alpha 5 | mainboard | EP493700DD |
Aloka | Alpha 6 | RX Beam Former | EP555501AA |
Aloka | Alpha 6 | CW board | EP555700 |
Aloka | Alpha 6 | CPU mainboard | EP537000/EP563000 |
Aloka | Alpha 6 | TX/RX | EP555300 |
Aloka | Alpha 6/Alpha 7 | DOM | EP550000AA |
Aloka | Alpha 10 | RX Beamformer board | EP531800CE |
Aloka | Alpha 10 | wave generator Board | EP495000HH/EP495000HJ/EP495000FF |
Hitachi | F37 | TX/RS | EP557400/EP557300 |
Hitachi | F37 | mainboard | EP575700BC/EP560800 |
Aloka | F75 | USP board | EP556600 |
Aloka | F75 | Cell Board | EP558800 |
Hitachi | HI VISION Avius | RDBF board | 7513907A/7513612 |
Hitachi | Arietta 60 | CELL | EU-9160C |
Hitachi | Arietta 70 | TX | EP572300AA |
Hitachi | Arietta 70 | CELL | |
Hitachi | Noblus | CELL | |
Hitachi | Noblus | CONT-B | |
Hitachi | Ascendus | CELL | 7352830A |
Siemens | X150/G40 | BE | 10131804 |
Siemens | X300 | BE 2.0/BE 3.0/BE 7.5 | 10131990 |
Siemens | X700 | BE | 10136465 |
Siemens | X700 | RC | 10136467 |
Siemens | X700 | TI | 11014292 |
Siemens | Antares | BE | 7472421 |
Siemens | Antares | CB | 7288504 |
Siemens | S2000 | RM300 | 10852163 |
Siemens | S2000 high version/S3000 | RM301 | 10854749 |
iU22/iE33 | EMB excelsior motherboard | 453561419431/453561382231/453561419431 | |
iU22/iE33 | UMB Unified Motherboard | 453561254492/453561360251 | |
HD15 | ACB acquisition control board | 453561197145/453561197144 | |
HD15 | AIM board | 4.53561E+11 | |
CX50 | control panel | 4.53562E+11 | |
CX50 | mainboard | 453561368033/453561622163/453561495832 | |
Affiniti 70 | ACQ acquisition control board | ||
EPIQ 5/EPIQ 7 | ACQ Acquisition Module board | 453561734844/453561704246 | |
Biosound | Mylab Series | CPU mainboard | 9501361000 |
Toshiba | Aplio 300/400/500 | mainboard | PM30-38696 |
Toshiba | Aplio 500 | RX | ywm2056*a |
Toshiba | Xario 200 | TX | PM30-32732-1 |
Toshiba | Xario 200 | RX | PM30-32733-1 |
Remarks | |||
1.The repair cycle is within 3-5 days. | |||
2.Warranty after fixed:60 days. | |||
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge. | |||
4.Package price is available if repair 3 pcs or more at one time. | |||
5.Extra discount for VIP partners. | |||
6.You could have different part No.under same description. |
Company Details
Business Type:
Distributor/Wholesaler,Exporter,Trading Company,Seller
Year Established:
2014
Total Annual:
5,000,000-10,000,000
Employee Number:
50~60
Ecer Certification:
Verified Supplier
Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex... Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex...
Get in touch with us
Leave a Message, we will call you back quickly!