Payment Terms | T/T, Western Union,PayPal |
Supply Ability | 50units per month |
Delivery Time | 5-8 work days |
Packaging Details | Wooden box |
Preliminary testing force | 29.4N,tolerance±2.0% |
Testing force | 147N、294N、441N,tolerance±1.0% |
Display | LCD and LED digital tube dual screen display |
Conversion scale | HV、HB、HR |
Duration time | 1~30s |
Indication error | 0.1HR |
Maximum height of specimen | 170mm |
Power supply | AC220V/50Hz |
Dimensions | 510*212*730mm |
Main unit Weight | 80kg |
Brand Name | Mitech |
Model Number | MHRS-45A |
Certification | EN-ISO,GB,ASTM.. |
Place of Origin | Beijing China |
View Detail Information
Explore similar products
Easy Operation Digital Hardness Tester Liquid Crystal Display Mitech MHRS-150
Durable Rockwell Testing Machine , Ultrasonic Hardness Tester MHRS-150-P
LCD Display Digital Hardness Tester Stable Performance Cantilever Tester MHRS
Automatic Rockwell Hardness Testing Machine Touch Screen Operation Mitech MHRS
Product Specification
Payment Terms | T/T, Western Union,PayPal | Supply Ability | 50units per month |
Delivery Time | 5-8 work days | Packaging Details | Wooden box |
Preliminary testing force | 29.4N,tolerance±2.0% | Testing force | 147N、294N、441N,tolerance±1.0% |
Display | LCD and LED digital tube dual screen display | Conversion scale | HV、HB、HR |
Duration time | 1~30s | Indication error | 0.1HR |
Maximum height of specimen | 170mm | Power supply | AC220V/50Hz |
Dimensions | 510*212*730mm | Main unit Weight | 80kg |
Brand Name | Mitech | Model Number | MHRS-45A |
Certification | EN-ISO,GB,ASTM.. | Place of Origin | Beijing China |
High Light | hardness testing equipment ,hardness measuring device |
Surface LCD Mechatronics Digital Hardness Tester Rockwell Mitech MHRS-45A
Technical specifications | Technical Parameters |
Preliminary testing force | 29.4N,tolerance±2.0% |
Testing force | 147N,294N,441N,tolerance±1.0% |
Measuring range | HR15N:70-91,HR30N:42-80,HR45N:20-70, HR15T:73-93,HR30T:43-82,HR45T:12-72 |
Testing force application Mode | Automatic operation (preliminary test needs manual operation) |
Indentor specification | Diamond cone Rockwell indenter, Φ1.5875mm steel ball indenter. |
Display | LCD and LED digital tube dual screen display |
Rockwell scale | HR15N ,HR30N ,HR45N ,HR15T ,HR30T ,HR45T |
Conversion scale | HV,HB,HR |
Duration time | 1~30s |
Indication error | 0.1HR |
Maximum height of specimen | 170mm |
Distance of indenter to outer wall | 165mm |
Power supply | AC220V/50Hz |
Dimensions | 510*212*730mm |
Main unit Weight | 80kg |
Scale | Standard Hardness Range | Allowed Maximum Tolerance |
15N | 70-91HR15N | ±2HRN |
30N | 42-80HR30N | |
45N | 20-70HR45N | |
15T | 73-93HR15T | ±3HRT |
30T | 43-82HR30T | |
45T | 12-72HR45T |
Working principle
The surface rock hardness test based on the cone diameter of a cone or low-end diamond ball pushes the hardness of the sample surface. In the test, the initial police test is loaded first and the main test is loaded. After pressing the sample test surface, the main test needs to be removed according to the bending depth of the test test while maintaining the initial test test and determining the value of the surface rock hardness of the metal material you can measure.
As shown in the figure below, 0 - 0 is the situation where the diamond indenter has not yet contacted the sample. The first test test in the 1-1 indent situation is to press the depth of h1, the first test is to eliminate the surface of the sample. This is not clean, caused by the accuracy of the results of the tests. In the figure, 2-2 is the indenter situation under the total test (the test test and the main test), the depth of indentation is h2.3-3, and the indenter after removing main test force As the position of metal elastic decay produces a specific recovery, the actual pressure h3 in depth h3. The main test that causes indent plastic disagreement at h depth is h3 - h1. The value of Rockwell's hardness is determined by the size of h, and the hardness is lower because the depth is larger. On the other hand, the hardness is increasing. Press the Rockwell Surface Hardship Unit 0.001 mm. The hardness value obtained in the surface rockwell hardness value identified by the HRN symbol (T) is called.
Features
Company Details
Business Type:
Manufacturer
Year Established:
2004
Total Annual:
1000000-8000000
Employee Number:
150~200
Ecer Certification:
Active Member
Mitech CO.,LTD. located in Beijing, China and was founded in 2004 by a group of doctors and masters graduated from tsinghua or Peking University. It is a professional NDT testing manufacturer, we have our own R&D office for newest and highest technology. Over ten years, Mitech h... Mitech CO.,LTD. located in Beijing, China and was founded in 2004 by a group of doctors and masters graduated from tsinghua or Peking University. It is a professional NDT testing manufacturer, we have our own R&D office for newest and highest technology. Over ten years, Mitech h...
Get in touch with us
Leave a Message, we will call you back quickly!