China High Accuracy Ultrasonic Water Oil Milk Diesel Fuel Flow Meter
China High Accuracy Ultrasonic Water Oil Milk Diesel Fuel Flow Meter

  1. China High Accuracy Ultrasonic Water Oil Milk Diesel Fuel Flow Meter

High Accuracy Ultrasonic Water Oil Milk Diesel Fuel Flow Meter

  1. MOQ: 1 Unit
  2. Price: Negotiable
  3. Get Latest Price
Supply Ability 1000pcs/month
Packaging Details 44X33X22cm carton
Type TF1100-EC
Product Name High Accuracy Ultrasonic Water Oil Milk Diesel Fuel Flow Meter
Accuracy Reading+/- 1%
High Temp -35-200 °C
Transducer type non-invasive
Transducer Material Metal
Medium Water Oil Milk Diesel Fuel
Application Industrial Water
Place of Origin Shanghai, China (Mainland)
Brand Name Lanry
Model Number TF1100-EC
Certification CE, CPA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 1000pcs/month Packaging Details 44X33X22cm carton
Type TF1100-EC Product Name High Accuracy Ultrasonic Water Oil Milk Diesel Fuel Flow Meter
Accuracy Reading+/- 1% High Temp -35-200 °C
Transducer type non-invasive Transducer Material Metal
Medium Water Oil Milk Diesel Fuel Application Industrial Water
Place of Origin Shanghai, China (Mainland) Brand Name Lanry
Model Number TF1100-EC Certification CE, CPA
High Light clamp on ultrasonic water flow meterultrasonic fuel flow meter
High Accuracy Ultrasonic Water Oil Milk Diesel Fuel Flow Meter
 

 

TF1100-EC High Accuracy Ultrasonic Water Oil Milk Diesel Fuel Flow Meter works on the transit-time method.  The clamp-on ultrasonic sensors are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.  In addition,  its  optional  thermal energy measurement capability makes it ossible to carry out a complete analysis of thermal energy usage in any facility.
This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities.  It can also be used for the control or even for the temporary replacement of permanently installed meters.
 
Application
 

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Food industry
Metallurgy and mining applications

 

Features
1. Non-invasive transducers are easy to install, cost effective, and require no pipe cutting or processing interrupt.
2. Wide liquid temperature range: -35℃~200℃.
3. Data logger function for this fixed flow meter .
4. Thermal energy measurement capability can be optional.
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

6. Wide bi-directional flow range of 0.01 m/s to 12 m/s..

 

 

Specifications: Transmitter

 

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V DC: 24V/500mA
Enclosure type Wall-mounted
Degree of protection IP66 according to EN60529
Operating temperature -10℃ to +60℃
Housing material Fiberglass
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Thermal energy unit GJ,KWh can be optional
Communication 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger
Security Keypad lockout, system lockout
Size 244*196*114mm
Weight 2.4kg
 
 
 

Specifications: Transducer

 

Degree of protection IP65 according to EN60529.(IP67 or IP68 Upon request)
Suited Liquid Temperature Std. Temp.: -35℃~85℃ for short periods up to 120℃
High Temp.: -35℃~200℃ for short periods up to 250℃
Pipe diameter range 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Transducer Size Type S 48(h)*28(w)*28(d)mm
Type M 60(h)*34(w)*32(d)mm
Type L 80(h)*40(w)*42(d)mm
Material of transducer Aluminum for standard temp. sensor, and peek for high temp. sensor
Cable Length Std:10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2003

  • Total Annual:

    3000000-8000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Site Member

Lanry Instruments, is the professional manufacturer of flow measure instruments, provides one package service of research and development, production, marking and after-sales servica. Engaged in the production of flow meters more than 20 years, Lanry has been equipped with advanced design capabiliti... Lanry Instruments, is the professional manufacturer of flow measure instruments, provides one package service of research and development, production, marking and after-sales servica. Engaged in the production of flow meters more than 20 years, Lanry has been equipped with advanced design capabiliti...

+ Read More

Get in touch with us

  • Reach Us
  • Lanry Instruments (Shanghai) Co., Ltd.
  • 8 Floor, Block C, Bldg 5, No.2800 Jiuxin Rd., Songjiang District, Shanghai,201612, China
  • https://www.ultraflowmeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement