Supply Ability | 1000 Unit/Units per Week 4-20mA ultrasonic flow meter for water management for OEM |
Packaging Details | packing: 1unit/carton |
Product Name | Insertion Ultrasonic Flowmeter |
Accuracy | Reading+/- 1% |
High Temp | -35-150 °C |
Transducer type | wet type |
Output | datalogger/4-20mA |
Transducer Material | stainless steel |
Power supply | 85~265VAC |
Pipe diameter | DN65-6000 |
Brand Name | Lanry |
Model Number | TF1100-EI |
Certification | CE, CMC |
Place of Origin | Shanghai, China (Mainland) |
View Detail Information
Explore similar products
Insertion Ultrasonic Flow Measurement Devices
RS485 Modbus Insertion Transit Time Ultrasonic Flow Meter
High Flow Rate Insertion Doppler Ultrasonic Flow Meter
OCT Doppler Ultrasonic Flow Meter DF6100-EI
Product Specification
Supply Ability | 1000 Unit/Units per Week 4-20mA ultrasonic flow meter for water management for OEM | Packaging Details | packing: 1unit/carton |
Product Name | Insertion Ultrasonic Flowmeter | Accuracy | Reading+/- 1% |
High Temp | -35-150 °C | Transducer type | wet type |
Output | datalogger/4-20mA | Transducer Material | stainless steel |
Power supply | 85~265VAC | Pipe diameter | DN65-6000 |
Brand Name | Lanry | Model Number | TF1100-EI |
Certification | CE, CMC | Place of Origin | Shanghai, China (Mainland) |
High Light | insertion ultrasonic flowmeter ,digital ultrasonic flow meter |
Insertion Ultrasonic Flowmeter Hot-Tapped installation with data logger
Features:
Hot-tapped installation, no pipe line flow interrupted.
No moving parts, no pressure drop, no maintenance.
Spool-piece transducer for best accuracy and better long-term stability.
High temp. Insertion transducers are suitable for high temperature of -35℃~150℃.
Wide bi-directional Flow range of 0.03 to 36 m/s, and wide range of pipe sizes from DN65 to DN6000.
Data logger function.
The heat measurement function by configuring with paired temperature sensors
The Insertion Ultrasonic Flow Meter provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
Application:
Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.
Specifications: Transmitter
Measure principle | Ultrasonic transit-time difference correlation principle |
Flow velocity range | 0.01 to 12 m/s, bi-directional |
Resolution | 0.25mm/s |
Repeatability | 0.2% of reading |
Accuracy | ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s |
Response time | 0.5s |
Sensitivity | 0.003m/s |
Damping of displayed value | 0-99s(selectable by user) |
Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
Power Supply | AC: 85-265V DC: 24V/500mA |
Enclosure type | Wall-mounted |
Degree of protection | IP66 according to EN60529 |
Operating temperature | -20℃ to +60℃ |
Housing material | Fiberglass |
Display | 4 line×16 English letters LCD graphic display, backlit |
Units | User Configured (English and Metric) |
Rate | Rate and Velocity Display |
Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
Thermal energy | unit GJ,KWh can be optional |
Communication | 4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data |
Security | Keypad lockout, system lockout |
Size | 244*196*144mm |
Weight | 2.4kg |
Data sheet download TF1100-EI transit-time insertion ultrasonic flowm...
Manual Download TF-1100-EC&EI heat meter Manual.pdf
Specifications: Transducer
PI class | IP67 or IP68 according to EN60529 |
Suited Liquid Temperature | Std. Temp.: -35℃~85℃ |
High Temp.: -35℃~150℃ | |
Pipe diameter range | DN65-6000 |
Transducer Size | Type S Φ58*199mm |
Material of transducer | Stainless Steel |
Cable Length | Std: 10m |
Temperature Sensor | Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1% |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2003
Total Annual:
3000000-8000000
Employee Number:
50~100
Ecer Certification:
Site Member
Lanry Instruments, is the professional manufacturer of flow measure instruments, provides one package service of research and development, production, marking and after-sales servica. Engaged in the production of flow meters more than 20 years, Lanry has been equipped with advanced design capabiliti... Lanry Instruments, is the professional manufacturer of flow measure instruments, provides one package service of research and development, production, marking and after-sales servica. Engaged in the production of flow meters more than 20 years, Lanry has been equipped with advanced design capabiliti...