Packaging Details | Carton package |
Supply Ability | 1000 unit per week |
Delivery Time | 7-10 days after 100% advance payment |
Product Name | DOF6000-P Portable Open Channel Ultrasonic Flow Meter |
Output | Pulse,4-20mA(Flow&Depth), RS485/Modbus,Datalogger, GPRS |
Operating Temp | 0-60 °C |
data logger | 16GB |
Degree of Protection | IP68 |
Power Supply | 50 hours Batterty |
Brand Name | LANRY |
Model Number | DOF6000-P |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
RS485 MODBUS IP68 Doppler Flow Meter
16GB Data Storage Open Channel Flow Meter
Partially Filled Pipe Doppler Flow Meter
Wall Mounted Modbus Ultrasonic Open Channel Flow Meter
Product Specification
Packaging Details | Carton package | Supply Ability | 1000 unit per week |
Delivery Time | 7-10 days after 100% advance payment | Product Name | DOF6000-P Portable Open Channel Ultrasonic Flow Meter |
Output | Pulse,4-20mA(Flow&Depth), RS485/Modbus,Datalogger, GPRS | Operating Temp | 0-60 °C |
data logger | 16GB | Degree of Protection | IP68 |
Power Supply | 50 hours Batterty | Brand Name | LANRY |
Model Number | DOF6000-P | Certification | CE |
Place of Origin | China | ||
High Light | open channel flow measurement devices ,open channel water flow meter |
Product Description
DOF6000-P Portable Open Channel Ultrasonic Flow MeterThe DOF6000 series DOF6000-P Portable Open Channel Ultrasonic Flow Meter consists of Flow calculator and the Ultraflow QSD 6537 Sensor. The Ultraflow QSD 6537 Sensor DOF6000-P Portable Open Channel Ultrasonic Flow Meter is used to measure water velocity, depth, and conductivity of water flowing in rivers, streams, open channels and pipes. When used with a companion Lanry DOF6000 Calculator, flow rate and total flow can also be calculated. The flow calculator can calculate the cross-sectional area of partially filled pipe, open channel stream or river, for stream or river, with up to 20 coordinate points describing the river’s shape of cross section. It is suitable for various applications.
| ![]() |
Doppler Open Channel Flow Meter's Features
Doppler Open Channel Flow Meter's Features
u 20 coordinate points to describe cross section of the river’s shape.
u One instrument can measure the velocity, depth and conductivity simultaneously.
u Velocity Range: 0.02mm/s to 12m/s bi-directional, accuracy is 1%.
u Depth Range: 0 to 10m.
u Measure velocity in both forward flow and back flow.
u Depth is measured by both the pressure sensor and ultrasonic level sensor principles.
u With barometric pressure compensation function.
u IP68 Epoxy-sealed body design, designed for under water installation.
u RS485/MODBUS output, can connect to computer directly.
Specifications of Doppler Open Channel Flow Meter
Specification: Calculation
Type: | Portable |
Power supply: | Calculator:85-265VAC (Charging battery) |
IP class: | Calculator: IP66 |
Operating temperature: | 0℃ ~+60℃ |
Case material: | Fiber Glass |
Display: | 4.5” color LCD |
Output: | Pulse,4-20mA(Flow & Depth),RS485/Modbus, Datalogger, GPRS |
Size: | 270L×215W×175H (mm) |
Weight: | 2.4 kg |
Data storage: | 16GB |
Application: | Partially Filled Pipe: 150-6000mm; Channel: width >200mm |
Specification: Sensor
Velocity: | Velocity range: | 20mm/s-0.8m/s; 20mm/s-1.6m/s; 20mm/s-3.2m/s (default); 20mm/s- 6.4m/s; 20mm/s-13.2m/s Bidirectional velocity capability |
Velocity accuracy: | ±1% R | |
Velocity resolution: | 1mm/s | |
Depth (Ultrasonic): | Range: | 20mm - 5000mm (5m) |
Accuracy: | ± 1mm | |
Resolution: | 1 mm | |
Depth (Pressure): | Range: | 0mm to 10000mm (10m) |
Accuracy: | ±2mm | |
Resolution: | 1 mm | |
Temperature: | Range: | 0°C - 60°C |
Accuracy: | ±0.5°C | |
Resolution: | 0.1°C | |
Electrical Conductivity (EC): | Range: | 0 to 200,000 µS/cm, Typically ± 1% of measurement |
Accuracy: | ±1% R | |
Resolution: | ±1 µS/cm | |
recorded as a 16-bit value (0 to 65,535 µS/cm) or a 32-bit value (0 to 262,143 µS/cm) | ||
Tilt (accelerometer): | Range: | ±70° in roll and pitch axes. |
Accuracy: | ±1° for angles less than 45° | |
Output: | SDI-12: | SDI-12 v1.3, Max. cable 50m |
RS485: | Modbus RTU, Max. cable 500m | |
Environmental: | Operating temperature: | 0℃ ~+60℃ water temperature |
Storage temperature: | -20℃ ~+60℃ | |
IP class: | IP68 | |
Others: | Cable: | The standard cable is 15m, the maximum option is 500m. |
Sensor material: | Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket | |
Sensor size: | 135mm x 50mm x 20mm (L x W x H) | |
Sensor weight: | 1kg with 15m of cable |
Installation of Doppler Open Channel Flow Meter
Application of Doppler Open Channel Flow Meter
Certifications
With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
High Accuracy Low Cost Wall Mount Flow Meter standard meter: 3-7 days
Special meter: pls contact us
Express, by air, by sea can be optional.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2003
Total Annual:
3000000-8000000
Employee Number:
50~100
Ecer Certification:
Site Member
Lanry Instruments, is the professional manufacturer of flow measure instruments, provides one package service of research and development, production, marking and after-sales servica. Engaged in the production of flow meters more than 20 years, Lanry has been equipped with advanced design capabiliti... Lanry Instruments, is the professional manufacturer of flow measure instruments, provides one package service of research and development, production, marking and after-sales servica. Engaged in the production of flow meters more than 20 years, Lanry has been equipped with advanced design capabiliti...