China 100ka Lightning Surge Protector 3 Poles For Telecommunications
China 100ka Lightning Surge Protector 3 Poles For Telecommunications

  1. China 100ka Lightning Surge Protector 3 Poles For Telecommunications

100ka Lightning Surge Protector 3 Poles For Telecommunications

  1. MOQ: 200 piece
  2. Price: Negotiate
  3. Get Latest Price
Payment Terms T/T, L/C, Western Union
Supply Ability 60000 pieces per month
Delivery Time 5-15 days after payment
Packaging Details export package / Negotiate
Name Surge Protector
Poles Number 3P
Uc 255/275/320/385VAC
Limp 15KA
In 60KA
Imax 100KA
Up 2,5kv
Safety Standards IEC61643-1
Connections TT/TN
Protection modes L/N
CertificationCE,CQC CE / CQC / SGS
Usage Low Voltage
Brand Name Uchi
Model Number OBV10-I-15
Certification CE / SGS / ISO9001
Place of Origin Dongguan China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, Western Union Supply Ability 60000 pieces per month
Delivery Time 5-15 days after payment Packaging Details export package / Negotiate
Name Surge Protector Poles Number 3P
Uc 255/275/320/385VAC Limp 15KA
In 60KA Imax 100KA
Up 2,5kv Safety Standards IEC61643-1
Connections TT/TN Protection modes L/N
CertificationCE,CQC CE / CQC / SGS Usage Low Voltage
Brand Name Uchi Model Number OBV10-I-15
Certification CE / SGS / ISO9001 Place of Origin Dongguan China
High Light 100ka Lightning Surge ProtectorLightning Surge Protector 3 PoleLightning Surge Protector For Telecommunications

100ka KA Power Surge Protector , Electrical Lightning Surge Protection Devicee
 

OBV10-I-15

 

Heavy duty AC Surge Protection Device (SPD) for high risk, low tolerance electrical service entrance applications. The OBV10-I-15 provides protection against the direct and indirect effects of lightning and is particularly useful in a high lightning area where the risk of heavy surge current or even direct strike is high, i.e. buildings equipped with lightning rods.

 

Surge protectors OBV10-I-15 meet the type 1 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions.The voltage-limiting,high-performance spark gaps provide several benefits.A short response time, a low protection level and high current leakage capability with long service life.

 

* Connectable lightning current and surge arrestors
* High arresting capacity up to 15 kA (10/350μs) per pole
* Combination arrestors for buildings with lightning protection system
* Simple standard hat rail mounting
* Labelled connections
* Usable in systems with lightning protection class 1-4


Technical Parameters

 

Model: OBV10-I-15-Pluggable
Maximum continuous operating voltage Uc V 255/275/320/385
SPD to EN 61643-11     Type 1
SPD to IEC 61643-1     class I
LPZ     0→2
Lightning impulse current (10/350μs) Iimp kA 15
Lightning impulse current (10/350μs) [total]   kA 60
Nominal discharge surge current (8/20μs) In kA 60
Maximum discharge surge current (8/20μs) Imax kA 100
Voltage protection level Up kV 2,5
Response time tA ns <25
Follow current quenching capacity Ipeak Ifi peak kA 12.5
Maximum back-up fuse   A 315
Temperature range ϑ °C -40℃~+85℃
Protection rating     IP 20
Connection cross-section, rigid   mm² 10-50
Connection cross-section, multi-wire   mm² 10-35
Connection cross-section, flexible   mm² 10-25
 

Feature
 

• Protection class: Type 1, Class I.
• Pole number: 3P.
• Comply with IEC standards.
• Green window will change when fault.
• High performance varistor with thermal disconnection tripping device.
• Plug-in module/base designs facilitate replacement of a failed module without the need to
• remove system wiring etc.
• Designed to protect 3 phase TN-C systems.

 
Application

 

●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers

 
Note: The system lightning protection does not guarantee that the equipment will not be 100% damaged by lightning; the power system must be multi-level lightning protection;
The complete lightning protection system includes external lightning protection and internal lightning protection. External lightning protection refers to: lightning receptors, down conductors, and grounding bodies, which are mainly used to defend against direct lightning strikes. Internal lightning protection includes: shielding, reasonable wiring, safe distance, equipotential connection, overvoltage protection, etc., mainly used to prevent lightning induction, ground potential counterattack, lightning wave intrusion, etc.
 

Others


Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No. Rated Voltage(V) Un Continuous Voltage Uc(V~) Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~) Response Time(ns)
DGM1(2)-D5 220/380

275/320
385/420

5 10 1.2 ≤25
DGM1(2)-D10 10 2 1.6
DGM1(2)-C20 20 40 1.8
DGM13-B30 30 60 .2.2
DGM3(4)-B40 10 80 2.4
DGM(4)-B60 60 100 2.8
DGM-N-PE 220/255 40/60 60/80 1.2 ≤100

 
Tip:How can we distinguish the quality of the lightning arrester?

1. It can be seen from the reaction time: determine whether the lightning arrester can respond in time and quickly discharge the lightning current.

2. It can be seen from the insertion loss: this refers to the installation of a lightning protector, the impact of this lightning protector on the line, the smaller the better

3. It can be seen from the number of impact resistance: determines the service life of the lightning arrester. Generally, the gas discharge tube will not drop after being placed for a period of time. If you want to check its quality, you can use an adjustable high-voltage DC power supply to test .

 

What skills should lightning protectors have in the selection?
 
1.Confirm power supply system
First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
 
2.Know the main parameters of the lightning arrester.
 
FAQ

 
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
 
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
 
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
 
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2006

  • Total Annual:

    1,500,000-2,500,000

  • Employee Number:

    138~168

  • Ecer Certification:

    Verified Supplier

Uchi was established in 2006 in Dongguan, China.  After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ... Uchi was established in 2006 in Dongguan, China.  After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ...

+ Read More

Get in touch with us

  • Reach Us
  • Guangdong Uchi Electronics Co.,Ltd
  • Room 810, Unit 2, Building 5, Huixing Commercial Center, Dongsheng Road No.1, Zhongshan Dong, Shilong Town Dongguan, GUANGDONG, 523326 CN
  • https://www.uchidg.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement