China factories

China factory - Guangdong Uchi Electronics Co.,Ltd

Guangdong Uchi Electronics Co.,Ltd

  • China,Dongguan ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Imax 40KA Single Phase Type 2 Surge Protector With Visual Indicator
China Imax 40KA Single Phase Type 2 Surge Protector With Visual Indicator

  1. China Imax 40KA Single Phase Type 2 Surge Protector With Visual Indicator

Imax 40KA Single Phase Type 2 Surge Protector With Visual Indicator

  1. MOQ: 200 piece
  2. Price: Negotiate
  3. Get Latest Price
Payment Terms T/T, L/C, Western Union
Supply Ability 60000 pieces per month
Delivery Time 5-15 days after payment
Packaging Details export package / Negotiate
Name Single Phase Spd
Color White
Size 4P: 72*90*43.5mm
Material MOV/Nylon/PBT
Imax 40KA
In 20kA
Time of response 25ns
CertificationCE,CQC CE / CQC / SGS
Brand Name Uchi
Model Number OBV5-C40
Certification CE / SGS / ISO9001
Place of Origin Dongguan China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, Western Union Supply Ability 60000 pieces per month
Delivery Time 5-15 days after payment Packaging Details export package / Negotiate
Name Single Phase Spd Color White
Size 4P: 72*90*43.5mm Material MOV/Nylon/PBT
Imax 40KA In 20kA
Time of response 25ns CertificationCE,CQC CE / CQC / SGS
Brand Name Uchi Model Number OBV5-C40
Certification CE / SGS / ISO9001 Place of Origin Dongguan China
High Light 40KA spd single phaseVisual indicator Type 2 Surge ProtectorSingle Phase Type 2 Surge Protector

20KA-40KA Single Phase Spd / Type 2 Surge Protector for Power supplies

The function of the power supply lightning protector is to protect various electrical equipment in the power system from damage caused by lightning overvoltage, operating overvoltage, and power frequency transient overvoltage. The main types of power surge protectors include protective gaps, valve-type surge protectors and zinc oxide surge protectors. The protective gap is mainly used to limit the atmospheric overvoltage, and is generally used for the protection of the power distribution system, the line and the incoming line of the substation. Valve-type lightning protection devices and zinc oxide lightning protection devices are used for the protection of substations and power plants. In 500KV and below systems, they are mainly used to limit atmospheric overvoltage. In ultra-high voltage systems, they will also be used to limit internal overvoltage or internal Back-up protection for overvoltage.


OBV5-C40


The surge arrestors OBV5-C40-LT meet the type 2 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions. The use of high-performance varistors permits a rapid response time and a low protection level, without any line follow current. If circumstances are uncertain and there is a risk of fire from an overload, the internal cut-off unit disconnects the arrestor from the mains if necessary. In addition, the QR code printed on the arrestor allows disary. In addition, the QR code printed on the arrestor allows direct access to the online installation instructions.


Technical Parameters

 

Model: OBV5-C40
Maximum continuous voltage AC Uc V 275/320/385/440
SPD to EN 61643-11     Type 2
SPD to IEC 61643-1     class II
Nominal discharge current (8/20< s) In kA 20
Maximum discharge current (8/20< s) Imax kA 40
Voltage protection level Up kV < 1,3/1,5/1,8/2,0
Response time tA ns < 25
Maximum back-up fuse   A 125
Temperature range ϑ -40℃~+85℃
Protection rating     IP 20
Max. cable cross-section flexible (fine-wire)   mm² 25
Max. cable cross-section rigid (single wire/multi-wire)   mm² 35

 
Feature&Benefits
 
1,Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715.
5,It can effectively ensure the equipments work properly.
·Easy installation or retrofit.
·Din-rail mountable.
·Fail-safe /self-protected design

Remote indicator (optional) with 3pin NO/NC contact.
·IP20 finger-safe design

Visual indicator.
 
Application


●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers

 

Necessity of lightning protection detection:

1.lightning protection detection surge protector can resist lightning disasters and ensure life safety.

The damage of lightning to buildings can only be avoided through lightning protection devices. Lightning directly hits buildings or equipment exposed to the air, and various overhead metal cables will cause equipment damage, and even more serious fires will cause people to bring damage to the equipment. Unnecessary property damage. Professional lightning protection testing companies can do professional lightning protection. The lightning protection testing is to check whether the installed lightning protection devices or structural equipment are reasonable, whether the protection conditions meet the requirements, and whether the electrical safety meets the standards. If it fails to meet the requirements, the lightning protection inspection company will promptly put forward corresponding rectification opinions;

 

2.Lightning protection device test results meet national standards.

The detection results of lightning protection devices of well-known domestic lightning protection inspection companies are based on the standards of the national professional departments, and the lightning protection inspection companies also use the relevant lightning protection technical standards and standards of the country and various departments as the measurement index. Professional lightning protection testing companies also have relatively more testing content. A series of lightning protection testing software and equipment involved in the detection process can objectively make standard judgments on lightning protection work, so the accuracy of the data results is also higher;

 

How to choose a suitable power arrester:

   When choosing lightning arresters to protect different types of equipment in an area, the following factors should be considered comprehensively:

●The intensity of thunderstorms in the area, the number of days of thunderstorms and the parameters of the maximum discharge current and the probability of occurrence;

●The value of the protected equipment;

●The level of impact resistance of the protected equipment;

●The social importance of protected equipment;

●Determine the power surge arrester with different protection voltage UP and discharge current; 

 

Others


Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No. Rated Voltage(V) Un Continuous Voltage Uc(V~) Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~) Response Time(ns)
DGM1(2)-D5 220/380

275/320
385/420

5 10 1.2 ≤25
DGM1(2)-D10 10 2 1.6
DGM1(2)-C20 20 40 1.8
DGM13-B30 30 60 .2.2
DGM3(4)-B40 10 80 2.4
DGM(4)-B60 60 100 2.8
DGM-N-PE 220/255 40/60 60/80 1.2 ≤100

 

Key parameters of power surge protector:

 

●Maximum continuous withstand voltage Uc (rms):
means that the arrester can work continuously at this voltage value without affecting its parameters as the arrester. Uc is non-linearly proportional to the protection voltage Up.


● Maximum discharge current Imax:
Use 8/20μs wave surge arrester once, the maximum discharge current that can withstand. It can be selected according to the local thunderstorm intensity Ng (or the average annual thunderstorm day Td) and environmental factors.


●Residual voltage Ur and protection voltage Up
Residual voltage Ur: Refers to the residual voltage value under the rated discharge current In.
Protection voltage Up: The protection voltage Up is related to the Uc voltage and Ur. According to the characteristics of the zinc oxide varistor, when the Uc value of the selected varistor is high, its Up and Ur will increase accordingly, such as when the discharge current is 10kA (8/20μs):
Uc=275V Ur (10kA, 8/20μs) ≤1200V
Uc=385V Ur (10kA, 8/20μs) ≤1600V
Uc=440V Ur (10kA, 8/20μs) ≤1800V

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2006

  • Total Annual:

    1,500,000-2,500,000

  • Employee Number:

    138~168

  • Ecer Certification:

    Verified Supplier

Uchi was established in 2006 in Dongguan, China.  After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ... Uchi was established in 2006 in Dongguan, China.  After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ...

+ Read More

Get in touch with us

  • Reach Us
  • Guangdong Uchi Electronics Co.,Ltd
  • Room 810, Unit 2, Building 5, Huixing Commercial Center, Dongsheng Road No.1, Zhongshan Dong, Shilong Town Dongguan, GUANGDONG, 523326 CN
  • https://www.uchidg.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement